Patient-initiated, pressure-regulated, volume-controlled ventilation compared with intermittent mandatory ventilation in neonates: a prospective, randomised study

被引:0
|
作者
A. Piotrowski
W. Sobala
P. Kawczyński
机构
[1] Intensive Care Unit,
[2] Paediatric Hospital,undefined
[3] Medical University of Łódź,undefined
[4] ul. Sporna 36/50,undefined
[5] PL-91-738 Łódź,undefined
[6] Poland,undefined
[7] Institute of Occupational Medicine,undefined
[8] Department of Epidemiology,undefined
[9] ul. Św. Teresy 8,undefined
[10] Łódź,undefined
[11] Poland,undefined
来源
Intensive Care Medicine | 1997年 / 23卷
关键词
Key words Neonate; Respiratory distress syndrome; Respiratory failure; Mechanical ventilation; Controlled clinical trial;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: To compare the effects of patient-initiated, pressure-regulated, volume-controlled ventilation (PRVC) with pressure-preset intermittent mandatory ventilation (IMV) in neonates with respiratory failure. Design: Randomised, prospective study. Setting: Intensive care unit (14 beds) in a 300-bed paediatric teaching hospital. Patients: 60 neonates with respiratory distress syndrome (RDS) or congenital pneumonia, weighing < 2500 g and requiring mechanical ventilation. Interventions: Ventilatory support until extubation via either IMV (n = 30) or PRVC (n = 27). In PRVC, the tidal volume (VT) was preset and pressure-controlled breaths delivered with peak inspiratory pressure values adapted to achieve the preset VT. Measurements and results: Main outcome measures were duration of ventilation and incidence of bronchopulmonary dysplasia (BPD). Pulmonary air leaks and intraventricular haemorrhage (IVH) were considered major adverse effects. Demographic data, ventilation parameters and arterial/alveolar oxygen tension ratio were similar at randomisation. Duration of ventilation and incidence of BPD were not decreased by the use of PRVC. Air leaks occurred in 3 neonates in the PRVC group and in 7 babies treated with IMV (NS). The incidence of IVH grade > II was lower in babies treated with PRVC (p < 0.05). In a subgroup of neonates weighing < 1000 g, the duration of ventilation and incidence of hypotension were reduced in the PRVC group (p < 0.05). Conclusion: Patient-initiated, pressure-regulated, volume-controlled ventilation can be safely used in neonates and may contribute to a lower incidence of complications.
引用
收藏
页码:975 / 981
页数:6
相关论文
共 50 条
  • [31] INTRAPULMONARY PERCUSSIVE VENTILATION SUPERIMPOSED TO CONVEN TIONAL MECHANICAL VENTILATION: COMPARISON BETWEEN VOLUME-CONTROLLED AND PRESSURE-CONTROLLED MODE, A BENCH STUDY
    Riffard, G.
    Buzenet, J.
    Guerin, C.
    INTENSIVE CARE MEDICINE, 2013, 39 : S249 - S250
  • [32] Comparison between volume-controlled ventilation and pressure-controlled volume-guaranteed ventilation in postoperative lung atelectasis using lung ultrasound following upper abdominal laparotomies: a prospective randomized study
    Bahaa El-din Ewees Hassan
    Ahmed Nagah El-Shaer
    Marwa Ahmed Khairy Elbeialy
    Shimaa Ahmed Mohamed Ismail
    Ain-Shams Journal of Anesthesiology, 12
  • [33] Comparison between volume-controlled ventilation and pressure-controlled volume-guaranteed ventilation in postoperative lung atelectasis using lung ultrasound following upper abdominal laparotomies: a prospective randomized study
    Hassan, Bahaa El-din Ewees
    El-Shaer, Ahmed Nagah
    Elbeialy, Marwa Ahmed Khairy
    Ismail, Shimaa Ahmed Mohamed
    AIN SHAMS JOURNAL OF ANESTHESIOLOGY, 2020, 12 (01)
  • [34] Comparison of effects of volume-controlled and pressure-controlled mode of ventilation on endotracheal cuff pressure and respiratory mechanics in laparoscopic cholecystectomies: A randomised controlled trial
    Nethra, S. S.
    Nagaraja, Swathi
    Sudheesh, K.
    Duggappa, Devika Rani
    Sanket, Bhargavi
    INDIAN JOURNAL OF ANAESTHESIA, 2020, 64 (10) : 842 - 848
  • [35] RANDOMIZED, PROSPECTIVE TRIAL OF PRESSURE-LIMITED VERSUS VOLUME-CONTROLLED VENTILATION IN SEVERE RESPIRATORY-FAILURE
    RAPPAPORT, SH
    SHPINER, R
    YOSHIHARA, G
    WRIGHT, J
    CHANG, P
    ABRAHAM, E
    CRITICAL CARE MEDICINE, 1994, 22 (01) : 22 - 32
  • [36] Effect of Pressure-Versus Volume-Controlled Ventilation on the Ventilatory and Hemodynamic Parameters During Laparoscopic Appendectomy in Children: A Prospective, Randomized Study
    Kim, Ji Young
    Shin, Cheung Soo
    Lee, Kyung Cheon
    Chang, Young Jin
    Kwak, Hyun Jeong
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2011, 21 (07): : 655 - 658
  • [37] Pressure versus volume-controlled ventilation with BASKA mask airway in laparoscopic cholecystectomy: A randomized clinical study
    Abdel-Wahab, Amani H.
    Torky, Radwan A.
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2023, 39 (01): : 460 - 467
  • [38] Nasal intermittent mandatory ventilation versus nasal continuous positive airway pressure for respiratory distress syndrome: A randomized, controlled, prospective study
    Kugelman, Amir
    Feferkorn, Ido
    Riskin, Arieh
    Chistyakov, Irena
    Kaufman, Bella
    Bader, David
    JOURNAL OF PEDIATRICS, 2007, 150 (05): : 521 - 526
  • [39] Comparative study of ventilation techniques with supraglottic airway devices in cats: volume-controlled vs pressure-controlled techniques
    Niyatiwatchanchai, Nutawan
    Rattanathanya, Hathaipat
    Thengchaisri, Naris
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2024, 26 (01)
  • [40] Benefit of Flow-Controlled Over Pressure-Regulated Volume Control Mode During One-Lung Ventilation: A Randomized Experimental Crossover Study
    Schranc, Almos
    Diaper, John
    Suedy, Roberta
    Fodor, Gergely H.
    Habre, Walid
    Albu, Gergely
    ANESTHESIA AND ANALGESIA, 2023, 136 (03): : 605 - 612