Evaluation of right ventricular volume and mass using retrospective ECG-gated cardiac multidetector computed tomography: comparison with first-pass radionuclide angiography

被引:0
|
作者
Tae Hoon Kim
Young Hoon Ryu
Jin Hur
Sang Jin Kim
Hyun Soo Kim
Byoung Wook Choi
Young Kim
Hyung Jung Kim
机构
[1] Yonsei University College of Medicine,Department of Radiology
[2] Yonsei University College of Medicine,Department of Pulmonology
[3] Yongdong Severance Hospital,Department of Radiology
来源
European Radiology | 2005年 / 15卷
关键词
Right ventricular function; Computed tomography; Radionuclide angiography;
D O I
暂无
中图分类号
学科分类号
摘要
The purposes of this study were to evaluate the right ventricular (RV) volume and mass using cardiac multidetector computed tomography (MDCT) and to compare the cardiac MDCT results with those from first-pass radionuclide angiography (FPRA). Twenty patients were evaluated for the RV end-diastolic volume (RVEDV), the RV end-systolic volume (RVESV), the RV ejection fraction (RVEF), and RV mass using cardiac MDCT with a two-phase reconstruction method based on ECG. The end-diastolic phase was reconstructed at the starting point of the QRS complex on ECG, and the end-systolic phase was reconstructed at the halfway point of the ascending T-wave on ECG. The RV mass was measured for the end-systole. The RVEF was also obtained by FPRA. The mean RVEF (47±7%) measured by cardiac MDCT was well correlated with that (44±6%) measured by FPRA (r=0.854). A significant difference in the mean RVEF was found between cardiac MDCT and FPRA (p=0.001), with an overestimation of 2.9±5.3% by cardiac MDCT versus FPRA. The interobserver variability was 4.4% for the RVEDV, 6.8% for the RVESV, and 7.9% for the RV mass, respectively. Cardiac MDCT is relatively simple and allows the RV volume and mass to be assessed, and the RVEF obtained by cardiac MDCT correlates well with that measured by FPRA.
引用
收藏
页码:1987 / 1993
页数:6
相关论文
共 50 条
  • [41] Evaluation of global left ventricular myocardial function using retrospectively ECG-gated 16-slice multi-slice spiral computed tomography: Comparison with magnetic resonance imaging and echocardiography
    Burgstahler, C
    Heuschmid, M
    Beck, T
    Kuettner, A
    Kopp, AF
    Schroeder, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 284A - 284A
  • [42] RIGHT VENTRICULAR FUNCTION EVALUATION BY GATED BLOOD-POOL SINGLE PHOTON ELECTRON COMPUTED TOMOGRAPHY: A COMPARISON WITH CARDIAC MAGNETIC RESONANCE AND ECHOCARDIOGRAPHY
    Anderson, K.
    Ducharme, A.
    Finnerty, V.
    Gregoire, J.
    Marcotte, F.
    Harel, F.
    CANADIAN JOURNAL OF CARDIOLOGY, 2012, 28 (05) : S369 - S369
  • [43] Global and regional evaluation of systolic and diastolic left ventricular temporal parameters using a novel program for ECG-gated myocardial perfusion SPECT - Validation by comparison with gated equilibrium radionuclide angiography and speckle-tracking radial strain from echocardiography
    Yamamoto, Akira
    Takahashi, Naoto
    Munakata, Kazuo
    Hosoya, Tetsuo
    Shiiba, Masato
    Okuyama, Takao
    Abe, Kazuya
    Kaneshiro, Tadashi
    Tsuruta, Haruko
    Takama, Toshi
    Sato, Masashi
    ANNALS OF NUCLEAR MEDICINE, 2007, 21 (02) : 115 - 121
  • [44] Global and regional evaluation of systolic and distolic left ventricular temporal parameters using a novel program for ECG-gated myocardial perfusion SPECT—Validation by comparison with gated equilibrium radionuclide angiography and speckle-tracking radial strain from echocardiography—
    Akira Yamamoto
    Naoto Takahashi
    Kazuo Munakata
    Tetsuo Hosoya
    Masato Shiiba
    Takao Okuyama
    Kazuya Abe
    Tadashi Kaneshiro
    Haruko Tsuruta
    Toshi Takama
    Masashi Sato
    Annals of Nuclear Medicine, 2007, 21 : 115 - 121
  • [45] Retrospective ECG-gated left ventriculography using multislice CT following left ventricular bolus injection and evaluation of its utility and motion artifact at every cardiac phase
    Funabashi, Nobusada
    Komiyama, Nobuyuki
    Kato, Hideyuki
    Umekita, Hideo
    Asano, Miki
    Komuro, Issel
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 113 (01) : 132 - 138
  • [46] Evaluation of the hepatic artery in potential donors for living donor liver transplantation by computed tomography angiography using multidetector-row computed tomography: Comparison of volume rendering and maximum intensity projection techniques
    Byun, JH
    Kim, TK
    Lee, SS
    Lee, JK
    Ha, HK
    Kim, AY
    Kim, PN
    Lee, MG
    Lee, SG
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (02) : 125 - 131
  • [47] Evaluation of right ventricular function by coronary computed tomography angiography using a novel automated 3D right ventricle volume segmentation approach: a validation study
    Burghard, Philipp
    Plank, Fabian
    Beyer, Christoph
    Mueller, Silvana
    Doerler, Jakob
    Zaruba, Marc-Michael
    Poelzl, Leo
    Poelzl, Gerhard
    Klauser, Andrea
    Rauch, Stefan
    Barbieri, Fabian
    Langer, Christian-Ekkehardt
    Schgoer, Wilfried
    Williamson, Eric E.
    Feuchtner, Gudrun
    EUROPEAN RADIOLOGY, 2018, 28 (12) : 5129 - 5136
  • [48] Evaluation of right ventricular function by coronary computed tomography angiography using a novel automated 3D right ventricle volume segmentation approach: a validation study
    Philipp Burghard
    Fabian Plank
    Christoph Beyer
    Silvana Müller
    Jakob Dörler
    Marc-Michael Zaruba
    Leo Pölzl
    Gerhard Pölzl
    Andrea Klauser
    Stefan Rauch
    Fabian Barbieri
    Christian-Ekkehardt Langer
    Wilfried Schgoer
    Eric E. Williamson
    Gudrun Feuchtner
    European Radiology, 2018, 28 : 5129 - 5136
  • [49] Comparison of measurement of left ventricular ejection fraction by Tc-99m sestamibi first-pass angiography with electron beam computed tomography in patients with anterior wall acute myocardial infarction
    Gerber, TC
    Behrenbeck, T
    Allison, T
    Mullan, BP
    Rumberger, JA
    Gibbons, RJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (07): : 1022 - 1026
  • [50] Reliability of measurement of left ventricular ejection fraction by gated SPECT Tc-99m sestamibi imaging and Ta-178 first-pass radionuclide angiography with the conventional method using multicrystal camera
    Cohen, Y
    Mishra, JP
    Cassell, D
    Acio, ER
    Heo, J
    Iskandrian, AE
    CIRCULATION, 1997, 96 (08) : 2108 - 2108