Water target based cross-calibration of CBERS-02 CCD camera with MODIS data

被引:2
|
作者
Junwu Tang
Xingfa Gu
Shengli Niu
Chaofei Ma
Xiangjun Min
机构
[1] National Satellite Ocean Application Service (NSOAS),
[2] State Key Laboratory of Remote Sensing Science,undefined
[3] China Center for Resource Satellite Data and Applications (CRESDA),undefined
来源
关键词
CBERS-02 CCD; MODIS; radiometric calibration; cross-calibration;
D O I
10.1007/BF03039425
中图分类号
学科分类号
摘要
In order to make quantitative watercolor sensing with China-Brazil Earth Resources Satellite (CBERS-02) CCD camera, the MODIS data with higher accuracy is used to cross-calibrate the CCD camera over water targets. In homogeneous clear water area, two pairs of images obtained over the same area on the same day by the two sensors are selected. The top-of-atmosphere (TOA) radiances of the multispectral bands of CCD are calculated with the water and aerosol parameters from MODIS based on a water-atmosphere radiative transfer algorithm. The stripes in CCD image that caused by unequal response of the CCD array detectors are firstly removed before making the cross-calibration. The same part of CCD detectors is selected for the calibrations in the two images to eliminate the residual error of destriping and uniformity correction for the focus plane irradiance. It is shown that the calibration results from two different images are consistent. The error of this method is about 5%.
引用
收藏
页码:61 / 71
页数:10
相关论文
共 44 条
  • [31] Radiometric Cross-Calibration of GF-4/IRS Based on MODIS Measurements
    Zhou, Xiang
    Feng, Duo
    Xie, Yong
    Tao, Zui
    Lv, Tingting
    Wang, Jin
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2021, 14 : 6807 - 6814
  • [32] Cross-calibration of the Rosetta Navigation Camera based on images of the 67P comet nucleus
    Statella, Thiago
    Geiger, Bernhard
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2017, 469 : S285 - S294
  • [33] Cross-calibration of FY-2E/VISSR infrared window and water vapor channels with TERRA/MODIS
    Xu Na
    Hu Xiu-Qing
    Chen Lin
    Zhang Yu-Xiang
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2012, 31 (04) : 319 - +
  • [34] Distortion measurement and calibration technology for CCD camera system based on new target board
    School of Information Science and Technology, Beijing Institute of Technology, Beijing 100081, China
    Guangxue Xuebao, 2007, 8 (1440-1442):
  • [35] Spectral Cross-Calibration of VIIRS Enhanced Vegetation Index with MODIS: A Case Study Using Year-Long Global Data
    Obata, Kenta
    Miura, Tomoaki
    Yoshioka, Hiroki
    Huete, Alfredo R.
    Vargas, Marco
    REMOTE SENSING, 2016, 8 (01):
  • [36] Data Comparison and Cross-Calibration between Level 1 Products of DPC and POSP Onboard the Chinese GaoFen-5(02) Satellite
    Lei, Xuefeng
    Liu, Zhenhai
    Tao, Fei
    Dong, Hao
    Hou, Weizhen
    Xiang, Guangfeng
    Qie, Lili
    Meng, Binghuan
    Li, Congfei
    Chen, Feinan
    Xie, Yanqing
    Zhang, Miaomiao
    Fan, Lanlan
    Cheng, Liangxiao
    Hong, Jin
    REMOTE SENSING, 2023, 15 (07)
  • [37] Study on the cross-calibration of a charge-coupled device camera on the China-Brazil Earth Resources Satellite-02B by moderate resolution imaging spectroradiometer
    Zhang, Minwei
    Tang, Junwu
    Dong, Qing
    JOURNAL OF APPLIED REMOTE SENSING, 2010, 4
  • [38] Cross-calibration of S-NPP VIIRS moderate-resolution reflective solar bands against MODIS Aqua over dark water scenes
    Sayer, Andrew M.
    Hsu, N. Christina
    Bettenhausen, Corey
    Holz, Robert E.
    Lee, Jaehwa
    Quinn, Greg
    Veglio, Paolo
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2017, 10 (04) : 1425 - 1444
  • [39] Research for Extraction of Aquaculture Water Information in Coastal Zone Using CBERS-02B Data Based on Object-oriented Technique
    Xue Zhenshan
    Su Fenzhen
    Sun Xiaoyu
    Gao Yi
    2010 INTERNATIONAL CONFERENCE ON INNOVATIVE COMPUTING AND COMMUNICATION AND 2010 ASIA-PACIFIC CONFERENCE ON INFORMATION TECHNOLOGY AND OCEAN ENGINEERING: CICC-ITOE 2010, PROCEEDINGS, 2010, : 17 - 19
  • [40] Cross-ratio invariant based line scan camera geometric calibration with static linear data
    Li, Dongdong
    Wen, Gongjian
    Hui, Bing Wei
    Qiu, Shaohua
    Wang, Wenfei
    OPTICS AND LASERS IN ENGINEERING, 2014, 62 : 119 - 125