Phase-inversion tissue harmonic imaging compared with conventional B-mode ultrasound in the evaluation of pancreatic lesions

被引:0
|
作者
Christian Hohl
Thorsten Schmidt
Patrick Haage
Dagmar Honnef
Marcus Blaum
Gundula Staatz
Rolf W. Guenther
机构
[1] University of Technology of Aachen,Department of Diagnostic Radiology
来源
European Radiology | 2004年 / 14卷
关键词
Ultrasonography; Harmonic imaging; Pancreas; Pancreatic carcinoma; Pancreatitis;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to compare the diagnostic sensitivity, specificity, and image quality of conventional B-mode US (BM) and phase-inversion tissue harmonic imaging (PTHI) regarding pancreatic pathology. In a prospective study, 107 patients, aged between 28 and 85 years, underwent US examinations of the pancreas with both BM and PTHI in a randomly chosen order. As diagnostic reference, either contrast-enhanced CT or MRI examinations of the upper abdomen were obtained in all patients. Sensitivity and specificity were evaluated using the Student’s t test. Differences in overall image quality, lesion conspicuity, fluid–solid differentiation, and delineation of the pancreatic tail were analyzed using Wilcoxon’s signed ranks test and Bowker’s symmetry test. Sixteen of 107 examined patients (15%) were non-diagnostic and excluded due to technical limitations such as abdominal gas. A total of 60 pancreatic lesions (cysts, acute pancreatitis, dilatation of the pancreatic duct, calcifications, and solid tumors) were diagnosed by CT or MRI. Phase-inversion tissue harmonic imaging had a higher sensitivity of 70% (14 of 20) than BM (60%; 24 of 40) for the detection of pancreatic lesions; however, the difference was not statistically significant (p=0.46). In the assessment of lesions <1 cm of size, PTHI had a sensitivity of 70% and BM 46.7%, whereby the difference again was not statistically significant. Phase-inversion tissue harmonic imaging proved to be superior to BM regarding overall image quality (p<0.0001), lesion conspicuity (p=0.0045), and fluid–solid differentiation (p=0.0002), as well as the delineation of the pancreatic tail (p<0.0001). These differences were statistically significant. The statistically significant improvement of image quality with regards to lesion conspicuity, fluid–solid differentiation, and delineation of the pancreatic tail favors the use of PTHI when evaluating the pancreas with US. Sensitivity for pancreatic lesions is increased with PTHI in comparison with conventional sonography (BM), especially in lesions <1 cm in diameter, although the difference was not statistically significant.
引用
收藏
页码:1109 / 1117
页数:8
相关论文
共 50 条
  • [21] B-mode enhancement at phase-inversion US with air-based microbubble contrast agent: Initial experience in humans
    Albrecht, T
    Hoffmann, CW
    Schettler, S
    Overberg, A
    Ilg, M
    von Behren, PL
    Bauer, A
    Wolf, KJ
    RADIOLOGY, 2000, 216 (01) : 273 - 278
  • [22] Tissue harmonic imaging sonography: Evaluation of image quality compared with conventional sonography
    Shapiro, RS
    Wagreich, J
    Parsons, RB
    Stancato-Pasik, A
    Yeh, HC
    Lao, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (05) : 1203 - 1206
  • [23] The Spectrum-Beamformer for Conventional B-Mode Ultrasound Imaging System: Principle, Validation, and Robustness
    Jiang, Chen
    Liu, Chengcheng
    Zhan, Yiqiang
    Ta, Dean
    ULTRASONIC IMAGING, 2022, 44 (2-3) : 59 - 76
  • [24] Evaluation of focal lesions of the supraspinatus tendon with elastosonography: comparison with B-mode ultrasound and magnetic resonance imaging: our experience
    Francavilla, G.
    Sutera, R.
    Iovane, A.
    Candela, F.
    La Tona, G.
    Peritore, G.
    Sanfilippo, A.
    Francavilla, V. C.
    D'Arienzo, M.
    Midiri, M.
    MEDICINA DELLO SPORT, 2012, 65 (04) : 513 - 525
  • [25] Tissue harmonic imaging improves organ visualization in trauma ultrasound when compared with standard ultrasound mode
    Blaivas, M
    DeBehnke, D
    Sierzenski, PR
    Phelan, MB
    ACADEMIC EMERGENCY MEDICINE, 2002, 9 (01) : 48 - 53
  • [26] Evaluation of the intramammary distribution of breast lesions detected by MRI but not conventional second-look B-mode ultrasound using an MRI/ultrasound fusion technique
    Saito, Masayuki
    Banno, Hirona
    Ito, Yukie
    Ido, Mirai
    Goto, Manami
    Ando, Takahito
    Mouri, Yukako
    Kousaka, Junko
    Fujii, Kimihito
    Imai, Tsuneo
    Nakano, Shogo
    Suzuki, Kojiro
    BMC MEDICAL IMAGING, 2024, 24 (01):
  • [27] Usefulness of contrast-enhanced coded phase-inversion harmonic ultrasonagraphy for differential diagnosis of pancreatic diseases and evaluation of chemotherapy
    Kitano, M
    Suetomi, Y
    Maekawa, K
    Sakamoto, H
    Nakaoka, R
    Kawasaki, T
    Kudo, M
    GASTROENTEROLOGY, 2003, 124 (04) : A188 - A188
  • [28] B-mode and Doppler ultrasound imaging of the spleen with canine splenic torsion: A retrospective evaluation
    Saunders, HM
    Neath, PJ
    Brockman, DJ
    VETERINARY RADIOLOGY & ULTRASOUND, 1998, 39 (04) : 349 - 353
  • [29] Evaluation of transmit/receive apodization scheme for hardware implementation used in B-mode ultrasound imaging
    Hechkel, Wided
    Maaref, Brahim
    Hassen, Nejib
    PROCEEDINGS OF THE 2020 17TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD 2020), 2020, : 808 - 813
  • [30] Evaluation and Classification of Incidentally Detected Splenic Lesions Based on B-Mode and Contrast-Enhanced Ultrasound
    Zadeh, Ehsan Safai
    Goerg, Christian
    Post, Clemens
    Alhyari, Amjad
    Trenker, Corinna
    Dietrich, Christoph F.
    Findeisen, Hajo