Post-yield Damping Ratio Estimation Studies for Masonry-Infilled Reinforced Concrete Frames

被引:0
|
作者
Tushar H. Bhoraniya
Sharadkumar P. Purohit
机构
[1] Nirma University,Civil Engineering Department, School of Engineering, Institute of Technology
关键词
Masonry infills; Lateral load; Displacement ductility; Maximum drift ratio; Damping ratio; Free vibration;
D O I
暂无
中图分类号
学科分类号
摘要
Damping ratio is an important and central parameter for the dynamic analysis of structures. The present study focuses on the estimation of the equivalent damping ratio in a post-yield region for RC frames, both with and without infills. One-story one-bay RC frames casted non-integrally with fly ash (FA) bricks and autoclaved aerated concrete (AAC) blocks infills are considered and are tested under monotonic lateral half-cycle loading. Post-yield behavior parameters, displacement ductility and maximum drift ratio, are used to estimate the equivalent damping ratio at each cycle of lateral loading, and empirical relationships are established. Secant stiffness and stiffness degradation for RC frames are also extracted to determine the contribution and effectiveness of type of infills. Free vibration tests on RC frame specimens are conducted subsequent to each cycle of monotonic lateral loading, and the damping ratio is evaluated. It is found that the equivalent damping ratio substantially increases for RC frames with the onset of damage in the post-yield region. The major advantage of the infilled RC frame is a drastic reduction in the maximum drift ratio. However, types of infill are found to yield equivalent damping ratio at par, suggesting similar energy dissipation capabilities. RC frame infilled with AAC block is recommended due to its higher initial as well as secant stiffness vis-a`\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\grave{a}$$\end{document}-vis FA brick-infilled RC frames and higher stiffness degradation that allows it to behave similar to RC frame without infill.
引用
收藏
页码:193 / 204
页数:11
相关论文
共 50 条
  • [41] Out-of-Plane Strengthening of Masonry-Infilled RC Frames with Textile-Reinforced Mortar Jackets
    Koutas, Lampros N.
    Bournas, Dionysios A.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2019, 23 (01)
  • [42] Influence of masonry panels with openings on the seismic response of reinforced concrete infilled frames
    Noui, S.
    Kadid, A.
    Bali, A.
    SCIENTIA IRANICA, 2019, 26 (01) : 157 - 166
  • [43] Effect of openings on the behaviour of fibre reinforced concrete and masonry infilled RC frames
    Ganesan, N.
    Irshad, P.
    Indira, P.V.
    Indian Concrete Journal, 2019, 98 (01): : 8 - 15
  • [44] A simplified method for estimating the fundamental period of masonry infilled reinforced concrete frames
    Jiang, Rui
    Jiang, Liqiang
    Hu, Yi
    Ye, Jihong
    Zhou, Lingyu
    STRUCTURAL ENGINEERING AND MECHANICS, 2020, 74 (06) : 821 - 832
  • [45] Effect of openings on the behaviour of fibre reinforced concrete and masonry infilled RC frames
    Ganesan, N.
    Irshad, P.
    Indira, P.V.
    Indian Concrete Journal, 2019, 93 (01): : 8 - 15
  • [46] Lateral stiffness of masonry infilled reinforced concrete (RC) frames with central opening
    Mondal, Goutam
    Jain, Sudhir K.
    EARTHQUAKE SPECTRA, 2008, 24 (03) : 701 - 723
  • [47] Explainable machine learning aided optimization of masonry infilled reinforced concrete frames
    Latif, Iqra
    Banerjee, Arnab
    Surana, Mitesh
    STRUCTURES, 2022, 44 : 1751 - 1766
  • [48] In-Plane Seismic Response of Autoclaved Aerated Concrete Block Masonry-Infilled Reinforced Concrete Frame Building
    Zade, Nikhil P.
    Bhosale, Avadhoot
    Sarkar, Pradip
    Davis, Robin
    ACI STRUCTURAL JOURNAL, 2022, 119 (02) : 45 - 60
  • [49] Seismic strengthening of masonry infilled reinforced concrete frames with steel-fibre-reinforced mortar
    Yaman, Tugce Sevil
    Canbay, Erdem
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2014, 167 (01) : 3 - 14
  • [50] Analytical estimation of lateral resistance of low-shear strength masonry infilled reinforced concrete frames with openings
    Mansouri, Ali
    Marefat, Mohammad Sadegh
    Khanmohammadi, Mohammad
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2018, 27 (06):