Effect of repetitive square voltage frequency on partial discharge features

被引:0
|
作者
Peng Wang
GuangNing Wu
Yang Luo
GuangYa Zhu
机构
[1] Southwest Jiaotong University,School of Electrical Engineering
来源
关键词
inverter-fed motors; partial discharge; insulation system; qualification test; square voltages;
D O I
暂无
中图分类号
学科分类号
摘要
The inverter-fed motor is a key component of environmental-friendly hybrid cars, high-speed trains, and other industrial applications. After the widespread use of inverter-fed motors, the repetitive impulse surges from inverters were found to cause new insulation problems in inverter-fed motors that were linked to premature insulation failure. The partial discharge (PD) induced by the overvoltage inner stator windings was found to be the root cause of insulation reliability problems. To mitigate this problem, PD detection and life testing at repetitive square voltages should be performed on new types of insulation models and entire motor insulation systems. The obtained partial discharge inception voltage (PDIV) and lifetime of insulation in the tests can be used to evaluate the insulation status of inverter-fed motor insulation systems and thus to improve the insulation designs. At AC voltage conditions, the voltage frequency can significantly affect PD activity. At repetitive square voltage with rapid rise time, the influence of the square voltage frequency on PD activity should be investigated (1) to suggest values for the repetitive square voltage frequency selection for the PDIV and lifetime tests, and (2) to increase the signal-to-noise ratio when extracting PD pulses from strong disturbances generated by the operating switch of impulse generators. Therefore, the main purpose of this paper was to investigate the effects of repetitive square voltage frequency on PD events. Insulation models of both Type I (low-voltage inverter-fed motor) and Type II (high-voltage inverter-fed motor) were used to obtain single-PD and multi-PD statistical features, respectively. Experimental results indicated that higher frequencies caused less PD events with lower PD magnitudes and shorter delay times in one square voltage cycle. This phenomenon was attributed to the different surface charge decay ratios and the initial electron emission probabilities resulting from different square voltage frequencies. Finally, a number of considerations for PD measurements on inverter-fed motors were provided to improve the sensitivity of the PD test system and to obtain high objective insulation lifetime test results, which are used to assess the insulation status of inverter-fed motors.
引用
收藏
页码:1313 / 1321
页数:8
相关论文
共 50 条
  • [41] Partial discharge characteristics of inverter-fed motor insulation at repetitive square wave voltages
    Wang, Peng
    Gao, Bo
    Wu, Guangning
    Luo, Yang
    Cao, Kaijiang
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (06): : 1522 - 1526
  • [42] Partial discharge and aging of AC cable systems under repetitive voltage transient supply
    Montanari, Gian Carlo
    Fabiani, Davide
    Ciani, Fabio
    2016 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2016, : 379 - 382
  • [43] Proposal of Noise Rejection in Automatic Measurement System of Repetitive Partial Discharge Inception Voltage
    Nishigaki, Yasutaka
    Takenouchi, Sho
    Kozako, Masahiro
    Hikita, Masayuki
    Nakamura, Takahiro
    Sun, Jintong
    Izumi, Aoto
    Sakurai, Takayuki
    Karasawa, Kazunari
    Hirose, Tatsuya
    PROCEEDINGS OF 2020 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2020), 2020, : 522 - 524
  • [44] Investigating the Effect of Frequency and Wave Shape of Voltage Source on Partial Discharge Behaviour within Cavity in Medium Voltage Cable
    Gouda, Osama
    ElFaraskoury, Adel
    ElSinary, AbdRabu
    Farag, Adel
    2017 NINETEENTH INTERNATIONAL MIDDLE-EAST POWER SYSTEMS CONFERENCE (MEPCON), 2017, : 1093 - 1099
  • [45] EFFECT OF TEMPERATURE ON THE PARTIAL DISCHARGE INITIATION VOLTAGE OF CAPACITORS
    KARADY, GG
    ROY, RR
    DOMITZ, S
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1995, 2 (03) : 499 - 502
  • [46] Effect of Applied Voltage and Electromagnetic Shielding on Partial Discharge
    Garg, Ankita
    Tiwary, Anyuti
    Basak, Prasenjit
    Paramane, Ashish
    2018 INTERNATIONAL CONFERENCE ON COMPUTING, POWER AND COMMUNICATION TECHNOLOGIES (GUCON), 2018, : 652 - 656
  • [47] Estimation of Partial Discharge Inception Voltage under Repetitive Inverter Surge Voltage by Volume-Time Theory
    Hayakawa, N.
    Daicho, Y.
    Kaji, T.
    Kojima, H.
    2018 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2018, : 550 - 553
  • [48] The limitation of partial discharge inception voltage tests at repetitive impulsive voltages using ultra-high frequency antenna and possible solutions
    Wang, Peng
    Zhou, Wanya
    Zhao, Zhengjia
    Cavallini, Andrea
    2018 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2018, : 192 - 195
  • [49] Transition of partial discharge behavior with aging under square-wave AC voltage
    Wu, Kai
    Okamoto, Tatsuki
    Suzuoki, Yasuo
    ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 36 - +
  • [50] Characteristics and Mechanism of Partial Discharge Behavior of Power Module Under Unipolar Square Voltage
    Wang, Haihua
    Xiao, Guochun
    Wang, Laili
    Yan, Feifei
    Ma, Zaojun
    Yang, Qingshou