Computed tomography imaging with the Adaptive Statistical Iterative Reconstruction (ASIR) algorithm: dependence of image quality on the blending level of reconstruction

被引:0
|
作者
Patrizio Barca
Marco Giannelli
Maria Evelina Fantacci
Davide Caramella
机构
[1] University of Pisa,Department of Physics
[2] INFN,Unit of Medical Physics
[3] Pisa section,Diagnostic and Interventional Radiology
[4] Pisa University Hospital “Azienda Ospedaliero-Universitaria Pisana”,undefined
[5] University of Pisa,undefined
来源
Australasian Physical & Engineering Sciences in Medicine | 2018年 / 41卷
关键词
Computed tomography; Adaptive Statistical Iterative Reconstruction; Image quality; Noise; Modulation transfer function;
D O I
暂无
中图分类号
学科分类号
摘要
Computed tomography (CT) is a useful and widely employed imaging technique, which represents the largest source of population exposure to ionizing radiation in industrialized countries. Adaptive Statistical Iterative Reconstruction (ASIR) is an iterative reconstruction algorithm with the potential to allow reduction of radiation exposure while preserving diagnostic information. The aim of this phantom study was to assess the performance of ASIR, in terms of a number of image quality indices, when different reconstruction blending levels are employed. CT images of the Catphan-504 phantom were reconstructed using conventional filtered back-projection (FBP) and ASIR with reconstruction blending levels of 20, 40, 60, 80, and 100%. Noise, noise power spectrum (NPS), contrast-to-noise ratio (CNR) and modulation transfer function (MTF) were estimated for different scanning parameters and contrast objects. Noise decreased and CNR increased non-linearly up to 50 and 100%, respectively, with increasing blending level of reconstruction. Also, ASIR has proven to modify the NPS curve shape. The MTF of ASIR reconstructed images depended on tube load/contrast and decreased with increasing blending level of reconstruction. In particular, for low radiation exposure and low contrast acquisitions, ASIR showed lower performance than FBP, in terms of spatial resolution for all blending levels of reconstruction. CT image quality varies substantially with the blending level of reconstruction. ASIR has the potential to reduce noise whilst maintaining diagnostic information in low radiation exposure CT imaging. Given the opposite variation of CNR and spatial resolution with the blending level of reconstruction, it is recommended to use an optimal value of this parameter for each specific clinical application.
引用
收藏
页码:463 / 473
页数:10
相关论文
共 50 条
  • [21] Image quality in coronary computed tomography angiography: influence of adaptive statistical iterative reconstruction at various radiation dose levels
    Precht, Helle
    Gerke, Oke
    Thygesen, Jesper
    Egstrup, Kenneth
    Auscher, Soren
    Waaler, Dag
    Lambrechtsen, Jess
    ACTA RADIOLOGICA, 2018, 59 (10) : 1194 - 1202
  • [22] A qualitative and quantitative analysis of radiation dose and image quality of computed tomography images using adaptive statistical iterative reconstruction
    Hussain, Fahad Ahmed
    Mail, Noor
    Shamy, Abdulrahman M.
    Alghamdi, Suliman
    Saoudi, Abdelhamid
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 419 - 432
  • [23] Dual-Energy Spectral Computed Tomography With Adaptive Statistical Iterative Reconstruction for Improving Image Quality of Portal Venography
    Wang, Weibing
    Huang, Jinbai
    Wang, Ai
    Li, Yun
    Peng, Jie
    Hu, Xinjie
    Liu, Yingjun
    Zhang, Haiyan
    Li, Xiaohu
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 954 - 958
  • [24] Impact of deep learning-based image reconstruction on image quality compared with adaptive statistical iterative reconstruction-Veo in renal and adrenal computed tomography
    Bie, Yifan
    Yang, Shuo
    Li, Xingchao
    Zhao, Kun
    Zhang, Changlei
    Zhong, Hai
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (03) : 409 - 418
  • [25] ASSESSMENT OF CLINICAL IMAGE QUALITY IN PAEDIATRIC ABDOMINAL CT EXAMINATIONS: DEPENDENCY ON THE LEVEL OF ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION (ASIR) AND THE TYPE OF CONVOLUTION KERNEL
    Larsson, Joel
    Bath, Magnus
    Ledenius, Kerstin
    Caisander, Hakan
    Thilander-Klang, Anne
    RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 123 - 129
  • [26] Improved iterative image reconstruction algorithm for the exterior problem of computed tomography
    Guo, Yumeng
    Zeng, Li
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 842 : 96 - 108
  • [27] Deep learning–based image reconstruction for brain CT: improved image quality compared with adaptive statistical iterative reconstruction-Veo (ASIR-V)
    Injoong Kim
    Hyunkoo Kang
    Hyun Jung Yoon
    Bo Mi Chung
    Na-Young Shin
    Neuroradiology, 2021, 63 : 905 - 912
  • [28] An ART iterative reconstruction algorithm for computed tomography of diffraction enhanced imaging
    王振天
    张丽
    黄志峰
    康克军
    陈志强
    方侨光
    朱佩平
    中国物理C, 2009, (11) : 975 - 980
  • [29] An ART iterative reconstruction algorithm for computed tomography of diffraction enhanced imaging
    Wang Zhen-Tian
    Zhang Li
    Huang Zhi-Feng
    Kang Ke-Jun
    Chen Zhi-Qiang
    Fang Qiao-Guang
    Zhu Pei-Ping
    CHINESE PHYSICS C, 2009, 33 (11) : 975 - 980
  • [30] Chest Computed Tomography Images in Neonatal Bronchial Pneumonia under the Adaptive Statistical Iterative Reconstruction Algorithm
    Sun, Ying
    Wu, Liao
    Tian, Zhaofang
    Bao, Tianping
    JOURNAL OF HEALTHCARE ENGINEERING, 2021, 2021