To what extent can 3D model replicate dimensions of individual mitral valve prolapse?

被引:0
|
作者
Takashi Shirakawa
Masao Yoshitatsu
Yasushi Koyama
Akira Kurata
Toru Miyoshi
Hiroki Mizoguchi
Takafumi Masai
Koichi Toda
Yoshiki Sawa
机构
[1] Kansai Rosai Hospital,Department of Cardiovascular Surgery
[2] Osaka University Graduate School of Medicine,Department of Cardiovascular Surgery
[3] Sakurabashi Watanabe Hospital,Department of Diagnostic Radiology and Cardiology
[4] Ehime University Graduate School of Medicine,Department of Radiology
[5] Okayama University Graduate School of Medicine,Department of Cardiovascular Medicine
[6] Sakurabashi Watanabe Hospital,Department of Cardiovascular Surgery
来源
关键词
3D model; Prototyping; Mitral valve; Prolapse; Surgical simulation;
D O I
暂无
中图分类号
学科分类号
摘要
Determining the complex geometry of mitral valve prolapse is often difficult. We constructed 3D models of six prolapsed mitral valves for surgical assessment, and evaluated how accurately the models could replicate individual valve dimensions. 3D polygon data were constructed based on an original segmentation method for computed tomography images. The model’s replication performance was confirmed via dimensional comparison between the actual hearts during surgery and those models. The results revealed that the prolapsed segments matched in all cases; however, torn chordae were replicated in four cases. The mean height differences were 0.0 mm (SD 1.6, range − 2 to + 2 mm) for the anterolateral side, 0.0 mm (SD 1.7, range − 2 to + 2 mm) for the prolapsed leaflet center, and − 1.5 mm (SD 0.6, range − 1 to − 2 mm) for the posteromedial side. Regression analysis showed a strong and positive correlation, and Bland–Altman plots indicated quantitative similarity of the models to the actual hearts. We concluded that our 3D valve models could replicate the actual mitral valve prolapses within acceptable dimensional differences. Our concepts are useful for better 3D valve creation and better surgical planning with reliable 3D valve models.
引用
收藏
页码:348 / 355
页数:7
相关论文
共 50 条
  • [31] Mitral valve area during percutaneous mitral valve repair: the need of 3D planimetric quantification
    Squeri, A.
    Nerla, R.
    Ruggerini, S.
    Nucifora, G.
    Micari, A.
    Castriota, F.
    Cremonesi, A.
    EUROPEAN HEART JOURNAL, 2018, 39 : 1060 - 1060
  • [32] 3D MITRAL VALVE QUANTITATION PREDICTS PROCEDURAL SUCCESS DURING TRANSCATHETER MITRAL VALVE REPAIR
    Oguz, Didem
    Eleid, Mackram
    Mankad, Sunil
    Pislaru, Sorin
    Maalouf, Youssef
    Nkomo, Vuyisile
    Holmes, David
    Reeder, Guy
    Rihal, Charanjit
    Thaden, Jeremy
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1543 - 1543
  • [33] 3D TOE-Guided Mitral Valve-in-Valve Procedure
    Duncan, Alison
    Quarto, Cesare
    Davies, Simon
    Moat, Neil
    CARDIOLOGY, 2016, 134 (02) : 307 - 308
  • [34] Assessment of the mitral valve annulus by 3D echocardiography in children
    Cardin, C.
    Arnaudis, B.
    Hascoet, S.
    Amadieu, R.
    Seguela, P. E.
    Dulac, Y.
    Leobon, B.
    Acar, P.
    EUROPEAN HEART JOURNAL, 2010, 31 : 184 - 184
  • [35] Localizing Mitral Valve Perforations With 3D Transesophageal Echocardiography
    Bhave, Nicole M.
    Addetia, Karima
    Spencer, Kirk T.
    Weinert, Lynn
    Jeevanandam, Valluvan
    Lang, Roberto M.
    JACC-CARDIOVASCULAR IMAGING, 2013, 6 (03) : 407 - 410
  • [36] 3D PRINTED VALVE MODELS REPLICATE IN VIVO BICUSPID AORTIC VALVE PEAK PRESSURE DROPS
    Gill, Harminder
    Fernandes, Joao F.
    Bissell, Malenka
    Wang, Shu
    Sotelo, Julio
    Urbina, Jesus
    Uribe, Sergio
    Nordsletten, David
    Myerson, Saul
    Rhode, Kawal
    Rajani, Ronak
    Lamata, Pablo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1636 - 1636
  • [37] Measurement of mitral valve area in patients with mitral stenosis by 3D echocardiography: A comparison between direct planimetry on 3D zoom and 3D quantification
    Sadeghian, Hakimeh
    Rezvanfard, Mehrnaz
    Jalali, Arash
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (08): : 1509 - 1514
  • [38] Role of 3D Echocardiography Derived Color-Coded Parametric Models of the Mitral Valve in Differential Diagnosis of Prolapse and Billowing
    Addetia, Karima
    Weinert, Lynn
    Salgo, Ivan S.
    Lang, Roberto M.
    Mor-Avi, Victor
    2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 1143 - 1146
  • [39] Biventricular reverse remodeling and relationship with mitral valve prolapse after transcatheter closure of ASD secundum, a 3D echocardiographic study
    El-Sisi, Amal
    Dabour, Shaheen
    Fattouh, Aya M.
    Assar, Effat
    Naguib, Rasha
    AbdelMassih, Antoine Fakhry
    JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH, 2020, 12 (01) : 15 - 19
  • [40] Utility of new real-time 3D transthoracic echocardiography in evaluation of mitral valve prolapse - Comparison with transesophageal echocardiography
    Hirata, K
    Otsuka, R
    Oe, Y
    Fujikura, K
    DiTullio, MR
    Homma, S
    CIRCULATION, 2003, 108 (17) : 551 - 551