Reagentless amperometric glucose biosensor based on the immobilization of glucose oxidase on a ferrocene@NaY zeolite composite

被引:0
|
作者
Junping Dong
Xiaojuan Zhou
Hongbin Zhao
Jiaqiang Xu
Youbao Sun
机构
[1] Shanghai University,Department of Chemistry, College of Science
[2] Chinese Academy of Sciences,State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology
[3] Shanghai University,School of Materials Science and Engineering
[4] Shimadzu International Trading (Shanghai) Co.Ltd,undefined
来源
Microchimica Acta | 2011年 / 174卷
关键词
NaY zeolite; Ferrocene; Glucose oxidase; Amperometric biosensor;
D O I
暂无
中图分类号
学科分类号
摘要
Ferrocene (Fc) was encapsulated in the cavities of a NaY zeolite by vapor diffusion via sublimation at below 100 °C. The resulting Fc@NaY zeolite composite was investigated by power X-ray diffraction, diffuse reflectance UV–vis and FT-IR spectroscopy, and by cyclic voltammetry. The results indicated that Fc was encapsulated into the zeolite whose microporous structure had remained intact. The Fc in the silica matrix had retained its electroactivity and did not leach out. A glucose biosensor was obtained by immobilization of the modified zeolite and glucose oxidase on a carbon paste electrode. It displays a linear response to glucose (from 0.8 μM to 4.0 mM), a detection limit of 0.2 μM, and a response time of 4 s. The good performance of the biosensor is ascribed to the biocompatibility of the zeolite and presence of Fc which facilitates the electron transfer from the enzyme to the surface of the electrode.
引用
收藏
页码:281 / 288
页数:7
相关论文
共 50 条
  • [31] IMMOBILIZATION OF GLUCOSE OXIDASE IN SILICA SOL-GEL FILM FOR APPLICATION TO BIOSENSOR AND AMPEROMETRIC DETERMINATION OF GLUCOSE
    Demirkiran, Nizamettin
    Ekinci, Ergun
    Asilturk, Meltem
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2012, 57 (04) : 1336 - 1339
  • [32] Glucose Biosensor Based on Immobilization of Glucose Oxidase on Porous Screen Printed Electrodes
    Bian, Li-Jun
    Wang, Lu
    Ye, Yin-Jian
    Liu, Xiao-Xia
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (07): : 6201 - 6210
  • [33] Amperometric glucose biosensor based on self-assembling glucose oxidase on carbon nanotubes
    Liu, GD
    Lin, YH
    ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (02) : 251 - 256
  • [34] Amperometric glucose biosensor based on a gold nanorods/cellulose acetate composite film as immobilization matrix
    Ren, Xiangling
    Chen, Dong
    Meng, Xianwei
    Tang, Fangqiong
    Du, Aiming
    Zhang, Lin
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 72 (02) : 188 - 192
  • [35] AMPEROMETRIC BIOSENSOR FOR GLUCOSE BASED ON NAFION LOADED WITH REDOX COUPLES AND GLUCOSE-OXIDASE
    BELANGER, D
    VAILLANCOURT, M
    FORTIER, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 1 - ANYL
  • [36] Amperometric glucose biosensor based on a triangular silver nanoprisms/chitosan composite film as immobilization matrix
    Shi, Wentao
    Ma, Zhanfang
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (03): : 1098 - 1103
  • [37] The use of different glucose oxidases for the development of an amperometric reagentless glucose biosensor based on gold nanoparticles covered by polypyrrole
    German, Natalija
    Kausaite-Minkstimiene, Asta
    Ramanavicius, Arunas
    Semashko, Tatiana
    Mikhailova, Raisa
    Ramanaviciene, Almira
    ELECTROCHIMICA ACTA, 2015, 169 : 326 - 333
  • [38] A reagentless glucose biosensor based on glucose oxidase entrapped into osmium-complex modified polypyrrole films
    Reiter, S
    Habermüller, K
    Schuhmann, W
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (2-3) : 150 - 156
  • [39] Reagentless glucose biosensor based on the direct electrochemistry of glucose oxidase on carbon nanotube-modified electrodes
    Luo, Xiliang
    Killard, Anthony J.
    Smyth, Malcolm R.
    ELECTROANALYSIS, 2006, 18 (11) : 1131 - 1134
  • [40] Evaluation of Some Redox Mediators in the Design of Reagentless Amperometric Glucose Biosensor
    Kausaite-Minkstimiene, Asta
    Mazeiko, Viktor
    Ramanaviciene, Almira
    Oztekin, Yasemin
    Solak, Ali Osman
    Ramanavicius, Arunas
    ELECTROANALYSIS, 2014, 26 (07) : 1528 - 1535