Effects of repeated high-temperature cycles on the thermal contact resistance of bimetallic finned tubes

被引:1
|
作者
Piir A.É. [1 ]
Roshchin S.P. [1 ]
Vereshchagin A.Yu. [1 ]
Kuntysh V.B. [2 ]
Minnigaleev A.Sh. [3 ]
机构
[1] Arkhangel’sk State Technical University,
[2] Belarus State Technological University,undefined
[3] Oktyabr’skkhimmash ZAO,undefined
关键词
Calorimeter; Contact Zone; Thermal Contact Resistance; Rolled Finning; Tube Wall Temperature;
D O I
10.1007/s10556-007-0091-z
中图分类号
学科分类号
摘要
Measurements have been made on the thermal contact resistance (TCR) in repeated cycles of heating to 270°C and cooling to 50°C in experimental specimens of bimetallic finned tubes having roll and strip fins. Tenfold heating-cooling cycles increase the TCR of these tubes in the cold state by factors of 1.5-2.5. © 2007 Springer Science+Business Media, Inc.