Comparison of computerized methods for detecting the ventilatory thresholds

被引:0
|
作者
Edil Luis Santos
Antonio Giannella-Neto
机构
[1] Federal University of Rio de Janeiro,Biomedical Engineering Program, Graduate School of Engineering
来源
关键词
Anaerobic threshold; Automatic detection; Progressive exercise; Maximum oxygen uptake;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to compare computerized automatic methods to detect the ventilatory threshold (VT). Thirty apparently healthy and physically active volunteers [22.5 (6.5) years; 1.72 (0.08) m; 71.9 (8.5) kg] were submitted to a progressive and maximal cycle exercise. The gas exchange was monitored breath-by-breath with a fast gas analyser. The VT and respiratory compensation (RC) were automatically detected based on the respiratory exchange ratio, the ventilatory equivalent for O2 and the ventilatory equivalent for CO2, pulmonary ventilation, end-tidal PO2 and PCO2, and v-slope. In addition, VT and RC were also determined independently by visual inspection by two experienced investigators, and the results were compared with those of the automatic procedures. The automatic VT averaged 77% of the maximal V̇O2 and the RC 88%. The agreement between the experienced observers was very close [mean difference: 44.4 (16.1) ml, r=0.94, not significant]. Data were expressed as the mean value together with the standard deviation in each case. The automatic and visual inspection procedures did not present significant differences, resulting in 29.6 (29.6) ml with a reliability of r=0.86. All methods were significantly correlated for VT and RC (r=0.93 on average, P<0.01). ANOVA did not show differences between either the VT methods (P=0.131) or the RC methods (P=0.41). In conclusion, the present study has compared several simultaneous breath-by-breath ergospirometric methods that are used to describe the anaerobic threshold, showing high confidence when compared to visual inspection. No statistical differences were found between the VT and RC techniques for physically active subjects indicating that these methods may be equally effectively employed.
引用
收藏
页码:315 / 324
页数:9
相关论文
共 50 条
  • [11] COMPARISON OF EFFECTS OF 2 INTERVAL-TRAINING PROGRAMS ON LACTATE AND VENTILATORY THRESHOLDS
    BURKE, J
    THAYER, R
    BELCAMINO, M
    BRITISH JOURNAL OF SPORTS MEDICINE, 1994, 28 (01) : 18 - 21
  • [12] Exercise Testing in Children: Comparison in Ventilatory Thresholds Changes with Interval-Training
    Mucci, Patrick
    Baquet, Georges
    Nourry, Cedric
    Deruelle, Fabien
    Berthoin, Serge
    Fabre, Claudine
    PEDIATRIC PULMONOLOGY, 2013, 48 (08) : 809 - 816
  • [13] DETECTING UROPATHOGENS IN A UROGYNECOLOGIC POPULATION: A COMPARISON OF UTI DIAGNOSTIC THRESHOLDS
    Price, T.
    Hilt, E.
    Dune, T.
    Brincat, C.
    Brubaker, L.
    Mueller, E.
    Schreckenberger, P.
    Wolfe, A.
    NEUROUROLOGY AND URODYNAMICS, 2017, 36 : S196 - S197
  • [14] THERMAL DISCRIMINATION THRESHOLDS - A COMPARISON OF DIFFERENT METHODS
    CLAUS, D
    HILZ, MJ
    NEUNDORFER, B
    ACTA NEUROLOGICA SCANDINAVICA, 1990, 81 (06): : 533 - 540
  • [15] COMPARISON OF 2 METHODS FOR MEASURING THERMAL THRESHOLDS
    JAMAL, GA
    HANSEN, S
    BALLANTYNE, JP
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1991, 54 (02): : 187 - 188
  • [16] Is the Tyme Wear Smart Shirt Reliable and Valid at Detecting Personalized Ventilatory Thresholds in Recreationally Active Individuals?
    Gouw, Aaron H.
    Van Guilder, Gary P.
    Cullen, Gillian G.
    Dalleck, Lance C.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (03)
  • [17] Detecting mechanical breakpoints during treadmill-based graded exercise test: Relationships to ventilatory thresholds
    Li, Siu Nam
    Peeling, Peter
    Hansen, Clint
    Van Alsenoy, Ken
    Ryu, Joong Hyun
    Girard, Olivier
    EUROPEAN JOURNAL OF SPORT SCIENCE, 2022, 22 (07) : 1025 - 1034
  • [18] COMPARISON OF SEVERAL COMPUTERIZED DISTRIBUTION PLANNING METHODS
    WILLIS, HL
    NORTHCOTEGREEN, JED
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (01): : 233 - 240
  • [19] Comparison of Performances for Computerized Ionospheric Tomography Methods
    Yenen, Sinem Deniz
    Arikan, Feza
    Arikan, Orhan
    32ND IEEE SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE, SIU 2024, 2024,
  • [20] COMPARISON OF DIAGNOSTIC CODING BY MANUAL AND COMPUTERIZED METHODS
    HOWELL, RW
    BRITISH JOURNAL OF PREVENTIVE & SOCIAL MEDICINE, 1971, 25 (04): : 225 - &