Micro-liquid chromatography mass spectrometry for the analysis of antineoplastic drugs from wipe samples

被引:0
|
作者
Terence Hetzel
Claudia vom Eyser
Jochen Tuerk
Thorsten Teutenberg
Torsten C. Schmidt
机构
[1] Institut für Energie- und Umwelttechnik e. V. (IUTA,Instrumental Analytical Chemistry
[2] Institute of Energy and Environmental Technology),undefined
[3] University of Duisburg-Essen,undefined
来源
Analytical and Bioanalytical Chemistry | 2016年 / 408卷
关键词
Extraction efficiency; Large volume injection; Peak distortion; Method development and validation;
D O I
暂无
中图分类号
学科分类号
摘要
A fast quantification method for the determination of 11 antineoplastic drugs from wipe samples was developed using micro-scale liquid chromatography in combination with tandem mass spectrometry. The extraction efficiency from the wipes has been investigated using different extraction solvents. The results indicate that a mixture of 70/30 water/isopropanol (v/v) acidified with 0.1 % formic acid is suitable to desorb the antineoplastic drugs with sufficient recovery between 80 and 120 %. Compared to conventional liquid chromatography, the total analysis time can be reduced to 2.25 min using a 50 × 0.3 mm column at a flow rate of 25 μL min−1. Ion source parameters as well as the injection volume were optimized to ensure the highest sensitivity. The results of method validation showed an instrumental limit of quantification between 0.0068 and 0.0488 ng mL−1 using an injection volume of 4.25 μL estimated by the signal to noise ratio. Moreover, the retention time repeatability was determined with a maximum relative standard deviation of 0.4 %.
引用
收藏
页码:8221 / 8229
页数:8
相关论文
共 50 条
  • [41] Development of a Nonradioactive Platelet Serotonin Uptake and Release Assay by Micro-Liquid Chromatography Tandem Mass Spectrometry Using Minimal Blood Volume
    Chan, Siaw Li
    Yi, Xin
    Wysocki, Emily
    Bridgman, Rachael
    Gutierrez, Jocelyn
    Mikrut, Krzysztof
    Leung, Edward Ki-Yun
    Yeo, Kiang-Teck J.
    Miller, Jonathan L.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2019, 152 (06) : 718 - 724
  • [42] Quantification of antiretroviral drugs in dried blood spot samples by means of liquid chromatography/tandem mass spectrometry
    Koal, T
    Burhenne, H
    Römling, R
    Svoboda, M
    Resch, K
    Kaever, V
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (21) : 2995 - 3001
  • [43] Enantiomeric fraction determination of chiral drugs in environmental samples using chiral liquid chromatography and mass spectrometry
    Fu, Yandi
    Borrull, Francesc
    Marce, Rosa Maria
    Fontanals, Naria
    TRENDS IN ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2021, 29
  • [44] Microcolumn liquid chromatography electrospray ionization tandem mass spectrometry - Analysis of immunological samples
    McCormack, AL
    Eng, JK
    DeRoos, PC
    Rudensky, AY
    Yates, JR
    BIOCHEMICAL AND BIOTECHNOLOGICAL APPLICATIONS OF ELECTROSPRAY IONIZATION MASS SPECTROMETRY, 1996, 619 : 207 - 225
  • [45] Capillary liquid chromatography/electrospray mass spectrometry for analysis of steroid sulfates in biological samples
    Liu, S
    Griffiths, WJ
    Sjövall, J
    ANALYTICAL CHEMISTRY, 2003, 75 (04) : 791 - 797
  • [46] Simultaneous and systematic analysis of cytostatic drugs in wastewater samples by ultra-high performance liquid chromatography tandem mass spectrometry
    Santana-Viera, S.
    Hernandez-Arencibia, P.
    Sosa-Ferrera, Z.
    Santana-Rodriguez, J. J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1110 : 124 - 132
  • [47] The analysis of dried blood spot samples using liquid chromatography tandem mass spectrometry
    Keevil, Brian G.
    CLINICAL BIOCHEMISTRY, 2011, 44 (01) : 110 - 118
  • [48] Analysis of meat samples for anabolic steroids residues by liquid chromatography/tandem mass spectrometry
    Blasco, Cristina
    Van Poucke, Christof
    Van Peteghem, Carlos
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) : 230 - 239
  • [49] Determination of chlormequat in fruit samples by liquid chromatography-electrospray-mass spectrometry/mass spectrometry
    Castro, R
    Moyano, E
    Galceran, MT
    JOURNAL OF AOAC INTERNATIONAL, 2001, 84 (06) : 1903 - 1908
  • [50] Analysis of drugs of abuse in wastewater by hydrophilic interaction liquid chromatography–tandem mass spectrometry
    Alexander L. N. van Nuijs
    Isabela Tarcomnicu
    Lieven Bervoets
    Ronny Blust
    Philippe G. Jorens
    Hugo Neels
    Adrian Covaci
    Analytical and Bioanalytical Chemistry, 2009, 395 : 819 - 828