A Hydraulic Performance Comparison of Centrifugal Pump Operating in Pump and Turbine Modes

被引:0
|
作者
Cui Dai
Liang Dong
Haibo Lin
Fei Zhao
机构
[1] Jiangsu University,School of Energy and Power Engineering
[2] Sichuan University of Science & Engineering,Sichuan Provincial Key Lab of Process Equipment and Control
[3] Jiangsu University,Research Center of Fluid Machinery Engineering and Technology
[4] Wuxi Institute of Technology,School of Mechanical Research Center of Technology
来源
关键词
Computational Fluid Dynamics; centrifugal pump; impeller modification; pump mode; turbine mode;
D O I
暂无
中图分类号
学科分类号
摘要
The modifications of impeller may show diverse impact on centrifugal pump operating in pump and turbine modes. To clarify this problem, the hydraulic performance of a low specific speed centrifugal pump operating in both modes was firstly obtained by CFD method and verified by experiment. Then, based on the single-factor design method, a series of calculations have been conducted to identify the effects of impeller geometry parameters on the hydraulic performance in different modes. The variations of head, shaft power and hydraulic efficiency curves with different impeller parameters were explored. It is found that compared with turbine, the pump shows a more obvious variation of head. The outlet angle has positive impact both on the head consumed by pump or generated by turbine. The change of turbine shaft power is apparently smaller than that of pump for different impeller geometry parameters. Only the outlet width somewhat changes the turbine shaft power. The hydraulic efficiency in both modes shows different variation under different impeller geometric parameters, while the hydraulic efficiency of both modes is reduced with the outlet angle increasing. Meanwhile, the response amount of hydraulic efficiency caused by certain change of impeller parameters was estimated by sensitivity analysis method. It is found that only the appropriate blade number and outlet width can improve the hydraulic performance both in pump and turbine modes. Eventually, the hydraulic loss, skin friction loss and theoretical analysis were performed to explore the reason of hydraulic performance variation due to different impeller parameters. The change of slip factor, impeller inlet area, impeller outlet area or hydraulic loss results in the change of hydraulic performance in both modes. The results can be useful for hydraulic performance improvement for both pump and turbine modes through impeller geometry modification.
引用
收藏
页码:1594 / 1605
页数:11
相关论文
共 50 条
  • [11] End Suction Centrifugal Pump Operating in Turbine Mode for Microhydro Applications
    Ismail, Mohd Azlan
    Othman, Al Khalid
    Islam, Shahidul
    Zen, Hushairi
    ADVANCES IN MECHANICAL ENGINEERING, 2014,
  • [12] COMPARATIVE STUDY ON HYDRAULIC PERFORMANCE OF SINGLE-SUCTION CENTRIFUGAL PUMP AND DOUBLE-SUCTION CENTRIFUGAL PUMP
    Wang, Chaoyue
    Wang, Fujun
    Zou, Zhichao
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2017, VOL 1A, 2017,
  • [13] Optimized Blade Design of Counter-Rotating-Type Pump-Turbine Unit Operating in Pump and Turbine Modes
    Kim, Jin-Woo
    Suh, Jun-Won
    Choi, Young-Seok
    Lee, Kyoung-Yong
    Kanemoto, Toshiaki
    Kim, Jin-Hyuk
    INTERNATIONAL JOURNAL OF ROTATING MACHINERY, 2018, 2018
  • [14] Hydraulic Design Optimization and Performance Analysis of a Centrifugal Blood Pump
    Park, Moo Ryong
    Yoo, Seong Yeon
    Oh, Hyoung Woo
    Yoon, Eui Soo
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2006, 30 (01) : 87 - 94
  • [15] Investigation of the hydraulic design for a high-performance centrifugal pump
    Nagahara, T.
    Okihara, T.
    Torii, D.
    26TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, PTS 1-7, 2013, 15
  • [16] Numerical study of operating performance of a centrifugal pump as turbine at overload with special emphasis on unsteady blade load
    Wei, Yangyang
    Shi, Weidong
    Zhou, Ling
    Li, Wei
    Zhang, Weibin
    Jiang, Wei
    MODERN PHYSICS LETTERS B, 2021, 35 (02):
  • [17] Calculation method of slip factor for impeller outlet of centrifugal pump as hydraulic turbine
    Shi, Guangtai
    Yang, Junhu
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2014, 30 (13): : 68 - 77
  • [18] Design, Fabrication and Testing of a Hydraulic Turbine Runner for a Double Suction Centrifugal Pump in Turbine Mode
    Villanueva, Mark D.
    Hapitan, Joffrey E.
    2019 8TH INTERNATIONAL CONFERENCE ON INFORMATICS, ENVIRONMENT, ENERGY AND APPLICATIONS (IAEA 2019), 2019, : 94 - 98
  • [19] Noise comparison of centrifugal pump operating in pump and turbine mode离心泵与透平运行工况的噪声对比
    Liang Dong
    Cui Dai
    Hai-bo Lin
    Yi-ping Chen
    Journal of Central South University, 2018, 25 : 2733 - 2753
  • [20] HYDRAULIC DRAG AT A CENTRIFUGAL PUMP IMPELLER
    SHAPIRO, AS
    NEKLYUDO.LV
    RUSSIAN ENGINEERING JOURNAL-USSR, 1968, 48 (05): : 25 - &