Evaluating the impact of different exogenous factors on silk textiles deterioration with use of size exclusion chromatography

被引:0
|
作者
Dominika Pawcenis
Mariusz Smoleń
Monika A. Aksamit-Koperska
Tomasz Łojewski
Joanna Łojewska
机构
[1] Jagiellonian University,Chemistry Faculty
[2] AGH University of Science and Technology,Faculty of Materials Science and Ceramics
来源
Applied Physics A | 2016年 / 122卷
关键词
VOCs; Size Exclusion Chromatography; Silk Fibroin; Size Exclusion Chromatography; Silk Fibre;
D O I
暂无
中图分类号
学科分类号
摘要
Size exclusion chromatography (SEC), especially coupled with multiple angle laser light scattering detector (MALLS) is a powerful tool in diagnostics of deterioration of historic and art objects to evaluate their condition. In this paper, SEC–UV–MALLS–DRI technique was applied to study degradation of silk fibroin samples (Bombyx mori) artificially aged under various conditions: in the presence of oxygen, in different amount of water vapour and in volatile organic products (VOCs), all at temperature of 90 °C. Conditions were chosen in such a way that it mimicked real conditions of textiles’ storing during exhibitions and in show cases. The influence of temperature, moisture and VOCs content on the state of silk textiles was examined with the use of size exclusion chromatography. Pseudo-zero-order Ekenstam equation was applied to study degradation rates of fibroin with use of the approximated values of DP of fibroin.
引用
收藏
相关论文
共 50 条
  • [11] Aqueous phase size exclusion chromatography of polyvinylalcohols of different degrees of hydrolysis
    Lacik, I
    Snaukovà, R
    Simková, B
    Hanzelová, S
    Alexy, P
    MACROMOLECULAR SYMPOSIA, 2003, 197 : 101 - 114
  • [12] THE USE OF SIZE EXCLUSION CHROMATOGRAPHY IN OPTIMIZATION OF DISSOLVING PULP AND VISCOSE MANUFACTURE
    RANTANEN, T
    SUNDQUIST, J
    TAPPI JOURNAL, 1987, 70 (09): : 109 - 111
  • [13] The Use of Size Exclusion Chromatography to Monitor Protein Self-Assembly
    Adawy, Alaa
    Groves, Matthew R.
    CRYSTALS, 2017, 7 (11):
  • [14] Impact of extraction and elution media on non-size effects in size exclusion chromatography of proteins
    Lambrecht, Marlies A.
    Rombouts, Ine
    Van Kelst, Lotte
    Delcour, Jan A.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1415 : 100 - 107
  • [15] Comparison of Different Solvents on the Performance in Size-Exclusion Chromatography of Polylactic Acid
    Kramer, Juliane
    Schmidt, Christian
    Luettgert, Nils
    Loxterkamp, Lisa
    Monks, Kate
    LCGC EUROPE, 2023, 36 (03) : 113 - 114
  • [16] Extracellular vesicle isolation methods: rising impact of size-exclusion chromatography
    Marta Monguió-Tortajada
    Carolina Gálvez-Montón
    Antoni Bayes-Genis
    Santiago Roura
    Francesc E. Borràs
    Cellular and Molecular Life Sciences, 2019, 76 : 2369 - 2382
  • [17] Extracellular vesicle isolation methods: rising impact of size-exclusion chromatography
    Monguio-Tortajada, Marta
    Galvez-Monton, Carolina
    Bayes-Genis, Antoni
    Roura, Santiago
    Borras, Francesc E.
    CELLULAR AND MOLECULAR LIFE SCIENCES, 2019, 76 (12) : 2369 - 2382
  • [18] USE OF A VISCOMETER DETECTOR FOR SIZE EXCLUSION CHROMATOGRAPHY CHARACTERIZATION OF MWD AND BRANCHING IN POLYMERS
    KUO, C
    PROVDER, T
    KOEHLER, ME
    KAH, AF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 191 : 20 - PMSE
  • [19] DESIGN OF A DIFFERENTIAL PRESSURE DETECTOR FOR USE IN THE SIZE-EXCLUSION CHROMATOGRAPHY OF POLYMERS
    MORI, S
    JOURNAL OF CHROMATOGRAPHY, 1993, 637 (02): : 129 - 135
  • [20] Characterization of U-matic videotape deterioration by size exclusion chromatography and pyrolysis gas chromatography/mass spectrometry and the role of adipic acid
    Thiebaut, Benoit
    Vilmont, Leon-Bavi
    Lavedrine, Bertrand
    JOURNAL OF CULTURAL HERITAGE, 2009, 10 (02) : 183 - 197