sEMG-based impedance control for lower-limb rehabilitation robot

被引:0
|
作者
Vahab Khoshdel
Alireza Akbarzadeh
Nadia Naghavi
Ali Sharifnezhad
Mahdi Souzanchi-Kashani
机构
[1] Center of Excellence on Soft Computing and Intelligent Information Processing,Mechanical Engineering Department
[2] Ferdowsi University of Mashhad,Electrical Engineering Department, Faculty of Engineering
[3] Ferdowsi University of Mashhad,undefined
[4] Sport Science Research Institute of IRAN (SSRII),undefined
来源
关键词
Rehabilitation robot; Impedance control; Fuzzy adaptive; Voltage-based strategy; SEMG signals;
D O I
暂无
中图分类号
学科分类号
摘要
Recently, various rehabilitation robots have been developed for therapeutic exercises. Additionally, several control methods have been proposed to control the rehabilitation robots based on user’s motion intention. One of the common control methods used is torque-based impedance control. This paper presents an electromyogram-based robust impedance control for a lower-limb rehabilitation robot using a voltage-based strategy. The proposed control strategy uses surface electromyogram (sEMG) signals in place of force sensors to estimate the exerted force. In addition, the control is based on the voltage control strategy, which differs from the common torque control strategies. For example, unlike the torque-based impedance control, the controller is not dependent on the dynamical models of the patient and the robot. This is particularly important as the dynamic of the patient is both difficult to model precisely and changes during the rehabilitation period. These simplifications results in a significant reduction in calculation time. To illustrate the effectiveness of the control approach, a 1-DOF lower-limb rehabilitation robot is designed. Experimental sEMG-force data are collected and used to train an artificial neural network. Simulation results show that compared with a torque-based control approach, the voltage-based is simpler, less computational and more efficient while it considers the presence of actuators. Finally, we design an adaptive fuzzy system to estimate and compensate the uncertainty in performing the impedance rule. The adaptive fuzzy system has an advantage that does not need new feedback to estimate the uncertainty. The control approach is further verified by stability analysis. Simulation results show the efficiency of the control approach in performing some therapeutic exercises.
引用
收藏
页码:97 / 108
页数:11
相关论文
共 50 条
  • [41] EMG-Based Kinematic Impedance Control of a Lower-Limb Exoskeleton
    Luna, Lourdes
    Garcia, Itzel
    Mendoza, Marco
    Dorantes-Mendez, Guadalupe
    Mejia-Rodriguez, Aldo
    Bonilla, Isela
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 1494 - 1501
  • [42] Modeling the Kinematics and Dynamics of the Pedaling Lower-Limb Rehabilitation Robot
    Zhang, Hao
    Zhao, Juan
    Wang, Feng
    Kawata, Seiichi
    She, Jinhua
    2024 INTERNATIONAL WORKSHOP ON INTELLIGENT SYSTEMS, IWIS 2024, 2024,
  • [43] Dynamic Analysis and Control of a Hybrid Serial/Cable Driven Robot for Lower-Limb Rehabilitation
    Ismail, Mourad
    Lahouar, Samir
    Romdhane, Lotfi
    COMPUTATIONAL KINEMATICS, 2018, 50 : 109 - 116
  • [44] Design, kinematics, simulation, and experiment for a lower-limb rehabilitation robot
    Wang, H.
    Shi, X.
    Liu, H.
    Li, L.
    Hou, Z.
    Yu, H.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART I-JOURNAL OF SYSTEMS AND CONTROL ENGINEERING, 2011, 225 (I6) : 860 - 872
  • [45] Enhanced impedance control for an sEMG-based prosthetic using RNE approach
    Aiduonu, Papa Ekow
    Liu, Yang
    INTERNATIONAL JOURNAL OF ENGINEERING SYSTEMS MODELLING AND SIMULATION, 2021, 12 (2-3) : 94 - 102
  • [46] Research on Upper Limb Motion Intention Classification and Rehabilitation Robot Control Based on sEMG
    Song, Tao
    Zhang, Kunpeng
    Yan, Zhe
    Li, Yuwen
    Guo, Shuai
    Li, Xianhua
    SENSORS, 2025, 25 (04)
  • [47] Kinematics Modeling and Simulation of Trajectory Tracking Control of a Foot-Plate-Based Lower-Limb Rehabilitation Robot
    Xie S.
    Mei J.
    Liu H.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2018, 51 (05): : 443 - 452
  • [48] sEMG-Based Gesture Classifier for a Rehabilitation Glove
    Copaci, Dorin
    Arias, Janeth
    Gomez-Tome, Marcos
    Moreno, Luis
    Blanco, Dolores
    FRONTIERS IN NEUROROBOTICS, 2022, 16
  • [49] Control System of the Lower Limb Rehabilitation Robot
    Michnik, Andrzej
    Brandt, Jacek
    Szczurek, Zbigniew
    Bachorz, Michal
    Paszenda, Zbigniew
    Michnik, Robert
    Jurkojc, Jacek
    INFORMATION TECHNOLOGIES IN BIOMEDICINE, ITIB 2012, 2012, 7339 : 478 - 488
  • [50] Control strategies for lower limb rehabilitation robot
    Chen, Jiangcheng
    Zhang, Xiaodong
    Wang, He
    Shi, Qiangyong
    Li, Rui
    2014 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION (ICIA), 2014, : 121 - 125