Three-Dimensional Finite Element Analysis of Prosthetic Finger Joint Implants

被引:0
|
作者
E.A. Biddis
E.R. Bogoch
S.A. Meguid
机构
[1] University of Toronto,Department of Mechanical and Industrial Engineering, Engineering Mechanics and Design Laboratory
[2] University of Toronto,Martin Family Centre for Arthritis Care and Research, Mobility Program, Department of Surgery, St. Michael‘s Hospital
关键词
finite element analysis; metacarpophalangeal joint; NeuFlex implant; Swanson implant; three-dimensional;
D O I
10.1007/s10999-005-3308-3
中图分类号
学科分类号
摘要
The purpose of this study was to develop high resolution three-dimensional (3D) finite element (FE) models of the Swanson® (No. 2) and NeuFlex® (No. 10) joint implants to: simulate implant function; evaluate stress distributions and bending stiffness of these implants; and assess their comparative potential for fracture and range of motion (ROM) in flexion and extension. Geometric representations of the implants accurate to within 20 μm were achieved using digital laser imaging technology. Images were transferred to ANSYS 5.7 using appropriate interfacing software and 3D FE models of the implants were constructed. Hyperelastic material properties of the silicone elastomers were derived experimentally from uniaxial tensile tests on implant sections. Both implants experienced maximum von Mises stresses at 90° of flexion and minimum stresses at the neutral position of flexion (Swanson: 0°, NeuFlex: 30°). Within the reported functional ROM (33°–73°), the NeuFlex implant exhibited lower maximum von Mises stress and bending stiffness than the Swanson. The Swanson implant, which has a straight hinge, exhibited lower peak stresses and bending stiffness than the NeuFlex for flexion less than 20°. Areas of high von Mises stress for the Swanson implant included the stem–hinge junction and the peripheral zone of the body of the hinge, corresponding to clinical reports of fractures. In the NeuFlex implant, the maximum stress occurred on the dorsal surface of the hinge. Bending stiffness of the NeuFlex implant was modelled to be substantially less than that of the Swanson throughout the functional ROM (33°–73° of flexion). The resting position of the Swanson implant is at 0° of flexion. A moment was required to extend the NeuFlex implant from 30° to 0° of flexion. These results suggest that the NeuFlex may potentially facilitate flexion of the metacarpophalangeal (MP) joint, whereas the Swanson may promote a more extended position of the joint.
引用
收藏
页码:317 / 328
页数:11
相关论文
共 50 条
  • [41] A three-dimensional finite element analysis of the sports mouthguard
    Gialain, Ivan Onone
    Coto, Neide Pena
    Driemeier, Larissa
    Noritomi, Pedro Yoshito
    Brito e Dias, Reinaldo
    DENTAL TRAUMATOLOGY, 2016, 32 (05) : 409 - 415
  • [42] Three-dimensional finite element analysis of tube spinning
    Hua, FA
    Yang, YS
    Zhang, YN
    Guo, MH
    Guo, DY
    Tong, WH
    Hu, ZQ
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2005, 168 (01) : 68 - 74
  • [43] Finite element procedures for three-dimensional pavement analysis
    Hjelmstad, KD
    Kim, J
    Zuo, QH
    AIRCRAFT/PAVEMENT TECHNOLOGY: IN THE MIDST OF CHANGE, 1997, : 125 - 137
  • [44] Three-dimensional finite element analysis of the Senise landslide
    Troncone, Antonello
    Conte, Enrico
    Donato, Antonio
    VI ITALIAN CONFERENCE OF RESEARCHERS IN GEOTECHNICAL ENGINEERING, CNRIG2016 - GEOTECHNICAL ENGINEERING IN MULTIDISCIPLINARY RESEARCH: FROM MICROSCALE TO REGIONAL SCALE, 2016, 158 : 212 - 217
  • [45] Three-dimensional finite element analysis of a strutted excavation
    Chew, SH
    Yong, KY
    Lim, AYK
    COMPUTER METHODS AND ADVANCES IN GEOMECHANICS, VOL 3, 1997, : 1915 - 1920
  • [46] Finite element simulations of stresses in bone implants made by three-dimensional printing
    Mikushev, V. M.
    Samarkin, A., I
    Khomutova, A. S.
    INTERNATIONAL CONFERENCE ON ADVANCED ENGINEERING AND TECHNOLOGY (ICAET 2020), 2021, 1117
  • [47] Finite element modeling of three-dimensional solder joint geometry in SMT
    Lee, TS
    Choi, TP
    Yoo, CD
    JOURNAL OF ELECTRONIC PACKAGING, 1997, 119 (02) : 119 - 126
  • [48] Comparative evaluation on three-dimensional finite element models of the temporomandibular joint
    Liu, Zhan
    Fan, Yubo
    Qian, Yingli
    CLINICAL BIOMECHANICS, 2008, 23 (SUPLL.1) : S53 - S58
  • [49] Construction and Validation of a Three-dimensional Finite Element Model of Hip Joint
    Wang, Monan
    Liang, Jianan
    2014 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS IEEE-ROBIO 2014, 2014, : 2609 - 2612
  • [50] Biomechanical three-dimensional finite element analysis of prostheses retained with/without zygoma implants in maxillectomy patients
    Wang, Mingyi
    Qu, Xingzhou
    Cao, Min
    Wang, Dongmei
    Zhang, Chenping
    JOURNAL OF BIOMECHANICS, 2013, 46 (06) : 1155 - 1161