The correlation between cognitive performance and retinal nerve fibre layer thickness is largely explained by genetic factors

被引:0
|
作者
Eneh Jones-Odeh
Ekaterina Yonova-Doing
Edward Bloch
Katie M. Williams
Claire J. Steves
Christopher J. Hammond
机构
[1] King’s College London,Department of Twin Research and Genetic Epidemiology
[2] Ophthalmology,undefined
[3] King’s College London,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Retinal nerve fibre layer (RNFL) thickness has been associated with cognitive function but it is unclear whether RNFL thinning is secondary to cortical loss, or if the same disease process affects both. We explored whether there is phenotypic sharing between RNFL thickness and cognitive traits and whether such sharing is due to genetic factors. Detailed eye and cognitive examination were performed on 1602 twins (mean age: 56.4 years; range: 18–89) from the TwinsUK cohort. Associations between RNFL thickness and ophthalmic, cognitive and other predictors were assessed using linear regression or analysis of variance models. Heritability analyses were performed using uni- and bivariate Cholesky decomposition models. RNFL was thinner with increase in myopia and with decrease in disc area (p < 0.001). A thicker RNFL was associated with better performance on mini mental state examination (MMSE, F(5,883) = 5.8, p < 0.001) and with faster reaction time (RT, β = −0.01; p = 0.01); independent of the effects of age, refractive error and disc area (p < 0.05). RNFL thickness was highly heritable (82%) but there was low phenotypic sharing between RNFL thickness and MMSE (5%, 95% CI: 0–10%) or RT (7%, 95% CI: 1–12%). This sharing, however, was mostly due to additive genetic effects (67% and 92% of the shared variance respectively).
引用
收藏
相关论文
共 50 条
  • [41] Reading cognition from the eyes: association of retinal nerve fibre layer thickness with cognitive performance in a population-based study
    Girbardt, Johanna
    Luck, Tobias
    Kynast, Jana
    Rodriguez, Francisca S.
    Wicklein, Barbara
    Wirkner, Kerstin
    Engel, Christoph
    Girbardt, Christian
    Wang, Mengyu
    Polyakova, Maryna
    Witte, A. Veronica
    Loeffler, Markus
    Villringer, Arno
    Riedel-Heller, Steffi G.
    Schroeter, Matthias L.
    Elze, Tobias
    Rauscher, Franziska G.
    BRAIN COMMUNICATIONS, 2021, 3 (04)
  • [42] Correlation Between Spectral Domain OCT Retinal Nerve Fibre Layer Thickness and Multifocal Pattern Electroretinogram in Advanced Retinitis Pigmentosa
    Sliesoraityte, Ieva
    Troeger, Eric
    Bernd, Antje
    Kurtenbach, Anne
    Zrenner, Eberhart
    RETINAL DEGENERATIVE DISEASES, 2012, 723 : 471 - 478
  • [43] Correlation between optic disc topography and retinal nerve fibre layer measurements in glaucoma
    Magacho, L
    Marcondes, AM
    Costa, VP
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2005, 83 (03): : 322 - 327
  • [44] CORRELATION BETWEEN STRUCTURAL RETINAL NERVE FIBRE LAYER THICKNESS AND FUNCTIONAL VISUAL FIELD LOSS IN PRIMARY OPEN ANGLE GLAUCOMA
    Arun
    Sadhana, A.
    Dudala, Shankar Reddy
    BALI MEDICAL JOURNAL, 2015, 4 (01) : 28 - 31
  • [45] Correlation of visual field sensitivity and retinal nerve fibre layer thickness as measured by scanning laser polarimetry
    Garway-Heath, DF
    Greenfield, DS
    Caprioli, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U269 - U269
  • [46] Correlation of peripapillary retinal nerve fibre layer thickness measured by GDx and visual field loss in glaucoma
    Kuprjanowicz, L
    Szych, Z
    SOE 2003: XIV CONGRESS OF THE EUROPEAN SOCIETY OF OPHTHALMOLOGY, 2003, : 145 - 149
  • [47] Association between chromatic sensitivity and peripapillary retinal nerve fibre layer thickness in healthy eyes
    Perez-Carrasco, Ma Jesus
    Carballo-Alvarez, Jesus
    Puell, Maria
    ACTA OPHTHALMOLOGICA, 2024, 102
  • [48] Relation between size of optic disc and thickness of retinal nerve fibre layer in normal subjects
    Funaki, S
    Shirakashi, M
    Abe, H
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (11) : 1242 - 1245
  • [49] Reproducibility and agreement in evaluating retinal nerve fibre layer thickness between Stratus and Spectralis OCT
    Arthur, S. N.
    Smith, S. D.
    Wright, M. M.
    Grajewski, A. L.
    Wang, Q.
    Terry, J. M.
    Lee, M. S.
    EYE, 2011, 25 (02) : 192 - 200
  • [50] Reproducibility and agreement in evaluating retinal nerve fibre layer thickness between Stratus and Spectralis OCT
    S N Arthur
    S D Smith
    M M Wright
    A L Grajewski
    Q Wang
    J M Terry
    M S Lee
    Eye, 2011, 25 : 192 - 200