Determination of trace elements in zeolites by laser ablation ICP-MS

被引:0
|
作者
C. Pickhardt
I. B. Brenner
J. S. Becker
H.-J. Dietze
机构
[1] Zentralabteilung für Chemische Analysen,
[2] Forschungszentrum Jülich GmbH,undefined
[3] D-52425 Jülich,undefined
[4] Germany,undefined
[5] 9 Dishon Street,undefined
[6] Malkha BGU-EAL,undefined
[7] 96956 Jerusalem,undefined
[8] Israel,undefined
关键词
Zeolite; Inductively Couple Plasma Mass Spectrometry; Laser Ablation; Aluminosilicate; Trace Element Concentration;
D O I
暂无
中图分类号
学科分类号
摘要
Laser ablation inductively coupled plasma mass spectrometry using a quadrupole-based mass spectrometer (LA-ICP-QMS) was applied for the analysis of powdered zeolites (microporous aluminosilicates) used for clean-up procedures. For the quantitative determination of trace element concentrations three geological reference materials, granite NIM-G, lujavrite NIM-L and syenite NIM-S, from the National Institute for Metallurgy (South Africa) with a matrix composition corresponding to the zeolites were employed. Both the zeolites and reference materials were fused with a lithium borate mixture to increase the homogeneity and to eliminate mineralogical effects. In order to compare two different approaches for the quantification of analytical results in LA-ICP-MS relative sensitivity coefficients (RSCs) of chemical elements and calibration curves were measured using the geostandards. The experimentally obtained RSCs are in the range of 0.2-6 for all elements of interest. Calibration curves for trace elements were measured without and with Li or Ti as internal standard element. With a few exceptions the regression coefficients of the calibration curves are better than 0.993 with internal standardization. NIM-G granite reference material was employed to evaluate the accuracy of the technique. Therefore, the measured concentrations were corrected with RSCs which were determined using lujavrite reference material NIM-L. This quantification method provided analytical results with deviations of 1–11% from the recommended and proposed values in granite reference material NIM-G, except for Co, Cs, La and Tb. The relative standard deviation (RSD) of the determination of the trace element concentration (n = 5) is about 1% to 6% using Ti as internal standard element. Detection limits of LA-ICP-QMS in the lower μg/g range (from 0.03 μg/g for Lu, Ta and Th to 7.3 μg/g for Cu, with the exception of La) have been achieved for all elements of interest. Under the laser ablation conditions employed (λ: 266 nm, repetition frequency: 10 Hz, pulse energy: 10 mJ, laser power density: 6 × 109 W/cm2) fractionation effects of the determined elements relative to the internal standard element Ti were not observed.
引用
收藏
页码:79 / 87
页数:8
相关论文
共 50 条
  • [41] UTILIZATION OF ICP-AES AND ICP-MS FOR THE DETERMINATION OF TRACE-ELEMENTS IN COMPLEX MATRICES
    FRICKE, FL
    SATZGER, RD
    WOLNIK, KA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 181 - ANYL
  • [42] Comparison of ICP-OES and ICP-MS and their application to the determination of trace elements in fertilizers.
    Wallace, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 222 : U65 - U65
  • [43] Determination of trace elements in small amounts of environmental samples by ICP-MS: A review
    Becker, JS
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2002, 47 (04): : 98 - 108
  • [44] Determination of major and trace elements in Japanese rock reference samples by ICP-MS
    Yoshida, S
    Muramatsu, Y
    Tagami, K
    Uchida, S
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1996, 63 (03) : 195 - 206
  • [45] Comparison of NAA and ICP-MS for the determination of major and trace elements in environmental sample
    H. Tsukada
    A. Takeda
    H. Hasegawa
    S. Ueda
    T. Iyogi
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 263 : 773 - 778
  • [46] Determination of Trace Elements and Heavy Metals in Coconut Meat Simultaneously by ICP-MS
    Zhang, Yanbei
    Rui, Yukui
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (09) : 5105 - 5106
  • [47] Forensic applications of laser ablation ICP-MS
    Almirall, Jose
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [48] A study of sclerochronology by laser ablation ICP-MS
    Toland, H
    Perkins, B
    Pearce, N
    Keenan, F
    Leng, MJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) : 1143 - 1148
  • [49] Trace elements determination in edible seaweeds by an optimized and validated ICP-MS method
    Rodenas de la Rocha, S.
    Sanchez-Muniz, F. J.
    Gomez-Juaristi, M.
    Larrea Marin, M. T.
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2009, 22 (04) : 330 - 336
  • [50] Trace element determination in lichens by ICP-MS
    Bettinelli, M
    Spezia, S
    Bizzarri, G
    ATOMIC SPECTROSCOPY, 1996, 17 (03) : 133 - 141