Development of background simulation model for commercial radiation portal monitor using Monte Carlo code

被引:0
|
作者
Hayoung Sim
Hee Seo
Hyeonjun Choi
Haneul Kim
Jaeho Jang
Jaekook Lee
机构
[1] Jeonbuk National University,Department of Applied Plasma and Quantum Beam Engineering
[2] Jeonbuk National University,Department of Quantum System Engineering
[3] Korea Institute of Nuclear Safety,Department of NORM Investigation
来源
关键词
Radiation portal monitor (RPM); Monte Carlo simulation; Site-specific background model; Calculation efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
At domestic ports and airports, radiation portal monitors (RPMs) have been installed and operated for detection of illegal radioactive materials in cargo containers. In RPM operation, however, false alarms occasionally sound due to naturally occurring radioactive materials. The alarm criterion is set based on the background count rate, which is a site-specific variable; therefore, optimization of the site-specific alarm criterion in consideration of site- and RPM-specific characteristics is essential for efficient operation of any RPM system. To this end, repetitive testing for various source conditions is required; such tests, however, are difficult to conduct, due to the 24/7 operation of airports and ports with their RPMs. Alternatively, Monte Carlo simulation could be the best option for RPM performance evaluation under various conditions for optimization of site-specific alarm criteria. In the present study, we employed iterative Monte Carlo simulations to precisely model a commercial RPM, based on which we were able to determine realistic gain and energy resolution parameters for a polyvinyl toluene (PVT)-based RPM. Background radiation contributing to RPM signals originated mainly from radioisotopes of the 238U and 232Th series as well as 40K in the soil near where the RPM was installed; therefore, the corresponding nuclide activity ratios were determined by a high-purity germanium (HPGe) detector based on the measured energy spectrum, and were then applied to the background simulation model. The simulated background spectrum showed good agreement with the RPM-measured experimental data. Additionally, to improve calculation efficiency, two methods using a simple box enclosure and surface source were evaluated, and the results showed an approximately 370-times improvement in computation time. The developed realistic Monte Carlo-based background model will contribute to developing site-specific RPM alarm criteria.
引用
收藏
页码:573 / 581
页数:8
相关论文
共 50 条
  • [21] EJUSTCO: Monte Carlo radiation transport code hybrid with ANN model for gamma-ray shielding simulation
    Joseph Konadu Boahen
    Ahmed S.G.Khalil
    Mohsen A.Hassan
    Samir A.Elsagheer Mohamed
    Nuclear Science and Techniques, 2023, 34 (09) : 159 - 180
  • [22] Validation of a commercial Monte Carlo code used for stereotactic radiosurgery and stereotactic body radiation therapy
    Milroy, D.
    Dos Santos, G.
    Seuntjens, J.
    Patrocinio, H.
    MEDICAL PHYSICS, 2012, 39 (07) : 4620 - 4620
  • [23] Monte Carlo simulation of breast imaging using synchrotron radiation
    Fitousi, N. T.
    Delis, H.
    Panayiotakis, G.
    MEDICAL PHYSICS, 2012, 39 (04) : 2069 - 2077
  • [24] Epp - A C++ EGSnrc user code for Monte Carlo simulation of radiation transport
    Cui, Congwu
    Lippuner, Jonas
    Ingleby, Harry R.
    Di Valentino, David N. M.
    Elbakri, Idris A.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [25] Comet: Development of an Unstructured Mesh Direct Simulation Monte Carlo Code on GPUs
    Zhang, Chonglin
    AIAA AVIATION FORUM AND ASCEND 2024, 2024,
  • [26] Monte Carlo simulation of the neutron monitor yield function
    Mangeard, P. -S.
    Ruffolo, D.
    Saiz, A.
    Madlee, S.
    Nutaro, T.
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2016, 121 (08) : 7435 - 7448
  • [27] Preclinical radiation internal dosimetry in the development of new radiopharmaceuticals using GATE Monte Carlo simulation
    Silva, Catherine C. O.
    Berdeguez, Mirta B. T.
    Barboza, Thiago
    Souza, Sergio A. L.
    Braz, Delson
    Silva, Ademir X.
    Sa, Lidia, V
    RADIATION PHYSICS AND CHEMISTRY, 2020, 173
  • [28] Simulation of charge breeding of rubidium using Monte Carlo charge breeding code and generalized ECRIS model
    Zhao, L.
    Cluggish, B.
    Kim, J. S.
    Pardo, R.
    Vondrasek, R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (02):
  • [29] Fluids in a Hybrid System by Using MCNPX Monte Carlo Radiation Transport Code
    Gunay, M.
    ACTA PHYSICA POLONICA A, 2015, 128 (2B) : B113 - B117
  • [30] Effects of rainfall and temperature on background signal of radiation portal monitor
    Sim, Hayoung
    Choi, Hyosang
    Baek, Seungho
    Seo, Hee
    Choi, Hyeonjun
    Kim, Haneul
    Jang, Jaeho
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (8-9) : 710 - 715