Interplay between driveline infection, vessel wall inflammation, cerebrovascular events and mortality in patients with left ventricular assist device

被引:0
|
作者
Juliane Hupe
Hans Worthmann
Kim K. Ravenberg
Gerrit M. Grosse
Johanna Ernst
Axel Haverich
Frank M. Bengel
Karin Weissenborn
Jan D. Schmitto
Jasmin S. Hanke
Thorsten Derlin
Maria M. Gabriel
机构
[1] Hannover Medical School,Department of Neurology
[2] Hannover Medical School,Department of Cardiac, Thoracic, Transplantation and Vascular Surgery
[3] Hannover Medical School,Department of Nuclear Medicine
来源
Scientific Reports | / 13卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
In patients with left ventricular assist device (LVAD), infections and thrombotic events represent severe complications. We investigated device-specific local and systemic inflammation and its impact on cerebrovascular events (CVE) and mortality. In 118 LVAD patients referred for 18F-FDG-PET/CT, metabolic activity of LVAD components, thoracic aortic wall, lymphoid and hematopoietic organs, was quantified and correlated with clinical characteristics, laboratory findings, and outcome. Driveline infection was detected in 92/118 (78%) patients by 18F-FDG-PET/CT. Activity at the driveline entry site was associated with increased signals in aortic wall (r = 0.32, p < 0.001), spleen (r = 0.20, p = 0.03) and bone marrow (r = 0.20, p = 0.03), indicating systemic interactions. Multivariable analysis revealed independent associations of aortic wall activity with activity of spleen (β = 0.43, 95% CI 0.18–0.68, p < 0.001) and driveline entry site (β = 0.04, 95% CI 0.01–0.06, p = 0.001). Twenty-two (19%) patients suffered CVE after PET/CT. In a binary logistic regression analysis metabolic activity at the driveline entry site missed the level of significance as an influencing factor for CVE after adjusting for anticoagulation (OR = 1.16, 95% CI 1–1.33, p = 0.05). Metabolic activity of the subcutaneous driveline (OR = 1.13, 95% CI 1.02–1.24, p = 0.016) emerged as independent risk factor for mortality. Molecular imaging revealed systemic inflammatory interplay between thoracic aorta, hematopoietic organs, and infected device components in LVAD patients, the latter predicting CVE and mortality.
引用
收藏
相关论文
共 50 条
  • [31] Survival and Driveline Infection Rates in Patients on Chronic Immunosuppressive Therapy Who Undergo Left Ventricular Assist Device Implantation
    Spratt, J. R.
    Roy, S.
    Plack, D.
    John, R.
    Liao, K.
    Cogswell, R. J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S265 - S265
  • [32] Prevalence Of Cerebrovascular Events In Patients With Left Ventricular Assist Device - Continuous Flow And Pulsatile Flow Devices Compared
    Yoshioka, Daisuke
    Toda, Koichi
    Yoshikawa, Yasushi
    Sakaguchi, Manabu
    Okazaki, Shuhei
    Miyagawa, Shigeru
    Nishi, Hiroyuki
    Fukushima, Satsuki
    Saito, Tetsuya
    Sawa, Yoshiki
    STROKE, 2013, 44 (02)
  • [33] Pseudomonas aeruginosa left ventricular assist device (LVAD) driveline infection acquired from the bathroom at home
    Dix, Laura M. L.
    de Goeij, Inge
    Manintveld, Olivier C.
    Severin, Juliette A.
    Verkaik, Nelianne J.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2022, 50 (12) : 1392 - 1394
  • [34] Prevention of Percutaneous Driveline Infection After Left Ventricular Assist Device Implantation: Prophylactic Antibiotics Are Not Necessary
    Stulak, John M.
    Maltais, Simon
    Cowger, Jennifer
    Joyce, Lyle D.
    Daly, Richard C.
    Park, Soon J.
    Aaronson, Keith D.
    Pagani, Francis D.
    ASAIO JOURNAL, 2013, 59 (06) : 570 - 574
  • [35] The Limitation of Body Mass Index As a Predictor for Driveline Infection After Left Ventricular Assist Device Implantation
    Nitta, Daisuke
    Imamura, Teruhiko
    ASAIO JOURNAL, 2020, 66 (03) : E55 - E55
  • [36] Metabolic volume performs better than SUVmax in the detection of left ventricular assist device driveline infection
    Nemanja Avramovic
    Angelo Maria Dell’Aquila
    Matthias Weckesser
    Danka Milankovic
    Alexis Vrachimis
    Jürgen R. Sindermann
    Christian Wenning
    European Journal of Nuclear Medicine and Molecular Imaging, 2017, 44 : 1870 - 1877
  • [37] Metabolic volume performs better than SUVmax in the detection of left ventricular assist device driveline infection
    Avramovic, Nemanja
    Dell'Aquila, Angelo Maria
    Weckesser, Matthias
    Milankovic, Danka
    Vrachimis, Alexis
    Sindermann, Juergen R.
    Wenning, Christian
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 (11) : 1870 - 1877
  • [38] Driveline Infections and Sepsis in Patients Receiving the HVAD System as a Left-Ventricular Assist Device
    John, R.
    Aaronson, K. D.
    Pae, W. E.
    Acker, M. A.
    Hathaway, D. R.
    Najarian, K.
    Slaughter, M. S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S83 - S83
  • [39] Mortality And Morbidity Burden Of Covid-19 Infection In Left Ventricular Assist Device Patients
    Bhattal, Gurjaspreet K.
    Alom, Modar
    Banwait, Jasjit Kaur
    Kabra, Nitin
    Rawitscher, David
    Guerrero-Miranda, Cesar
    Alam, Amit
    Carey, Sandra
    George, Timothy
    Afzal, Aasim
    JOURNAL OF CARDIAC FAILURE, 2023, 29 (04) : 624 - 624
  • [40] Prospective analysis of bleeding events in left ventricular assist device patients
    Sherazi, Saadia
    Kouides, Peter
    Francis, Charles
    Lowenstein, Charles Julian
    Refaai, Majed
    Conley, Grace
    Johnson, Brent Alan
    Muchnik, Eugene
    Lien, Susan
    Massey, Howard Todd
    Alexis, Jeffrey Dean
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2018, 41 (05): : 269 - 276