Impact of suspended particles and enhancement techniques on ultraviolet disinfection of a secondary effluent

被引:5
|
作者
Jianling Wang
Lin Wang
Baozhen Wang
Jinsong Zhang
Qixian Zou
机构
[1] Harbin Institute of Technology,Water Pollution Control Research Center, School of Municipal and Environmental Engineering
[2] Ocean University of China,College of Environmental Science and Engineering
[3] Shenzhen Water (Group) Co.,undefined
[4] LTD.,undefined
关键词
effluent disinfection; biotoxicity; Chlorination/UV combined disinfection;
D O I
10.1007/s11802-006-0033-y
中图分类号
学科分类号
摘要
The concentration of suspended solids in the secondary effluent often varies widely, leading to frequent adjustment of the UV dosage to meet the disinfection criterion. In addition, a desired disinfection rate is difficult to achieve sometimes. The authors studied the particle size distribution, contribution of particle-associated Fecal Coliform (F.C.), and their influences on UV disinfection. A combined disinfection process (chlorination with a subsequent UV disinfection) was tested to improve the disinfection effect. The results indicated that the content of suspended solids, especially that of large particles, has a strong impact on UV disinfection efficiency; Dτ;10µm particles associated F.C. are difficult to be disinfected and are the main part of the tailings of F.C. inactivation curves. Pre-chlorination could decrease the number of particles in the secondary effluent and transform the large particles into small ones, reducing the influence of particles on UV disinfection and enhancing the resistance ability of the combined process to particle loading.
引用
收藏
页码:381 / 386
页数:5
相关论文
共 50 条
  • [21] Ultraviolet disinfection of effluent from subsurface flow constructed wetlands
    Richter, AY
    Weaver, RW
    ENVIRONMENTAL TECHNOLOGY, 2003, 24 (09) : 1175 - 1182
  • [22] Ultraviolet disinfection of filtered activated sludge effluent for reuse applications
    Braunstein, JL
    Loge, FJ
    Tchobanoglous, G
    Darby, JL
    WATER ENVIRONMENT RESEARCH, 1996, 68 (02) : 152 - 161
  • [23] Experimental Study on Secondary Effluent Disinfection with Ultrasound and Chlorine
    Li, Zifu
    Zhao, Xin
    Deng, Furong
    Jin, Xin
    Wu, Hao
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 3786 - 3791
  • [24] Impacts of ultrasound and ozone disinfection of WWTPs secondary effluent
    Zhao, Yuan
    Li, Zifu
    Zhang, Yang
    PROGRESS IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-4, 2013, 610-613 : 1735 - 1738
  • [25] Secondary effluent disinfection: PAA long term efficiency
    Antonelli, M.
    Rossi, S.
    Mezzanotte, V.
    Nurizzo, C.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (15) : 4771 - 4775
  • [26] Enhancement Efficacy of Ultraviolet and Ultrasonic on Wastewater Disinfection
    Guo, Yifei
    Song, Fengming
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [27] Pre-ozonation for dead-end microfiltration of the secondary effluent: suspended particles and membrane fouling
    Zhu, Hong Tao
    Wen, Xiang Hua
    Huang, Xia
    DESALINATION, 2008, 231 (1-3) : 166 - 174
  • [28] Pilot-scale studies of combined clarification, filtration, and ultraviolet radiation systems for disinfection of secondary municipal wastewater effluent
    Amin, M. M.
    Hashemi, H.
    Bina, B.
    Attar, H. Movahhedian
    Farrokhzadeh, H.
    Ghasemian, M.
    DESALINATION, 2010, 260 (1-3) : 70 - 78
  • [29] Effects of thiocyanate on the formation of free cyanide during chlorination and ultraviolet disinfection of publicly owned treatment works secondary effluent
    Zheng, AP
    Dzombak, DA
    Luthy, RG
    WATER ENVIRONMENT RESEARCH, 2004, 76 (03) : 205 - 212
  • [30] Ozone provides alternative for secondary effluent disinfection. I
    Nebel, C.
    Gottschling, R.D.
    Unangst, P.C.
    1976, 123 (04): : 76 - 78