Quantitative inversion time prescription for myocardial late gadolinium enhancement using T1-mapping-based synthetic inversion recovery imaging: reducing subjectivity in the estimation of inversion time

被引:0
|
作者
Sebastian Gassenmaier
Rob J. van der Geest
U. Joseph Schoepf
Pal Suranyi
Wolfgang G. Rehwald
Carlo N. De Cecco
Domenico Mastrodicasa
Moritz H. Albrecht
Domenico De Santis
Virginia W. Lesslie
Balazs Ruzsics
Akos Varga-Szemes
机构
[1] Medical University of South Carolina,Division of Cardiovascular Imaging, Department of Radiology and Radiological Science
[2] Ludwig-Maximilians-University,Department of Radiology, University Hospital
[3] Leiden University Medical Center,Department of Radiology
[4] Siemens Medical Solutions,Cardiovascular Magnetic Resonance Center
[5] Duke University Medical Center,Department of Neuroscience and Imaging, Section of Diagnostic Imaging and Therapy – Radiology Division
[6] “G. d’Annunzio” University,Department of Diagnostic and Interventional Radiology
[7] University Hospital Frankfurt,Department of Radiological Sciences, Oncology and Pathology
[8] University of Rome “Sapienza”,Department of Cardiology
[9] Royal Liverpool and Broadgreen University Hospital,undefined
来源
The International Journal of Cardiovascular Imaging | 2018年 / 34卷
关键词
Cardiovascular magnetic resonance imaging; T1-mapping; Late gadolinium enhancement; Look-Locker; Inversion recovery; Inversion time;
D O I
暂无
中图分类号
学科分类号
摘要
To develop a quantitative T1-mapping-based synthetic inversion recovery (IRsynth) approach to calculate the optimal inversion time (TI0) for late gadolinium enhancement (LGE) imaging. Prospectively enrolled patients (n = 130, 58 ± 16 years) underwent cardiac MRI on a 1.5T system including Look-Locker TI-scout (LL), modified LL IR (MOLLI)-based T1-mapping, and LGE acquisitions. Patients were randomized into two groups: LL group (TI-scout followed T1-mapping) or MOLLI group (T1-mapping followed TI-scout). In both groups, the second acquisition was used to determine the TI0 for LGE. IRsynth images were generated from T1-maps between TI = 200–400 ms in 5 ms increments. Image quality was rated on a 3-point scale and the remote/background signal intensity ratio (SIR) was calculated. In the LL group (n = 53), the TI-scout-based TI0 was significantly shorter compared to IRsynth [230 ms (219–242) vs. 280 ms (263–297), P < 0.0001]. The TI0 used for LGE was set 30–40 ms longer [261 ms (247–276), P < 0.0001] than the TI-scout-based TI0, resulting in a TI0 ~ 20 ms shorter than what was obtained by IRsynth (P = 0.0156). In the MOLLI group (n = 63), IRsynth-based TI0 was significantly longer than the TI-scout-based TI0 [298 ms (262–334) vs. 242 ms (217–267), P = 0.0313]. The quality of myocardial nulling was rated higher [2.4 (2.2–2.5) vs. 2.0 (1.8–2.1), P = 0.0042] and the remote/background SIR was found to be more optimal (1.6 [1.1–2.1] vs. 2.6 [1.8–3.3], P = 0.0256) in the MOLLI group. T1-based IRsynth selects TI0 for LGE more accurately than conventional TI-scout imaging. IRsynth improves TI0 selection by providing excellent visualization of the representative image contrast for LGE images, reducing operator dependence in LGE acquisition.
引用
收藏
页码:921 / 929
页数:8
相关论文
共 50 条
  • [21] Improved visualization of hepatic tumors in magnetic resonance-guided thermoablation using T1-inversion-recovery imaging with variable inversion time
    Kuebler, J.
    Krumm, P.
    Martirosian, P.
    Winkelmann, M. T.
    Gohla, G.
    Nikolaou, K.
    Hoffmann, R.
    EUROPEAN RADIOLOGY, 2023, 33 (10) : 7015 - 7024
  • [22] Detection of Myocardial Tissue Alterations in Hypertrophic Cardiomyopathy Using Texture Analysis of T2-Weighted Short Inversion Time Inversion Recovery Magnetic Resonance Imaging
    Amano, Yasuo
    Yanagisawa, Fumi
    Omori, Yuko
    Suzuki, Yasuyuki
    Ando, Chisato
    Yamamoto, Hiroshi
    Matsumoto, Naoya
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (03) : 341 - 345
  • [23] Evaluation of papillary myocardial infarction: incremental value of a short time inversion vs standard late enhancement imaging
    Annachiara Aldrovandi
    Stijin PJ De Ridder
    Oliver Strohm
    Myra Cocker
    Matthias Friedrich
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [24] Rapid assessment of myocardial infarct size in rodents using multi-slice inversion recovery late gadolinium enhancement CMR at 9.4T
    Price, Anthony N.
    Cheung, King K.
    Lim, Shiang Y.
    Yellon, Derek M.
    Hausenloy, Derek J.
    Lythgoe, Mark F.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2011, 13
  • [25] Enhanced viability imaging: Improved contrast in myocardial delayed enhancement using dual inversion time subtraction
    Foo, TKF
    Wolff, SD
    Gupta, SN
    Kraitchman, DL
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1484 - 1489
  • [26] Rapid assessment of myocardial infarct size in rodents using multi-slice inversion recovery late gadolinium enhancement CMR at 9.4T
    Anthony N Price
    King K Cheung
    Shiang Y Lim
    Derek M Yellon
    Derek J Hausenloy
    Mark F Lythgoe
    Journal of Cardiovascular Magnetic Resonance, 13
  • [27] Synthetic phase sensitive inversion recovery late gadolinium enhancement from post-contrast T1-mapping shows excellent agreement with conventional PSIR-LGE for diagnosing myocardial scar
    Goran Abdula
    Peder Sörensson
    Magnus Lundin
    Jannike Svedin
    Margareta Klein
    Peter Kellman
    Andreas Sigfridsson
    Martin Ugander
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [28] Accurate late gadolinium enhancement prediction by early T1-based quantitative synthetic mapping
    van Dijk, Randy
    Kuijpers, Dirkjan
    Kaandorp, Theodorus A. M.
    van Dijkman, Paul R. M.
    Vliegenthart, Rozemarijn
    van der Harst, Pim
    Oudkerk, Matthijs
    EUROPEAN RADIOLOGY, 2018, 28 (02) : 844 - 850
  • [29] Accurate late gadolinium enhancement prediction by early T1- based quantitative synthetic mapping
    Randy van Dijk
    Dirkjan Kuijpers
    Theodorus A. M. Kaandorp
    Paul R. M. van Dijkman
    Rozemarijn Vliegenthart
    Pim van der Harst
    Matthijs Oudkerk
    European Radiology, 2018, 28 : 844 - 850
  • [30] Fully Automatic Rapid inversion time (TI) Adjustment for Late Gadolinium Enhancement (LGE) Imaging Using a Pencil Beam Excitation Pulse for Single-Line T1 (SLT1) Mapping of Myocardium
    Wolfgang G Rehwald
    David C Wendell
    Elizabeth Jenista
    Han W Kim
    Michele Parker
    Yutaka Natsuaki
    Enn-Ling Chen
    Igor Klem
    Raymond Kim
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)