Strength and fatigue of polyacid-modified restorative materials (compomers)

被引:0
|
作者
Ken G. Boberick
John I. McCool
George R. Baran
机构
[1] Temple University School of Dentistry,
[2] Penn State Great Valley,undefined
[3] Temple University College of Engineering,undefined
关键词
Fatigue; Stainless Steel; Mold; Composite Material; Propagation Rate;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to compare the fatigue behavior of a hybrid composite, four compomers, and two viscous glass ionomers after short- and long-term soaking in distilled water. Bars with dimensions of 30 mm×2 mm×2 mm were formed in stainless steel molds, finished with 600 grit SiC, then soaked for either 24 h or one year, and tested in 3-point flexure at stressing rates between 0.001 and 2500 MPa s−1. Data were plotted as fracture stress vs. stressing rate, and the exponent N in the power law for crack growth rate was computed from the slope of these plots. All compomer and resin composite materials tested exhibited subcritical crack growth (i.e. a reduction in strength with a decrease in stressing rate). Soaking lowered the slope for all materials, that is, increased the crack propagation rate. F2000 exhibited an increase in fracture strength while Hytac and Compoglass exhibited a decrease following long-term soaking in distilled water. Crack-growth exponents obtained from these fatigue data were used to estimate the stresses which would result in a five-year lifetime for these materials.
引用
收藏
页码:613 / 620
页数:7
相关论文
共 50 条
  • [31] Two year clinical performance of a polyacid-modified resin composite and a resin-modified glass-ionomer restorative material
    Brackett, WW
    Browning, WD
    Ross, JA
    Brackett, MG
    OPERATIVE DENTISTRY, 2001, 26 (01) : 12 - 16
  • [32] An investigation into the use of two polyacid-modified composite resins (compomers) and a resin-modified glass poly(alkenoate) cement used to retain orthodontic bands
    Williams, PH
    Sherriff, M
    Ireland, AJ
    EUROPEAN JOURNAL OF ORTHODONTICS, 2005, 27 (03) : 245 - 251
  • [33] Clinical evaluation of a polyacid-modified resin composite (compomer)
    Tyas, MJ
    OPERATIVE DENTISTRY, 1998, 23 (02) : 77 - 80
  • [34] Effect of food-simulating liquids on the flexual strength of composite and polyacid-modified composite restoratives
    Yap, AUJ
    Tan, DTT
    Goh, BKC
    Kuah, HG
    Goh, M
    OPERATIVE DENTISTRY, 2000, 25 (03) : 202 - 208
  • [35] Bond strength of polyacid-modified resins using a new one-step adhesive system
    Oberländer, H
    Friedl, KH
    Schmalz, G
    OPERATIVE DENTISTRY, 2001, 26 (02) : 127 - 133
  • [36] Initial tensile bond strength of resin-modified glass ionomers and polyacid-modified resins on perfused primary dentin
    Kielbassa, AM
    Wrbas, KT
    Hellwig, E
    JOURNAL OF DENTISTRY FOR CHILDREN, 1997, 64 (03): : 183 - +
  • [37] Led and conventional curing of (polyacid-modified) composite resins.
    Koupis, NS
    Verbeeck, RMH
    Marks, LAM
    Martens, LC
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 518 - 518
  • [38] Knoop hardness depth profile of polyacid-modified composite resins
    Koupis, Nikolaos S.
    Vercruysse, Chris W. J.
    Martens, Luc C.
    Verbeeck, Ronald M. H.
    QUINTESSENCE INTERNATIONAL, 2008, 39 (09): : 733 - 743
  • [39] Water sorption/desorption in polyacid-modified composite resins for dentistry
    Nicholson, John W.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (04) : 1713 - 1717
  • [40] Influence of brushing on fluoride release of polyacid-modified composites.
    Plogmann, S
    Attin, T
    Ameling, K
    Hellwig, E
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 820 - 820