Voltammetric determination of the antimalarial drug chloroquine using a glassy carbon electrode modified with reduced graphene oxide on WS2 quantum dots

被引:0
|
作者
Monika Srivastava
Preeti Tiwari
Vineet Kumar Mall
S. K. Srivastava
Rajiv Prakash
机构
[1] Banaras Hindu University,School of Materials Science and Technology, Indian Institute of Technology
[2] Banaras Hindu University,Department of Physics, Institute of Science
来源
Microchimica Acta | 2019年 / 186卷
关键词
Chloroquine phosphate; Anti-malarial drug; Reduced graphene oxide; WS; quantum dots; Synergistic effect;
D O I
暂无
中图分类号
学科分类号
摘要
A voltammetric method is described for the determination of chloroquine (CQ) and validated simultaneously by two techniques and in three different conditions. The WS2 quantum dots (WS2 QDs) were synthesized by a hydrothermal method and then placed on reduced graphene oxide (rGO) sheets. The resulting composite material was then deposited on a glassy carbon electrode (GCE) where it showed excellent electroactivity. The modified GCE responds to chloroquine at a typical potential maximum of 1.2 V (vs. AgCl/Ag). Techniques including cyclic voltammetry and differential pulse voltammetry were tested. Features of merit include (a) a wide linear response (in the 0.5 μM to 82 μM CQ concentration range), (b) an electrochemical sensitivity of 0.143–0.90 μA·μM−1·cm−2), and a 40–120 nM limit of detection (at S/N = 3). The sensor has excellent selectivity even in the presence of potentially interfering biological compounds. Responses were tested in phosphate buffer, human serum and pharmaceutical formulations, and no cross reactivity or matrix effects were found. In all the three cases, quite satisfactory recoveries were obtained.
引用
收藏
相关论文
共 50 条
  • [21] Voltammetric Determination of Cefuroxime Axetil in Pharmaceuticals Using Graphene Oxide Modified Glassy Carbon Electrode and Hanging Mercury Drop Electrode
    Kablan, Sevilay Erdogan
    Ozaltin, Nuran
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2019, 55 (04) : 305 - 313
  • [22] Voltammetric Determination of Cefuroxime Axetil in Pharmaceuticals Using Graphene Oxide Modified Glassy Carbon Electrode and Hanging Mercury Drop Electrode
    Sevilay Erdoğan Kablan
    Nuran Özaltın
    Russian Journal of Electrochemistry, 2019, 55 : 305 - 313
  • [23] Voltammetric Determination of Tenoxicam in Drug Formulation at Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Cabuk, Ahmet
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (05): : 4508 - 4519
  • [24] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Beigmoradi, Fariba
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2024, 60 (01) : 15 - 23
  • [25] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Surface Engineering and Applied Electrochemistry, 2024, 60 : 15 - 23
  • [26] Sensitive and selective stripping voltammetric determination of copper(II) using a glassy carbon electrode modified with amino-reduced graphene oxide and β-cyclodextrin
    Shan Huang
    Shuangyan Lu
    Chusheng Huang
    Jiarong Sheng
    Wei Su
    Lixia Zhang
    Qi Xiao
    Microchimica Acta, 2015, 182 : 2529 - 2539
  • [27] Sensitive and selective stripping voltammetric determination of copper(II) using a glassy carbon electrode modified with amino-reduced graphene oxide and β-cyclodextrin
    Huang, Shan
    Lu, Shuangyan
    Huang, Chusheng
    Sheng, Jiarong
    Su, Wei
    Zhang, Lixia
    Xiao, Qi
    MICROCHIMICA ACTA, 2015, 182 (15-16) : 2529 - 2539
  • [28] Voltammetric Determination of Folic Acid Using Adsorption of Methylene Blue onto Electrodeposited of Reduced Graphene Oxide Film Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Ouyang, Xiaoyan
    Ma, Weina
    Li, Lingzhi
    Zhang, Yanmin
    ELECTROANALYSIS, 2016, 28 (02) : 312 - 319
  • [29] Modifying a Glassy Carbon Electrode with Reduced Graphene Oxide for the Determination of Levofloxacin with a Glassy
    Ghanbari, Mohammad Hossein
    Rahimi-Nasrabadi, Mehdi
    Sobati, Hossein
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (02): : 189 - 200
  • [30] Voltammetric determination of palmitic acid by electrode modified with reduced graphene oxide
    Chin Boon Ching
    Jaafar Abdullah
    Nor Azah Yusof
    Journal of Food Science and Technology, 2022, 59 : 1053 - 1062