The mechanics of polymer swelling on microcantilever sensors

被引:0
|
作者
Natalya L. Privorotskaya
William P. King
机构
[1] University of Illinois Urbana-Champaign,Department of Mechanical Science and Engineering
来源
Microsystem Technologies | 2009年 / 15卷
关键词
Thickness Ratio; Longitudinal Stress; Transverse Stress; Cantilever Length; Stiff Polymer;
D O I
暂无
中图分类号
学科分类号
摘要
This paper investigates the swelling mechanics of polymer capture layers integrated into piezoresistive cantilever biochemical sensors. A finite element model investigates mechanical deformations in a polymer layer affixed to a silicon microcantilever. The polymer swells during analyte absorption, inducing deformations in the silicon cantilever which are sensed by a piezoresistive sensor integrated into the cantilever. The highest sensitivity is predicted for short and wide cantilevers that are coated with stiff polymer whose thickness is twice that of the cantilever. While the polymer swelling induces the deformations, the silicon carries most of the load. When portions of the silicon beam are removed to introduce stress concentrations, the system sensitivity can increase by 18% compared to the cantilever without stress concentrations. This study of stress distributions in the cantilever system allows sensor optimization that considers the full 3D effects of polymer swelling mechanics.
引用
收藏
页码:333 / 340
页数:7
相关论文
共 50 条
  • [31] Simulation and design of piezoelectric microcantilever chemical sensors
    Zhou, W
    Khaliq, A
    Tang, YJ
    Ji, HF
    Selmic, RR
    SENSORS AND ACTUATORS A-PHYSICAL, 2005, 125 (01) : 69 - 75
  • [32] Microcantilever Array Sensors With Integrated PDMS Microfluidics
    Nordin, Gregory P.
    Anderson, Ryan R.
    Hu, Weisheng
    Ness, Stanley J.
    Richards, Danny C.
    Oxborrow, Joseph
    Gustafson, Timothy
    Tsai, Ben
    Mazzeo, Brian
    Woolley, Adam
    2011 IEEE SENSORS, 2011, : 1333 - 1336
  • [33] MICROCANTILEVER CHEMICAL SENSORS IN COMSOL MULTIPHYSICS AREA
    Kashaninia, Alireza
    Norouzi, Maziar
    ICMEE 2009: PROCEEDINGS OF THE 2009 INTERNATIONAL CONFERENCE ON MECHANICAL AND ELECTRONICS ENGINEERING, 2010, : 15 - +
  • [34] Frequency Shift of Piezoelectric Microcantilever Humidity Sensors
    Wang, Fei
    SECOND INTERNATIONAL CONFERENCE ON SMART MATERIALS AND NANOTECHNOLOGY IN ENGINEERING, 2009, 7493
  • [35] Detection of feline coronavirus using microcantilever sensors
    Velanki, Sreepriya
    Ji, Hai-Feng
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (11) : 2964 - 2968
  • [36] Design and optimization of laminated piezoresistive microcantilever sensors
    Wang, ZY
    Yue, RF
    Zhang, RX
    Liu, LT
    SENSORS AND ACTUATORS A-PHYSICAL, 2005, 120 (02) : 325 - 336
  • [37] Effect of the clad transparency condition in POF humidity sensors with the swelling polymer clad
    Kato, Shigeaki
    Morisawa, Masayuki
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [38] Aptamer Functionalized Microcantilever Sensors for Cocaine Detection
    Kang, Kyungho
    Sachan, Ashish
    Nilsen-Hamilton, Marit
    Shrotriya, Pranav
    LANGMUIR, 2011, 27 (23) : 14696 - 14702
  • [39] Chemical sensors based on funstionalized microcantilever arrays
    Datskos, P. G.
    Lavrik, N. V.
    Sepaniak, M. J.
    Dutta, P.
    2006 IEEE SENSORS, VOLS 1-3, 2006, : 862 - +
  • [40] The lithium polymer battery swelling test with high-precision displacement sensors
    Szurke, Szabolcs Kocsis
    Lakatos, Istvan
    2018 20TH INTERNATIONAL SYMPOSIUM ON ELECTRICAL APPARATUS AND TECHNOLOGIES (SIELA), 2018,