Reliability and accuracy of segmental bioelectrical impedance analysis for assessing muscle and fat mass in older Europeans: a comparison with dual-energy X-ray absorptiometry

被引:0
|
作者
Katharina Mally
Jens Trentmann
Martin Heller
Manuela Dittmar
机构
[1] Christian-Albrechts-University Kiel,Department of Human Biology, Zoological Institute
[2] University Hospital Schleswig–Holstein Campus Kiel,Department of Diagnostic Radiology
来源
关键词
Muscle mass; Fat mass; Segmental bioelectrical Impedance analysis; Dual-energy X-ray absorptiometry; Limbs; Trunk;
D O I
暂无
中图分类号
学科分类号
摘要
Segmental determination of muscle and fat mass (MM, FM) attains growing importance for judging effects of training and malnutrition in older people. This study evaluated the reliability and accuracy of segmental bioelectrical impedance analysis (sBIA) for use in older people. In 72 (40 men, 32 women) healthy elderly (mean age 69.0 ± 4.8 years), the MM and FM of right and left arm (RA, LA), right and left leg (RL, LL), and trunk were determined by sBIA (BC-418-MA, Tanita) and dual-energy X-ray absorptiometry (DXA) as a reference method. The sBIA provided in both sexes reliable values for limb and truncal MM and FM, except for MM of RL in women. The accuracy of sBIA displayed sex-specific bias. For MM, accurate values were noted for men’s trunk and women’s limbs (except LA). By contrast, MM was significantly underestimated in men’s limbs by 6–18% and overestimated in women’s LA (13%) and trunk (14%). Estimates of FM were accurate for men’s arms as well as women’s legs and trunk. However, FM was significantly overestimated in men’s legs (34–37%) and trunk (60%), but underestimated in women’s arms (27–35%). The proportional deviations of sBIA estimates from DXA values for limbs and trunk were significantly related to the respective MM or FM. The sBIA tends to underestimate MM in men and to overestimate in women. The reverse occurs for FM. The actual equations of the Tanita device may not completely represent the European older population and should be partly revised.
引用
收藏
页码:1879 / 1887
页数:8
相关论文
共 50 条
  • [31] Accuracy of Commercial Body Composition Scales Versus Clinical Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analysis
    Sander, Erica
    Ng, Bennett K.
    Yu, Eric
    Fan, Bo
    Liu, En Yong
    Kazemi, Leila
    Shepherd, John A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 258 - 258
  • [32] Validity and reliability of bioelectrical impedance analysis to estimate body fat percentage against air displacement plethysmography and dual-energy X-ray absorptiometry
    von Hurst, Pamela R.
    Walsh, Daniel C. I.
    Conlon, Cathryn A.
    Ingram, Michelle
    Kruger, Rozanne
    Stonehouse, Welma
    NUTRITION & DIETETICS, 2016, 73 (02) : 197 - 204
  • [33] Accuracy of Commercial Body Composition Scales Versus Clinical Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analysis
    Sander, Erica
    Ng, Bennett K.
    Yu, Eric
    Fan, Bo
    Liu, En Yong
    Kazemi, Leila
    Shepherd, John A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 258 - 258
  • [34] Measuring leg muscle and fat mass in humans: comparison of CT and dual-energy X-ray absorptiometry
    Levine, JA
    Abboud, L
    Barry, M
    Reed, JE
    Sheedy, PF
    Jensen, MD
    JOURNAL OF APPLIED PHYSIOLOGY, 2000, 88 (02) : 452 - 456
  • [35] Validity and agreement between dual-energy X-ray absorptiometry, anthropometry and bioelectrical impedance in the estimation of fat mass in young adults
    Mecherques-Carini, Malek
    Albaladejo-Saura, Mario
    Vaquero-Cristobal, Raquel
    Baglietto, Nicolas
    Esparza-Ros, Francisco
    FRONTIERS IN NUTRITION, 2024, 11
  • [36] Evaluation of Multi-Frequency Bioelectrical Impedance Analysis against Dual-Energy X-ray Absorptiometry for Estimation of Low Muscle Mass in Older Hospitalized Patients
    Nielsen, Rikke Lundsgaard
    Andersen, Aino Leegaard
    Kallemose, Thomas
    Damgaard, Morten
    Bornaes, Olivia
    Juul-Larsen, Helle Gybel
    Strejby Christensen, Louise Westberg
    Jawad, Baker Nawfal
    Andersen, Ove
    Rasmussen, Henrik Hojgaard
    Munk, Tina
    Lund, Trine Meldgaard
    Houlind, Morten Baltzer
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (01)
  • [37] Segmental body composition evaluation by bioelectrical impedance analysis and dual-energy X-ray absorptiometry: Quantifying agreement between methods
    Moore, M. Lane
    Benavides, Marqui L.
    Dellinger, Jacob R.
    Adamson, Brian T.
    Tinsley, Grant M.
    CLINICAL NUTRITION, 2020, 39 (09) : 2802 - 2810
  • [38] New bioelectrical impedance formula for patients with respiratory insufficiency: comparison to dual-energy X-ray absorptiometry
    Kyle, UG
    Pichard, C
    Rochat, T
    Slosman, DO
    Fitting, JW
    Thiebaud, D
    EUROPEAN RESPIRATORY JOURNAL, 1998, 12 (04) : 960 - 966
  • [39] Aging and fat distribution: segmental evaluation with dual-energy x-ray absorptiometry
    Nishizawa, MK
    Ikeda, Y
    Heymsfield, SB
    FASEB JOURNAL, 2004, 18 (04): : A548 - A548
  • [40] MEASUREMENT OF BODY-FAT IN ELDERLY SUBJECTS BY DUAL-ENERGY X-RAY ABSORPTIOMETRY, BIOELECTRICAL IMPEDANCE, AND ANTHROPOMETRY
    SVENDSEN, OL
    HAARBO, J
    HEITMANN, BL
    GOTFREDSEN, A
    CHRISTIANSEN, C
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1991, 53 (05): : 1117 - 1123