Evaluation of ultrasound lung comets by hand-held echocardiography

被引:165
|
作者
Bedetti G. [1 ]
Gargani L. [2 ]
Corbisiero A. [3 ]
Frassi F. [2 ]
Poggianti E. [2 ]
Mottola G. [3 ]
机构
[1] Imola Hospital, Imola
[2] CNR, Institute of Clinical Physiology, Pisa
[3] Montevergine Clinic, Mercogliano
关键词
Extravascular Lung Water; Short Learning Curve; Interlobular Septum; Chest Ultrasound; Bedside Evaluation;
D O I
10.1186/1476-7120-4-34
中图分类号
学科分类号
摘要
Background: Ultrasound lung comets (ULCs) are a clinically useful sign of extravascular lung water. They require very limited technology (2 D-echo), and a short learning curve. The aim of the present study is to compare ULCs information obtained by experienced echocardiologists using a full feature echocardiographic platform and by inexperienced sonographers using a hand-held echocardiography system. Methods: 20 consecutive in-hospital patients underwent, within 15′ and in random order, 2 ultrasound examinations for ULCs by 2 observers with different specific expertise and different technology: 1) "high-tech veteran": ULCs assessment with full feature echocardiographic platform (HP Sonos 7500 Philips Medical Systems, Andover, MA, USA) by a trained echocardiologist, with ≥2 years expertise in ULCs assessment and accredited by the European Association of Echocardiography; 2) and a "low-tech beginner": ULCs assessment with hand-held echocardiography (Optigo; Philips, Andover, MA) by an echocardiographer with very limited (30') dedicated training on ULCs assessment. In each patient, ULC score was obtained by summing the number of comets from each of the scanning spaces in the anterior right and left hemithorax, from the second to the fifth intercostal space. Results: There was a significant, tight correlation (r = .958, p < 0.001) between the 2 observations in the same patient by "high-tech veteran" and "low-tech beginner". Conclusion: ULCs are equally reliable in the hands of highly experienced echocardiologists using full feature echocardiographic platforms and in the hands of absolute beginners with miniaturized, compact, and battery-equipped echocardiographic systems. From the technological and expertise viewpoint, ULCs are the "kindergarten" of echocardiography, ideally suited for bedside evaluation of patients with both known or suspected heart failure. © 2006 Bedetti et al; licensee BioMed Central Ltd.
引用
收藏
相关论文
共 50 条
  • [41] Hand-Held Device
    Hadas, Rachel
    HUDSON REVIEW, 2019, 71 (04): : 791 - 794
  • [42] HAND-HELD HOLOGRAPHY
    STROKE, GW
    FUNKHOUSER, A
    LEONARD, C
    INDEBETOUW, G
    ZECH, RG
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1967, 57 (01) : 110 - +
  • [43] HAND-HELD INSTRUMENTS
    DICKENS, RE
    CONTROL AND INSTRUMENTATION, 1977, 9 (09): : 22 - 23
  • [44] Hand-held executions
    Parmenter, C
    AMERICAN BOOK REVIEW, 2005, 26 (04) : 29 - 29
  • [45] HAND-HELD MYOMETRY
    BOHANNON, RW
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1992, 55 (10): : 982 - 982
  • [46] A HAND-HELD KERATOMETER
    LAM, AKC
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1995, 15 (03) : 227 - 230
  • [47] Diagnostic ability of hand-held echocardiography in ventilated critically ill patients
    Vignon, P
    Chastagner, C
    François, B
    Martaillé, JF
    Normand, S
    Bonnivard, M
    Gastinne, H
    CRITICAL CARE, 2003, 7 (05): : R84 - R91
  • [49] The rate at which residents learn to use hand-held echocardiography at the bedside
    Hellmann, DB
    Whiting-O'Keefe, Q
    Shapiro, EP
    Martin, LD
    Martire, C
    Ziegelstein, RC
    AMERICAN JOURNAL OF MEDICINE, 2005, 118 (09): : 1010 - 1018
  • [50] Accuracy of hand-held ultrasound scanning in detecting meniscal tears
    Shetty, A. A.
    Tindall, A. J.
    James, K. D.
    Relwani, J.
    Fernando, K. W.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (08): : 1045 - 1048