Rim-to-Disc Ratio Outperforms Cup-to-Disc Ratio for Glaucoma Prescreening

被引:0
|
作者
J. R. Harish Kumar
Chandra Sekhar Seelamantula
Yogish Subraya Kamath
Rajani Jampala
机构
[1] Indian Institute of Science,Department of Electrical Engineering
[2] Manipal Institute of Technology,Department of Electrical and Electronics Engineering
[3] Manipal Academy of Higher Education,Department of Ophthalmology
[4] Kasturba Medical College,undefined
[5] Manipal Academy of Higher Education,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
We present a novel and fully automated fundus image processing technique for glaucoma prescreening based on the rim-to-disc ratio (RDR). The technique accurately segments the optic disc and optic cup and then computes the RDR based on which it is possible to differentiate a normal fundus from a glaucomatous one. The technique performs a further categorization into normal, moderate, or severely glaucomatous classes following the disc-damage-likelihood scale (DDLS). To the best of our knowledge, this is the first engineering attempt at using RDR and DDLS to perform glaucoma severity assessment. The segmentation of the optic disc and cup is based on the active disc, whose parameters are optimized to maximize the local contrast. The optimization is performed efficiently by means of a multiscale representation, accelerated gradient-descent, and Green’s theorem. Validations are performed on several publicly available databases as well as data provided by manufacturers of some commercially available fundus imaging devices. The segmentation and classification performance is assessed against expert clinician annotations in terms of sensitivity, specificity, accuracy, Jaccard, and Dice similarity indices. The results show that RDR based automated glaucoma assessment is about 8% to 10% more accurate than a cup-to-disc ratio (CDR) based system. An ablation study carried out considering the ground-truth expert outlines alone for classification showed that RDR is superior to CDR by 5.28% in a two-stage classification and about 3.21% in a three-stage severity grading.
引用
收藏
相关论文
共 50 条
  • [21] Comparison of mean optic disc cup surface depth between glaucoma suspect and primary open-angle glaucoma with large cup-to-disc ratio
    Mun, Yongseok
    Ha, Ah Nul
    Jeoung, Jin Wook
    Park, Ki Ho
    Kim, Young Kook
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [22] COMPARISON BETWEEN FUNDUSCOPICALLY AND AUTOMATED MEASUREMENT OF CUP-TO-DISC RATIO
    WOLFS, RCW
    RAMRATTAN, RS
    DEJONG, PTVM
    VISION RESEARCH, 1995, 35 : 4136 - 4136
  • [23] Cup-to-Disc Ratio in Idiopathic Intracranial Hypertension without Papilloedema
    Hamill, Eric
    Kim, James D.
    Yalamanchili, Sushma
    Paranilam, Jaya M.
    Al Zubidi, Nagham
    Lee, Andrew G.
    NEURO-OPHTHALMOLOGY, 2014, 38 (02) : 69 - 73
  • [24] Direct Cup-to-Disc Ratio Estimation for Glaucoma Screening via Semi-Supervised Learning
    Zhao, Rongchang
    Chen, Xuanlin
    Liu, Xiyao
    Chen, Zailiang
    Guo, Fan
    Li, Shuo
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (04) : 1104 - 1113
  • [25] A Semiautomatic Superpixel Based Approach to Cup-to-Disc Ratio Measurement
    Santos, Elineide
    Santos, Luis
    Veras, Rodrigo
    Frazao, Marcos
    Leite, Daniel
    2018 IEEE SYMPOSIUM ON COMPUTERS AND COMMUNICATIONS (ISCC), 2018, : 626 - 631
  • [26] The impact of anthropometric and ocular parameters on optic cup-to-disc ratio
    Fukuoka, Hideki
    Tange, Chikako
    Otsuka, Rei
    Ando, Fujiko
    Shimokata, Hiroshi
    BMJ OPEN OPHTHALMOLOGY, 2016, 1 (01):
  • [27] Pupil Ruff Atrophy Correlations with Intraocular Pressure and Cup-to-Disc Ratio in a Glaucoma Clinic Population
    Ang, Ghee S.
    Wong, Tracey
    Nicholas, Simon
    Wells, Anthony P.
    OPHTHALMOLOGY, 2012, 119 (08) : 1546 - 1551
  • [28] ARGALI- an Automatic cup-to-disc Ratio measurement system for Glaucoma detection and AnaLysIs framework
    Liu, J.
    Wong, D. W. K.
    Lim, J. H.
    Li, H.
    Tan, N. M.
    Wong, T. Y.
    MEDICAL IMAGING 2009: COMPUTER-AIDED DIAGNOSIS, 2009, 7260
  • [29] Highly Accurate and Precise Automated Cup-to-Disc Ratio Quanti fi cation for Glaucoma Screening
    Chaurasia, Abadh K.
    Greatbatch, Connor J.
    Han, Xikun
    Gharahkhani, Puya
    Mackey, David A.
    MacGregor, Stuart
    Craig, Jamie E.
    Hewitt, Alex W.
    OPHTHALMOLOGY SCIENCE, 2024, 4 (05):
  • [30] Longitudinal quantitative evaluation of cup-to-disc ratio in treated primary open-angle glaucoma
    Kim, YI
    Pereira, MLM
    Zimmerman, MB
    Montague, PR
    Alward, WLM
    Kwon, YH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U219 - U219