Monte-Carlo Calculation of the γ-Ray Dose Distribution Inside a Wall of a Building and in Air

被引:0
|
作者
M. Yu. Orlov
V. F. Stepanenko
T. V. Kolyzhenkov
M. Hoshi
J. Takada
机构
[1] Medical Radiological Scientific Center of the Russian Academy of Medical Sciences,Scientific
[2] Hiroshima University,Research Institute of Nuclear Medecine and Biology
来源
Atomic Energy | 2003年 / 94卷
关键词
Monte Carlo Method; Soil Surface; Dose Distribution; Average Energy; Luminescence Dosimetry;
D O I
暂无
中图分类号
学科分类号
摘要
The Monte Carlo method is used to calculate the coefficients used to convert from the measured (using retrospective luminescence dosimetry) γ-ray dose inside the wall of a building to the dose in air. The γ-ray dose distributions in the wall and in air were calculated simultaneously. The calculations were performed for a γ-ray sources located in air, on the surface of soil, and in a 0–5 cm thick top layer of soil. The γ-ray spectra in air and inside a wall are calculated and it is shown that the spectrum depends strongly on the type of source – the average energy of the spectrum is 0.25 MeV for a source located on a soil surface, 0.39 MeV for a source located inside the soil, and 0.53 MeV for a source located in air.
引用
收藏
页码:428 / 433
页数:5
相关论文
共 50 条
  • [22] Monte-Carlo calculation of the secondary electron spectra inside and around gold nanoparticles
    Gargioni, E.
    Dressel, T.
    Rabus, H.
    Bug, M. U.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S926 - S926
  • [23] Validation of Monte-Carlo Proton Dose Calculation for Real Tissue Samples
    Wang, H.
    Wu, J.
    Zhang, R.
    Baer, E.
    Geng, C.
    Jee, K.
    Sharp, G.
    Paganetti, H.
    Tang, J.
    Lu, H.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [24] MONTE-CARLO CALCULATION OF GAMMA-DOSE FROM INTERNAL SOURCE
    GUINSBURG, GK
    WATANABE, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 119 - 119
  • [25] A MONTE-CARLO CALCULATION OF THE EXPOSURE DOSE DUE TO THE RADIOACTIVE LIGHTNING ROD
    NIKEZIC, DR
    MARKOVIC, PD
    ACTA PHYSICA HUNGARICA, 1986, 59 (1-2) : 91 - 93
  • [26] MONTE-CARLO CALCULATION AND SILICON DETECTOR MEASUREMENT OF THE HOT PARTICLE DOSE
    CHUNG, M
    LEVINE, SH
    JESTER, WA
    HEALTH PHYSICS, 1991, 61 (06): : 843 - 848
  • [27] CALCULATION OF ABSORBED DOSE RATIOS USING CORRELATED MONTE-CARLO SAMPLING
    MA, CM
    NAHUM, AE
    MEDICAL PHYSICS, 1993, 20 (04) : 1189 - 1199
  • [28] Independent Monte-Carlo dose calculation for MLC based CyberKnife radiotherapy
    Mackeprang, P-H
    Vuong, D.
    Volken, W.
    Henzen, D.
    Schmidhalter, D.
    Malthaner, M.
    Mueller, S.
    Frei, D.
    Stampanoni, M. F. M.
    Dal Pra, A.
    Aebersold, D. M.
    Fix, M. K.
    Manser, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (01):
  • [29] Monte-Carlo calculation of integral dose for gamma knife treatment planning
    Li, K.
    Wang, J.
    Cai, M.
    Mayr, N.
    MEDICAL PHYSICS, 2007, 34 (06) : 2473 - 2473
  • [30] CALCULATION OF X-RAY GRID CHARACTERISTICS BY MONTE-CARLO METHODS
    KALENDER, WA
    PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (03): : 353 - 361