The verification phase and reliability of physiological parameters in peak testing of elite wheelchair athletes

被引:0
|
作者
Christof A. Leicht
Keith Tolfrey
John P. Lenton
Nicolette C. Bishop
Victoria L. Goosey-Tolfrey
机构
[1] Loughborough University,School of Sport, Exercise, and Health Sciences, The Peter Harrison Centre for Disability Sport
来源
关键词
Spinal cord injury; Paralympic; Exercise testing; Aerobic capacity;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was (1) to examine the value of a verification phase (VER) in a peak testing protocol and (2) to assess the reliability of peak physiological variables in wheelchair athletes. On two separate days, eight tetraplegic (TETRA), eight paraplegic (PARA) and eight non-spinal cord-injured (NON-SCI) athletes performed treadmill ergometry, consisting of a graded exercise test to exhaustion (GXT) followed by a VER. Peak oxygen uptake \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ \left( {\dot{V}{\text{O}}_{{ 2 {\text{peak}}}} } \right) $$\end{document} was compared (1) between GXT and VER and (2) between test days. \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ \dot{V}{\text{O}}_{{2{\text{peak}}}} $$\end{document} did not differ between GXT and VER (P = 0.27), and coefficients of variation between GXT and VER were in the range of 2.9 and 6.4 % for all subgroups. Coefficients of variation of \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ \dot{V}{\text{O}}_{{2{\text{peak}}}} $$\end{document} between test days were 9.3 % (TETRA), 4.5 % (PARA) and 3.3 % (NON-SCI). It is therefore concluded that whilst a VER can be used for a more robust determination of \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ \dot{V}{\text{O}}_{{2{\text{peak}}}} $$\end{document}, a deviation of up to ~6 % between GXT and VER should be considered as acceptable. For between-day analyses, relatively large changes in \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ \dot{V}{\text{O}}_{{2{\text{peak}}}} $$\end{document} are required to confirm “true” differences, especially in TETRA athletes. This may be due to their lower aerobic capacity, which results in a larger relative variation compared with the other subgroups.
引用
收藏
页码:337 / 345
页数:8
相关论文
共 23 条
  • [21] Medical considerations for supporting elite athletes during the post-peak phase of the New Zealand COVID-19 pandemic: a New Zealand sporting code consensus
    Hamilton, Bruce
    Anderson, Lynley
    Anglem, Nat
    Armstrong, Stuart
    Baker, Simon
    Beable, Sarah
    Burt, Peter
    Coleman, Lynne
    Doughty, Rob
    Edwards, Tony
    Exeter, Dan
    Fulcher, Mark
    Kara, Stephen
    Mayhew, John
    Mayhew, Sam
    Milne, Chris
    O'Neill, Brendan
    Osborne, Hamish
    Parnell, Melinda
    Pearson, Jake
    Rasmussen, Karen
    Scheffer, Judikje
    Swan, Martin
    Thomas, Mark
    Gerrard, David
    NEW ZEALAND MEDICAL JOURNAL, 2020, 133 (1517) : 107 - 116
  • [22] Comparison of Peak Oxygen Uptake and Test-Retest Reliability of Physiological Parameters between Closed-End and Incremental Upper-Body Poling Tests
    Baumgart, Julia K.
    Skovereng, Knut
    Sandbakk, Oyvind
    FRONTIERS IN PHYSIOLOGY, 2017, 8
  • [23] Comparison of Peak Oxygen Uptake and Test-Retest Reliability of Physiological Parameters between Closed-End and Incremental Upper-Body Poling Tests (vol 8, 557, 2017)
    Baumgart, Julia K.
    Skovereng, Knut
    Sandbakk, Oyvind
    FRONTIERS IN PHYSIOLOGY, 2018, 9