Use of the optical access trocar for safe and rapid entry in various laparoscopic procedures

被引:0
|
作者
A. String
E. Berber
A. Foroutani
J.R. Macho
J.M. Pearl
A.E. Siperstein
机构
[1] Department of General Surgery,
[2] The Cleveland Clinic Foundation,undefined
[3] 9500 Euclid Avenue,undefined
[4] Cleveland,undefined
[5] OH 44195,undefined
[6] USA,undefined
[7] Department of Surgery,undefined
[8] University of California San Francisco,undefined
[9] 1600 Divisadero St.,undefined
[10] Mount Zion Medical Center,undefined
[11] San Francisco,undefined
[12] CA,undefined
[13] 94115,undefined
[14] USA,undefined
来源
Surgical Endoscopy | 2001年 / 15卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Background: The use of the Veress needle in laparoscopy to create the pneumoperitoneum has inherent risks; it may cause vascular and visceral injuries. The open technique is compromised by the leakage of carbon dioxide and can also be time consuming. One alternative is to enter the abdomen using an optical trocar under direct view. Our aim was to determine whether the optical access trocar can be used to effect a safe and rapid entry in various laparoscopic procedures. Methods: Over a 4-year period, the Optiview trocar was used for initial entry in 650 laparoscopic procedures. The procedures included cholecystectomy (n = 282), transabdominal inguinal hernia repair (n = 76), radiofrequency ablation of liver tumors (n = 73), adrenalectomy (n = 54), appendectomy (n = 41), colorectal surgery (n = 39), and various other procedures (n = 85). The following parameters were analyzed: presence of previous abdominal operations, site and duration of entry, and complications. Results: Of the 650 patients, 156 (24%) had had previous abdominal operations. In 25 cases, previous trocar sites were reused for optical access. The optical trocar was inserted at the umbilicus in 495 patients (76%), in the right upper quadrant in 77 (12%), in the left upper quadrant in 26 (4%), in the upper midline in eight (1%), in the right lower quadrant in six (0.9%), and in the left lower quadrant in three (0.5%). In 35 patients undergoing posterior adrenalectomy, optical trocars were used to enter Gerota's space. Mean (SD) entry times were 92 (45) sec at the umbilical site, 114 (30) sec at the back, and 77 (35) sec at the remaining sites. Complications (0.3%) included one injury to the bowel and one injury to the gallbladder; however, they were recognized and repaired immediately. Conclusions: To our knowledge, this report comprises the largest series in which the optical access trocar was used for laparoscopic surgery. This device provides the basis for a safe and fast technique for initial trocar placement: it also has the potential to reduce costs. Thanks to our favorable experience, the optical trocar method has become the standard technique for abdominal access in our laparoscopic practice since 1995.
引用
收藏
页码:570 / 573
页数:3
相关论文
共 50 条
  • [1] Use of the optical access trocar for safe and rapid entry in various laparoscopic procedures
    String, A
    Berber, E
    Foroutani, A
    Macho, JR
    Pearl, JM
    Siperstein, AE
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2001, 15 (06): : 570 - 573
  • [2] The use of optical access trocar for rapid and safe entry in laparoscopic bariatric surgery
    Tran, D.
    Halmi, D.
    Kolesnikov, E.
    Rafi, R.
    Pourshojae, H.
    OBESITY SURGERY, 2008, 18 (08) : 956 - 957
  • [3] Experience with the optical access trocar for safe and rapid entry in the performance of laparoscopic gastric bypass
    Barry R. Berch
    Alfonso Torquati
    Rami Edward Lutfi
    William O. Richards
    Surgical Endoscopy And Other Interventional Techniques, 2006, 20 : 1238 - 1241
  • [4] Experience with the optical access trocar for safe and rapid entry in the performance of laparoscopic gastric bypass
    Berch, Barry R.
    Torquati, Alfonso
    Lutfi, Rami Edward
    Richards, William O.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (08): : 1238 - 1241
  • [5] Safe laparoscopic adhesiolysis with optical access trocar and ultrasonic dissection
    D.J. Swank
    H.J. Bonjer
    J. Jeekel
    Surgical Endoscopy And Other Interventional Techniques, 2002, 16 : 1796 - 1801
  • [6] Use of direct optical entry technique as a safe modality for primary trocar insertion for gynaecological laparoscopic procedures in a District General Hospital in UK
    Nagdeve, P.
    Silva, A. D.
    Mudzamiri, T. J. M.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2016, 123 : 221 - 221
  • [7] Direct Optical Access Trocar (Optiview) in laparoscopy: a safe and effective method for laparoscopic access
    Latif, E.
    Al-Sameraaii, A.
    Aslan, P.
    BJU INTERNATIONAL, 2011, 107 : 9 - 9
  • [8] Safe laparoscopic adhesiolysis with optical access trocar and ultrasonic dissection - A prospective study
    Swank, DJ
    Bonjer, HJ
    Jeekel, J
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2002, 16 (12): : 1796 - 1801
  • [9] Experience with optical trocar in performing laparoscopic procedures
    McKernan, JB
    Finley, CR
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2002, 12 (02): : 96 - 99
  • [10] PNEUMOPERITONEUM BY DIRECT TROCAR INSERTION: SAFE LAPAROSCOPIC ACCESS
    Kumar, Rajneesh
    Hastir, Ankur
    Bandlish, M. K.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (15): : 2432 - 2437