External fixators in the treatment of midshaft clavicle non-unions: A systematic review

被引:7
|
作者
Barlow T. [1 ,4 ]
Upadhyay P. [2 ]
Barlow D. [3 ]
机构
[1] Department of Trauma and Orthopaedics, University of Warwick, Coventry
[2] Department of Trauma and Orthopaedics, University Hospital of Coventry and Warwickshire, Coventry
[3] Department of Trauma and Orthopaedics, University Hospital of Stoke, Stoke-on-Trent
[4] Clinical Sciences Research Laboratories, University Hospitals of Coventry and Warwickshire
关键词
Clavicle; External fixators; Fracture fixation; Fracture healing;
D O I
10.1007/s00590-013-1173-6
中图分类号
学科分类号
摘要
Non- or mal-union of the clavicle is reported to occur in up to 15 % of conservatively treated fractures: the purpose of this systematic review is to examine the evidence for the use of external fixation in the treatment of clavicular non-union. We performed a search of MEDLINE and Embase, including all papers using external fixators for the treatment of clavicular non-union. Four papers satisfied our eligibility criteria: three case series and one case-control study. Level of evidence and quality assessment scoring were performed using published methods. Due to the heterogeneity of the study populations and interventions, no attempt at meta-analysis was made. External fixation in hypertrophic non-union of the clavicle, but not atrophic non-union, appears to be a reasonable treatment option. A pragmatic, multicentre, randomised controlled trial comparing external fixation and open reduction internal fixation in the treatment of hypertrophic non-union of the clavicle would be valuable. © 2013 Springer-Verlag France.
引用
收藏
页码:143 / 148
页数:5
相关论文
共 50 条
  • [21] Treatment of diaphyseal non-unions of the ulna and radius
    Kloen, Peter
    Wiggers, Jim K.
    Buijze, Geert A.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (12) : 1439 - 1445
  • [22] Outcome after surgical treatment of symptomatic delayed unions and nonunions of midshaft clavicle fractures
    Laudato, P.
    Djahangiri, A.
    Farron, A.
    SWISS MEDICAL WEEKLY, 2010, 140 (23-24) : 15S - 15S
  • [23] DELAYED UNIONS AND NON-UNIONS OF THE DISTAL PHALANX - A REVIEW OF 13 CASES
    VOCHE, P
    MERLE, M
    PILLOT, D
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1995, 81 (06): : 485 - 490
  • [24] Surgical fixation of midshaft clavicle fractures: A systematic review of biomechanical studies
    Hulsmans, Martijn H.
    Van Heijl, Mark
    Houwert, Roderick M.
    Burger, Bart J.
    Verleisdonk, Egbert Jan. M.
    Veeger, Dirk Jan
    van der Meijden, Olivier A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (04): : 753 - 765
  • [25] THE AO TUBULAR EXTERNAL FIXATOR IN THE TREATMENT OF OPEN FRACTURES AND INFECTED NON-UNIONS OF THE SHAFT OF THE FEMUR
    BARQUET, A
    SILVA, R
    MASSAFERRO, J
    DUBRA, A
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1988, 19 (06): : 415 - 420
  • [26] Autologous MSCs and osteoprogenitor cells for treatment of non-unions
    Peters, A.
    Schell, H.
    Lienau, J.
    Toben, D.
    Bach, B.
    Bail, H.
    Duda, G.
    Kaspar, K.
    CALCIFIED TISSUE INTERNATIONAL, 2008, 82 : S74 - S74
  • [27] Teriparatide in the treatment of non-unions: Scientific and clinical evidences
    Pietrogrande, Luca
    Raimondo, Emanuela
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 : S54 - S57
  • [28] Autologous MSCS and osteoprogenitor cells for treatment of non-unions
    Peters, A.
    Kaspar, K.
    Schell, H.
    Lienau, L.
    Toben, D.
    Bail, H. J.
    Duda, G. N.
    TISSUE ENGINEERING PART A, 2008, 14 (05) : 810 - 810
  • [29] RESULTS OF TREATMENT OF NON-UNIONS WITH ELECTRICAL-STIMULATION
    KHASIGIAN, HA
    ORTHOPEDICS, 1980, 3 (01) : 29 - 32
  • [30] A prospective comparison between external fixation and plates for treatment of midshaft nonunions of the clavicle
    Nowak, J
    Rahme, H
    Holgersson, M
    Lindsjö, U
    Larsson, S
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 2001, 90 (04) : 280 - 285