Stannum film electrode for square wave voltammetric determination of trace copper(II)

被引:0
|
作者
Yun Qing Tian
Hong Qun Luo
Nian Bing Li
机构
[1] Southwest University,Key Laboratory of Eco
关键词
Stannum film electrode; Copper(II); Anodic stripping voltammetry;
D O I
暂无
中图分类号
学科分类号
摘要
An anodic stripping voltammetric procedure for the determination of Cu(II) at an in situ-plated stannum film electrode (SnFE) was described. The results indicated that the SnFE had an attractive electroanalytical performance, with two distinct voltammetric stripping signals for copper and stannum, and showed the superior advantage for the determination of copper compared with the bismuth film electrode. Several experimental parameters were optimized. The SnFE exhibited highly linear behavior in the concentration range from 1.0 to 100.0 μg L−1 of Cu(II) (r = 0.994) with the detection limit of 0.61 μg L−1 (S/N = 3), and the relative standard deviation for a solution containing 40.0 μg L−1 Cu(II) was 2.2% (n = 8). The procedure has been successfully applied for the determination of Cu(II) in lake water sample.
引用
收藏
页码:529 / 533
页数:4
相关论文
共 50 条
  • [31] Square-wave voltammetric determination of paraquat at carbon paste electrode modified with hydroxyapatite
    El Mhanunedi, Moulay Abderrahim
    Bakasse, Mina
    Chtaini, Abdelilah
    ELECTROANALYSIS, 2007, 19 (16) : 1727 - 1733
  • [32] Voltammetric and Square-Wave Anodic Stripping Determination of Amlodipine Besylate on Gold Electrode
    Stoiljkovic, Z. Z.
    Ivic, M. L. Avramov
    Petrovic, S. D.
    Mijin, D. Z.
    Stevanovic, S. I.
    Lacnjevac, U. C.
    Marinkovic, A. D.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (03): : 2288 - 2303
  • [33] Electroanalytical study and square wave voltammetric techniques for the determination of β-blocker timolol at the mercury electrode
    Arranz, A
    Dolara, I
    de Betoño, SF
    Moreda, JM
    Cid, A
    Arranz, JF
    ANALYTICA CHIMICA ACTA, 1999, 389 (1-3) : 225 - 232
  • [34] Square-wave voltammetric determination of thallium using surface modified thick-film graphite electrode with Bi nanopowder
    Lee, Gyroung-Ja
    Lee, Hi Min
    Uhm, Young Rang
    Lee, Min Ku
    Rhee, Chang-Kyu
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (12) : 1920 - 1923
  • [35] Renewable Silver-Amalgam Film Electrode for Rapid Square-Wave Voltammetric Determination of Thiamethoxam Insecticide in Selected Samples
    Putek, Maria
    Guzsvany, Valeria
    Tasic, Bojan
    Papp, Zsigmond
    Zarebski, Jerzy
    Bobrowski, Andrzej
    ELECTROANALYSIS, 2012, 24 (12) : 2258 - 2266
  • [36] SQUARE-WAVE VOLTAMMETRIC DETERMINATION OF DAMINOZIDE
    IANNIELLO, RM
    ANALYTICA CHIMICA ACTA, 1987, 193 : 81 - 86
  • [37] Square-wave Voltammetric Determination of Ezetimibe
    Yola, Mehmet Lutfi
    Ozaltin, Nuran
    REVISTA DE CHIMIE, 2011, 62 (04): : 420 - 426
  • [38] Square wave voltammetric determination of trypsin activity
    Stoytcheva, Margarita
    Zlatev, Roumen
    Cosnier, Serge
    Arredondo, Michelle
    ELECTROCHIMICA ACTA, 2012, 76 : 43 - 47
  • [39] A nanocarbon paste electrode modified with nitrogen-doped graphene for square wave anodic stripping voltammetric determination of trace lead and cadmium
    Xinsheng Liu
    Zhaojun Li
    Runmei Ding
    Binbin Ren
    Yonghong Li
    Microchimica Acta, 2016, 183 : 709 - 714
  • [40] A nanocarbon paste electrode modified with nitrogen-doped graphene for square wave anodic stripping voltammetric determination of trace lead and cadmium
    Liu, Xinsheng
    Li, Zhaojun
    Ding, Runmei
    Ren, Binbin
    Li, Yonghong
    MICROCHIMICA ACTA, 2016, 183 (02) : 709 - 714