Comparison between terminal slope rate constant and "slope/intercept" as measures of glomerular filtration rate using the single-compartment simplification

被引:0
|
作者
A. M. Peters
B. L. Henderson
D. Lui
机构
[1] Department of Nuclear Medicine,
[2] Box 170,undefined
[3] Addenbrookes Hospital,undefined
[4] Hills Road,undefined
[5] Cambridge CB2 2QQ,undefined
[6] UK,undefined
[7] Department of Nuclear Medicine,undefined
[8] Harley Street Clinic,undefined
[9] London,undefined
[10] W19 8BJ,undefined
[11] UK,undefined
[12] Institute of Nuclear Medicine,undefined
[13] Middlesex Hospital,undefined
[14] London,undefined
[15] W17 3AA,undefined
[16] UK,undefined
来源
关键词
Glomerular filtration rate 51Cr-EDTA Renal clearance;
D O I
暂无
中图分类号
学科分类号
摘要
Several whole-body variables are available for indexing glomerular filtration rate (GFR), including extracellular fluid volume (ECF volume, ECV), which has the advantage that GFR based only on the terminal exponential, α2, of the chromium-51 ethylene diamine tetra-acetic acid (51Cr-EDTA) plasma clearance curve is a measure already indexed for ECV. This slope-only method, however, is open to the theoretical criticism of a lack of robustness not present in the more conventional slope/intercept method, which generates GFR in absolute units before indexation to body surface area (BSA). To further evaluate the slope-only method, a large database of routine three-sample GFR measurements, based on 51Cr-EDTA, was analysed with the aim of comparing GFR/BSA with GFR/ECV, identifying the main sources of error in their respective measurements and explaining why they might be discrepant. The database was subdivided into 304 patients (group A) in whom the correlation coefficient of the fit to the three data points was greater than 0.99 and 31 patients in whom it was less than 0.99 (noisy data; group B). There was modest agreement between GFR/BSA and GFR/ECV in group A (r=0.77; mean ratio 1.01±0.21). The difference between them correlated significantly with BSA (r=0.52; P<0.001), as would be expected given that small individuals have a relatively high BSA. Subdividing group A into four subgroups stratified according to BSA led to a slight improvement in the correlation between GFR/BSA and GFR/ECV. Because an error in α2 is balanced by an opposing error in the intercept (which leads to a change in distribution volume in the opposite direction), and therefore impacts on both GFR/BSA and GFR/ECV, whereas an error in administered dose affects only GFR/BSA, it is possible to evaluate such errors by examining the respective relationships of GFR/BSA and GFR/ECV with indexed ECV. In group A, GFR/BSA correlated positively with ECV/1.73 m2, not surprisingly as ECV/BSA is effectively the ratio GFR/BSA to GFR/ECV, while GFR/ECV correlated negatively with ECV/1.73 m2. This implies that errors other than α2, probably principally in administered dose, were as important as errors in α2. This conclusion was supported by disappearance of the positive correlation between GFR/BSA and ECV/BSA in group B, brought about by the greater errors in α2 in this group. This study suggests that, because of the effects of errors in the slope/intercept method that do not affect α2, GFR based on slope only is at least as robust as that based on slope/intercept.
引用
收藏
页码:320 / 326
页数:6
相关论文
共 50 条
  • [1] Comparison between terminal slope rate constant and "slope/intercept" as measures of glomerular filtration rate using the single-compartment simplification
    Peters, AM
    Henderson, BL
    Lui, D
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (03) : 320 - 326
  • [2] Using the slope-only technique and estimated glomerular filtration rate for checking the reliability of slope-intercept measurement of glomerular filtration rate
    Bird, Nicholas J.
    Peters, Christina
    Michell, A. Robert
    Peters, A. Michael
    NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (12) : 1086 - 1092
  • [3] Comparison of slope-intercept with single plasma sample methods in estimating glomerular filtration rate using radionuclides
    Osman, Abdelbagi Omer
    Elmadani, Ahmed Elkhidir
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2014, 25 (02) : 321 - 325
  • [4] The effect of measurement errors on glomerular filtration rate: a comparison of the slope-intercept and slope-only methods
    Holness, J. L.
    Warwick, J. M.
    Fleming, J. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S358 - S358
  • [5] Calculating the precision of slope-intercept glomerular filtration rate measurements
    Memmott, Matthew J.
    Lawson, Richard S.
    NUCLEAR MEDICINE COMMUNICATIONS, 2022, 43 (08) : 959 - 966
  • [6] Correction of the slope-intercept method for the measurement of glomerular filtration rate
    Blake, Glen M.
    Barnfield, Mark C.
    Burniston, Maria T.
    Fleming, John S.
    Cosgriff, Philip S.
    Siddique, Musib
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (12) : 1277 - 1283
  • [7] The effect of measurement errors on glomerular filtration rate: a comparison of the slope-intercept, single-sample and slope-only methods
    Holness, J.
    Fleming, J.
    Warwick, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S19 - S19
  • [8] Robustness of slope-intercept versus slope-only for measurement of glomerular filtration rate
    Peters, AM
    NUCLEAR MEDICINE COMMUNICATIONS, 2001, 22 (01) : 115 - 117
  • [9] Errors in measurement of glomerular filtration rate using the slope-intercept technique and their identification
    Oliveira, Ana
    Conway, Lauren
    Heraghty, Neil
    Peters, A. Michael
    NUCLEAR MEDICINE COMMUNICATIONS, 2024, 45 (01) : 51 - 60
  • [10] COMPARISON OF MEASUREMENT OF GLOMERULAR-FILTRATION RATE BY SINGLE SAMPLE, PLASMA DISAPPEARANCE SLOPE INTERCEPT AND OTHER METHODS
    TEPE, PG
    TAUXE, WN
    BAGCHI, A
    REZENDE, P
    KRISHNAIAH, PR
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1987, 13 (01): : 28 - 31