A new approach to toxicity testing in Daphnia magna: application of high throughput FT-ICR mass spectrometry metabolomics

被引:0
|
作者
Nadine S. Taylor
Ralf J. M. Weber
Andrew D. Southam
Tristan G. Payne
Olga Hrydziuszko
Theodoros N. Arvanitis
Mark R. Viant
机构
[1] University of Birmingham,School of Biosciences
[2] University of Birmingham,Centre for Systems Biology
[3] University of Birmingham,School of Electronic, Electrical & Computer Engineering
来源
Metabolomics | 2009年 / 5卷
关键词
Metabonomics; Environmental metabolomics; Water flea; Tiered testing; Risk assessment; SIM-stitching;
D O I
暂无
中图分类号
学科分类号
摘要
Currently there is a surge of interest in exploiting toxicogenomics to screen the toxicity of chemicals, enabling rapid and accurate categorisation into classes of defined mode-of-action (MOA), and prioritising chemicals for further testing. Direct infusion FT-ICR mass spectrometry-based metabolomics can provide a sensitive and unbiased analysis of metabolites in only 15 mins and therefore has considerable potential for chemical screening. The water flea, Daphnia magna, is an OECD test species and is utilised internationally for toxicity testing. However, no metabolomics studies of this species have been reported. Here we optimised and evaluated the effectiveness of FT-ICR mass spectrometry metabolomics for toxicity testing in D. magna. We confirmed that high-quality mass spectra can be recorded from as few as 30 neonates (<24 h old; 224 μg dry mass) or a single adult daphnid (301 μg dry mass). An OECD 24 h acute toxicity test was conducted with neonates at copper concentrations of 0, 5, 10, 25, 50 μg l−1. A total of 5447 unique peaks were detected reproducibly, of which 4768 were assigned at least one empirical formula and 1017 were putatively identified based upon accurate mass measurements. Significant copper-induced changes to the daphnid metabolome, consistent with the documented MOA of copper, were detected thereby validating the approach. In addition, N-acetylspermidine was putatively identified as a novel biomarker of copper toxicity. Collectively, our results highlight the excellent sensitivity, reproducibility and mass accuracy of FT-ICR mass spectrometry, and provide strong evidence for its applicability to high-throughput screening of chemical toxicity in D. magna.
引用
收藏
页码:44 / 58
页数:14
相关论文
共 50 条
  • [21] Discovery of Cisplatin Binding to Thymine and Cytosine on a Single-Stranded Oligodeoxynucleotide by High Resolution FT-ICR Mass Spectrometry
    Zeng, Wenjuan
    Zhang, Yanyan
    Zheng, Wei
    Luo, Qun
    Han, Juanjuan
    Liu, Jian'an
    Zhao, Yao
    Jia, Feifei
    Wu, Kui
    Wang, Fuyi
    MOLECULES, 2019, 24 (10):
  • [22] Oligomers, organosulfates, and nitrooxy organosulfates in rainwater identified by ultra-high resolution electrospray ionization FT-ICR mass spectrometry
    Altieri, K. E.
    Turpin, B. J.
    Seitzinger, S. P.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2009, 9 (07) : 2533 - 2542
  • [23] High field FT-ICR mass spectrometry data sets enlighten qualitative DOM alteration in lake sediment porewater profiles
    Herzsprung, Peter
    von Tuempling, Wolf
    Wendt-Potthoff, Katrin
    Hertkorn, Norbert
    Harir, Mourad
    Schmitt-Kopplin, Philippe
    Friese, Kurt
    ORGANIC GEOCHEMISTRY, 2017, 108 : 51 - 60
  • [24] Revisiting Dissolved Organic Matter Analysis Using High-Resolution Trapped Ion Mobility and FT-ICR Mass Spectrometry
    B. Oliveira, Pablo R.
    Leyva, Dennys
    Tose, Lilian V.
    Weisbrod, Chad
    Kozhinov, Anton N.
    Nagornov, Konstantin O.
    Tsybin, Yury O.
    Fernandez-Lima, Francisco
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2024, 35 (10) : 2400 - 2407
  • [25] High-field FT-ICR mass spectrometry and NMR spectroscopy to characterize DOM removal through a nanofiltration pilot plant
    Cortes-Francisco, Nuria
    Harir, Mourad
    Lucio, Marianna
    Ribera, Gemma
    Martinez-Llado, Xavier
    Rovira, Miquel
    Schmitt-Kopplin, Philipe
    Hertkorn, Norbert
    Caixach, Josep
    WATER RESEARCH, 2014, 67 : 154 - 165
  • [26] Fast Reversed-Phase Liquid Chromatography to Reduce Back Exchange and Increase Throughput in H/D Exchange Monitored by FT-ICR Mass Spectrometry
    Zhang, Hui-Min
    Bou-Assaf, George M.
    Emmett, Mark R.
    Marshall, Alan G.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (03) : 520 - 524
  • [27] HIGH-MASS RESOLUTION GLOW-DISCHARGE MASS-SPECTROMETRY USING AN EXTERNAL ION-SOURCE FT-ICR MASS-SPECTROMETER
    WATSON, CH
    WRONKA, J
    LAUKIEN, FH
    BARSHICK, CM
    EYLER, JR
    ANALYTICAL CHEMISTRY, 1993, 65 (20) : 2801 - 2804
  • [28] Ultra-High Mass Resolving Power, Mass Accuracy, and Dynamic Range MALDI Mass Spectrometry Imaging by 21-T FT-ICR MS
    Bowman, Andrew P.
    Blakney, Greg T.
    Hendrickson, Christopher L.
    Ellis, Shane R.
    Heeren, Ron M. A.
    Smith, Donald F.
    ANALYTICAL CHEMISTRY, 2020, 92 (04) : 3133 - 3142
  • [29] Direct sulfur-containing compound speciation in crude oils and high-boiling fractions by APCI (+) FT-ICR mass spectrometry
    Franco, Danielle Mitze Muller
    Covas, Taynara Rodrigues
    Pereira, Rosana Cardoso Lopes
    da Silva, Lidya Cardozo
    Rangel, Mario Duncan
    Simas, Rosineide Costa
    Dufrayer, Gabriel Henry Morais
    Vaz, Boniek Gontijo
    ANALYTICAL METHODS, 2024, 16 (17) : 2635 - 2642
  • [30] High resolution fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) for the characterisation of enzymatic processing of commercial lignin
    Echavarri-Bravo, Virginia
    Tinzl, Matthias
    Kew, Will
    Cruickshank, Faye
    Mackay, C. Logan
    Clarke, David J.
    Horsfall, Louise E.
    NEW BIOTECHNOLOGY, 2019, 52 (1-8) : 1 - 8