Development and reliability quantification of a novel test set-up for measuring footwear bending stiffness

被引:8
|
作者
Krumm D. [1 ]
Schwanitz S. [1 ]
Odenwald S. [1 ]
机构
[1] Chemnitz University of Technology, Sports Equipment and Technology, Reichenhainer Str. 70
关键词
Combat boots; Flexibility; Functional design factors; Instrumentation;
D O I
10.1007/s12283-012-0106-7
中图分类号
学科分类号
摘要
Since footwear flexibility impacts functional design factors, numerous studies have investigated footwear bending stiffness. However, the various methods used to measure footwear bending stiffness have some limitations. Hence, the scope of this study was to develop and quantify the reliability of a novel test set-up for measuring footwear bending stiffness. A test set-up consisting of a hydraulic testing machine, a bending apparatus and a fixation unit was created that fulfilled the requirements specified in the initial phase of the study. The test set-up was evaluated by testing 15 different boots in three series of measurements. Bending stiffness of the boots ranged from 0.61 ± 0.03 to 2.38 ± 0.08 Nm/°. Two-way analysis of variance test yielded that the test set-up enabled the reliable measurement of footwear bending stiffness. Relative measurement uncertainty ranged from 1.3 to 6.1 %. © 2012 International Sports Engineering Association.
引用
收藏
页码:13 / 19
页数:6
相关论文
共 50 条
  • [21] Provoked preference test - A new test in the orthoptic set-up
    Paschke, C
    Gaeckle, HC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U624 - U624
  • [22] An experimental set-up to assess knee stiffness: a pilot study
    Samson, W.
    Cheze, L.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 : 2052 - 2053
  • [23] A low frequency electrical test set-up for the reliability assessment of capacitive RF MEMS switches
    van Spengen, WM
    Puers, R
    Mertens, R
    De Wolf, I
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (05) : 604 - 612
  • [24] A novel set-up for positron scattering in gases
    Zecca, A
    Brusa, RS
    Bettonte, M
    Rajch, E
    Mariazzi, S
    Karwasz, GP
    RADIATION PHYSICS AND CHEMISTRY, 2003, 68 (1-2) : 319 - 322
  • [25] Development of HSPECM set-up and its experiments
    Di, SC
    Wu, HB
    Zhao, WS
    Chi, GX
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2005, 15 : 274 - 278
  • [26] A new test set-up for skull fracture characterisation
    Verschueren, P.
    Delye, H.
    Depreitere, B.
    Van Lierde, C.
    Haex, B.
    Berckmans, D.
    Verpoest, I.
    Goffin, J.
    Sloten, J. Vander
    Van der Perre, G.
    JOURNAL OF BIOMECHANICS, 2007, 40 (15) : 3389 - 3396
  • [27] Design Model for the Drive and Actuator of the Test Set-Up of a Novel Flexible Robotic System
    Rauniyar, Aditya
    Roy, Debanik
    Pandit, Pankaj
    Atpadkar, Viinod
    2018 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND COMPUTING RESEARCH (IEEE ICCIC 2018), 2018, : 15 - 21
  • [28] CRYOGENIC VIBRATION TEST SET-UP FOR SPACE QUALIFICATION
    WILDEMAN, KJ
    PLOEGER, GR
    CRYOGENICS, 1989, 29 (05) : 559 - 562
  • [29] Set-up of an ideal landmine test site for GPR
    Daniels, DJ
    Detection and Remediation Technologies for Mines and Minelike Targets X, Pts 1 and 2, 2005, 5794 : 549 - 557
  • [30] NEW ESD TEST SET-UP FOR SPACECRAFT EQUIPMENT
    Daout, B.
    Romero, C.
    Pelissou, P.
    Wolf, K-F. J.
    PROCEEDINGS OF 2016 ESA WORKSHOP ON AEROSPACE EMC (AEROSPACE EMC), 2016,