Test–Retest Reliability of the Isernhagen Work Systems Functional Capacity Evaluation in Healthy Adults

被引:0
|
作者
M.F. Reneman
S. Brouwer
A. Meinema
P.U. Dijkstra
J.H.B. Geertzen
J.W. Groothoff
机构
[1] University Hospital Groningen,Center for Rehabilitation
[2] University Hospital Groningen,Center for Occupational Health
[3] University of Groningen,Northern Center for Health Care Research
[4] University Hospital Groningen,Department of Oral and Maxillofacial Surgery
来源
关键词
reliability; functional capacity evaluation; disability assessment; occupational rehabilitation;
D O I
暂无
中图分类号
学科分类号
摘要
Aim of this study was to investigate test–retest reliability of the Isernhagen Work System Functional Capacity Evaluation (IWS FCE) in healthy subjects. The IWS FCE consists of 28 tests that reflect work-related activities such as lifting, carrying, bending, etc. A convenience sample of 26 healthy subjects participated in the study. The subjects' mean age was 34.9 years. Two FCE sessions were held within a 2–3 week interval. Descriptives per session, Intra Class Correlations (ICC), limits of agreement, Cohen's Kappa, and percentage of agreement were calculated where appropriate. An ICC of ≥0.75, a Kappa value ≥0.60, and a percentage of absolute agreement of ≥80% were considered acceptable reliability. Acceptable reliability was demonstrated for seven out of nine tests (78%) of the material handling group and the shuttle walk test based on ICC analyses only. Sixteen out of 17 criterion and ceiling tests (94%) showed acceptable reliability based on Kappa values and percentage of agreement. Of these 17 tests, 8 were eligible for further analysis, and of those 8 tests the reliability of one test was acceptable based on ICC analyses (13%). In conclusion, the test–retest reliability of the material-handling group is acceptable. Crude analyses of the ceiling and criterion tests reveal acceptable test–retest reliability of most, but not all, tests.
引用
收藏
页码:295 / 305
页数:10
相关论文
共 50 条
  • [21] Test-Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults
    Jerez-Mayorga, Daniel
    Huerta-Ojeda, Alvaro
    Javier Chirosa-Rios, Luis
    Guede-Rojas, Francisco
    Guzman-Guzman, Iris Paola
    Intelangelo, Leonardo
    Miranda-Fuentes, Claudia
    Delgado-Floody, Pedro
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (13)
  • [22] Test-retest reliability of five frequently used executive tasks in healthy adults
    Soveri, Anna
    Lehtonen, Minna
    Karlsson, Linda C.
    Lukasik, Karolina
    Antfolk, Jan
    Laine, Matti
    APPLIED NEUROPSYCHOLOGY-ADULT, 2018, 25 (02) : 155 - 165
  • [23] Test-Retest Reliability of the Step Watch Activity Monitor Outputs in Healthy Adults
    Mudge, Suzie
    Taylor, Denise
    Chang, Oliver
    Wong, Rosita
    JOURNAL OF PHYSICAL ACTIVITY & HEALTH, 2010, 7 (05): : 671 - 676
  • [24] Test-retest reliability of joint position sense in the elbow among healthy adults
    V. Rider, John
    Valdes, Kristin A.
    JOURNAL OF HAND THERAPY, 2024, 37 (02) : 243 - 249
  • [25] Photopic Negative Response in Healthy Adults: Normative Values and Test-Retest Reliability
    Berezovsky, Adriana
    Bueno, Tatiane N.
    Ferraz, Nivea Nunes
    Sacai, Paula Y.
    Botelho, Gabriel I.
    Fernandes, Arthur
    Coupland, Stuart
    Belfort, Rubens, Jr.
    Sadun, Alfredo A.
    Karanjia, Rustum
    Salomao, Solange Rios
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [26] Test/retest reliability of the vestibular autorotation test in healthy subjects
    O'Leary, DP
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1998, 119 (01) : 147 - 148
  • [27] Test–retest reliability of tip, key, and palmar pinch force sense in healthy adults
    Lin Li
    Yanxia Li
    Changhong Wu
    Xinyan Zhang
    BMC Musculoskeletal Disorders, 21
  • [28] Test-retest reliability of a functional MRI anticipatory anxiety paradigm in healthy volunteers
    Schunck, Therese
    Erb, Gilles
    Mathis, Alexandre
    Jacob, Nathalie
    Gilles, Christian
    Namer, Izzie Jacques
    Meier, Dieter
    Luthringer, Remy
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (03) : 459 - 468
  • [29] An investigation of the inter-rater reliability of the Valpar Joule functional capacity evaluation in healthy adults
    Mitchell, Dawn
    Hancock, Elizabeth
    Alexander, Lyndsay
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2016, 53 (02): : 337 - 345
  • [30] Test-retest reliability of functional MRI
    Tallent, KA
    Ramsey, NF
    Frank, JA
    Moonen, CT
    Weinberger, DR
    INTERNATIONAL JOURNAL OF PSYCHOLOGY, 1996, 31 (3-4) : 12451 - 12451