摘要
A sensitive, simple, and reproducible method was developed in this study for the determination of pramipexole, and in doing that, a glassy carbon electrode modified with –COOH-functionalized multi-walled carbon nanotube was utilized. The modified electrode was compared with a bare glassy carbon electrode in order to prove the sensitivity of the developed sensor. Cyclic, differential pulse, and adsorptive stripping differential pulse voltammetric techniques were used to investigate the oxidation behavior and stripping techniques were used for the determination of pramipexole. Based on optimum experimental conditions, calibration and partial validation studies were realized for bare and modified electrodes. As a result, the values of limit of detection and quantification were determined as be 2.38 × 10−10 and 7.93 × 10−10 M for bare and 1.06 × 10−10 and 3.52 × 10−10 M for modified glassy carbon electrodes, respectively. The applicability of the bare and modified electrodes was demonstrated for the determination of pramipexole in pharmaceutical dosage forms. The selectivity of the developed method was considered in the presence of Ca2+, Na+, K+, and glucose, ascorbic acid, uric acid, and dopamine. Interfering agents except uric acid did not affect pramipexole determination considerably.
引用
收藏
页码:2519 / 2528
页数:9
相关论文
共 50 条
  • [21] Electrochemical Determination of Rifampicin Based on Its Oxidation Using Multi-Walled Carbon Nanotube-Modified Glassy Carbon Electrodes
    Kul, Dilek
    TURKISH JOURNAL OF PHARMACEUTICAL SCIENCES, 2020, 17 (04) : 398 - 407
  • [22] Detection of Trace Heavy Metal Ions Using Carbon Nanotube-Modified Electrodes
    Morton, Jeffrey
    Havens, Nathaniel
    Mugweru, Amos
    Wanekaya, Adam K.
    ELECTROANALYSIS, 2009, 21 (14) : 1597 - 1603
  • [23] VOLTAMMETRIC DETERMINATION OF TRACE MERCURY IN CHLORIDE MEDIA AT GLASSY-CARBON ELECTRODES MODIFIED WITH POLYCATIONIC IONOMERS
    UGO, P
    MORETTO, LM
    MAZZOCCHIN, GA
    ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 74 - 82
  • [24] Electrochemical behavior of L-dopa at single-wall carbon nanotube-modified glassy carbon electrodes
    Yan, XX
    Pang, DW
    Lu, ZX
    Lü, HQ
    Tong, H
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 569 (01) : 47 - 52
  • [25] Electrocatalytic detection of insulin at RuOx/carbon nanotube-modified carbon electrodes
    Wang, Joseph
    Tangkuaram, Tanin
    Loyprasert, Suchera
    Vazquez-Alvarez, Terannie
    Veerasai, Waret
    Kanatharana, Proespichaya
    Thavarungkul, Panote
    ANALYTICA CHIMICA ACTA, 2007, 581 (01) : 1 - 6
  • [26] Voltammetric determination of 4-chlorophenol using multiwall carbon nanotube/gold nanoparticle nanocomposite modified glassy carbon electrodes
    Wang, Ling
    Sun, Qi
    Liu, Yang
    Lu, Zhisong
    RSC ADVANCES, 2016, 6 (41) : 34692 - 34698
  • [27] Electrochemical determination of bisphenol A using a polyacrylamide-multiwalled carbon nanotube-modified glassy carbon electrode
    Han, Jian
    Li, Faying
    Jiang, Liping
    Li, Kai
    Dong, Yunhui
    Li, Yueyun
    ANALYTICAL METHODS, 2015, 7 (19) : 8220 - 8226
  • [28] Metal nanoparticles/carbon nanotube modified electrodes for voltammetric determination of boron
    Liv, Lokman
    Dursun, Zekerya
    Nakiboglu, Nuri
    TURKISH JOURNAL OF CHEMISTRY, 2018, 42 (06) : 1611 - 1622
  • [29] Carbon nanotube-modified electrodes for solar energy conversion
    Umeyama, Tomokazu
    Imahori, Hiroshi
    ENERGY & ENVIRONMENTAL SCIENCE, 2008, 1 (01) : 120 - 133
  • [30] Voltammetric determination of copper in water samples using a Schiff base/carbon nanotube-modified carbon paste electrode
    Izadkhah, V.
    Farmany, A.
    Mortazavi, S. S.
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2015, 21 : 994 - 996