An animal model for checking instrument sterilisation

被引:0
|
作者
Philip P Mortimer
机构
[1] Director,
[2] Sexually Transmitted and Blood Borne Virus Laboratory,undefined
[3] Central Public Health Laboratory,undefined
关键词
D O I
10.1038/sj.bdj.4800844
中图分类号
学科分类号
摘要
In vitro assessment of sterilisation and disinfection processes using bacteria as test organisms are the basis of recommendations for clinical practice. It has been difficult to test efficacy against viruses, or to determine the effect of blood and other body fluids.We used duck hepatitis B virus which is similar to the human agent to test the efficacy of autoclaving on dental syringes. Low levels of virus (sufficient to infect 1/16 ducklings) survived high temperature/short cycle autoclaving of syringes which had been contaminated to mimic 'in use' conditions.Electronmicroscopy showed extensive biofilm formation on the luminal surface of used dental syringes, and this protects organisms against destruction by chemical and physical agents. It is also difficult to remove by cleaning.We believe that routine cleaning procedures must be rigorous and that clinical guidelines for sterilisation and disinfection should incorporate a significant margin in excess of the conditions based on conventional in vitro tests.
引用
收藏
页码:608 / 608
相关论文
共 50 条
  • [41] PORTABLE INSTRUMENT FOR CHECKING TEETH ON LARGE GEAR RINGS
    POZDNYAKOV, VP
    SHERESHEVSKII, LM
    MEASUREMENT TECHNIQUES, 1979, 22 (03) : 340 - 341
  • [42] ESOPHAGEAL STETHOSCOPE, A SIMPLE INSTRUMENT FOR THE PEROPERATIVE CHECKING UP
    BARRAYA, L
    MINICONI, D
    PRESSE MEDICALE, 1960, 68 (45): : 1667 - 1668
  • [43] INSTRUMENT FOR CHECKING THE DIAMETER AND WALL THICKNESS OF GLASS TUBING
    KURBATOV, EV
    GAI, EL
    AKIMOCHKIN, LI
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1979, 46 (10): : 593 - 595
  • [44] INSTRUMENT FOR CHECKING PPLL-2 ENGRAVED STRAIGHTEDGES
    ZEIGMAN, LL
    LEONOV, VV
    MEASUREMENT TECHNIQUES USSR, 1983, 26 (06): : 463 - 466
  • [45] AN INSTRUMENT FOR CHECKING THE DIAMETERS OF LIGHT GUIDES BY COMPARISON WITH A STANDARD
    ZAVITNEVICH, YV
    KOZLOV, AA
    MIROVITSKAYA, SD
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1984, 27 (01) : 234 - 237
  • [46] INSTRUMENT FOR CHECKING THE THICKNESS OF MATERIALS BY MEANS OF RADIOACTIVE PREPARATIONS
    KARPOV, VM
    INDUSTRIAL LABORATORY, 1960, 26 (11): : 1498 - 1502
  • [47] Laparoscopic bowel injury: role of the site and the instrument type: study with an animal model
    C. Tsigris
    A. Tsechpenakis
    N. Nikiteas
    I. Tzogios
    I. S. Vlachos
    Th. Diamantis
    D. N. Perrea
    Surgical Endoscopy, 2008, 22 : 2164 - 2167
  • [48] Laparoscopic bowel injury: role of the site and the instrument type: study with an animal model
    Tsigris, C.
    Tsechpenakis, A.
    Nikiteas, N.
    Tzogios, I.
    Vlachos, I. S.
    Diamantis, Th.
    Perrea, D. N.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2008, 22 (10): : 2164 - 2167
  • [49] An integration of model checking with automated proof checking
    Rajan, S
    Shankar, N
    Srivas, MK
    COMPUTER AIDED VERIFICATION, 1995, 939 : 84 - 97
  • [50] Is it model checking, property checking, or language containment?
    不详