Background: Predictive indexes of weaning from mechanical ventilation are often inaccurate. Among the many indexes used in clinical practice, the rapid shallow breathing index is one of the most accurate. We evaluated a new weaning index consisting in the diaphragm thickening fraction (DTF) assessed by ultrasound. Methods: Forty-six patients were prospectively enrolled. All patients were ventilated in pressure support through a tracheostomy tube. Patients underwent a spontaneous breathing trial (SBT) when they met all the following criteria: FiO2 < 0.5, PEEP ≤5 cmH2O, PaO2/FiO2 > 200, respiratory rate <30 breaths per minute, absence of fever, alert and cooperative, and hemodynamic stability without vaso-active therapy support. During the trial, the right hemi-diaphragm was visualized in the zone of apposition using a 10-MHz linear ultrasound probe. The patient was then instructed to perform breathing to total lung capacity (TLC) and then exhaling to residual volume (RV). Diaphragm thickness was recorded at TLC and RV, and the DTF was calculated as percentage from the following formula: Thickness at end inspiration - Thickness at end expiration / Thickness at end expiration. Also, the rapid shallow breathing index (RSBI) was calculated. Weaning failure was defined as the inability to maintain spontaneous breathing for at least 48 h, without any form of ventilatory support. Results: A significant difference between diaphragm thickness at TLC and RV was observed both in patients who succeeded SBT and patients who failed. DTF was significantly different between patients who failed and patients who succeeded SBT. A cutoff value of a DTF >36% was associated with a successful SBT with a sensitivity of 0.82, a specificity of 0.88, a positive predictive value (PPV) of 0.92, and a negative predictive value (NPV) of 0.75. By comparison, RSBI <105 had a sensitivity of 0.93, a specificity of 0.88, a PPV of 0.93, and a NPV of 0.88 for determining SBT success. Conclusions: This study shows that in our cohort of patients, the assessment of DTF by diaphragm ultrasound may perform similarly to other weaning indexes. If validated by other studies, this method may be used in clinical practice. © 2014 Ferrari et al.; licensee Springer.
引用
收藏
页码:1 / 6
相关论文
共 50 条
  • [21] DISCONTINUATION OF MECHANICAL VENTILATION
    SPORN, PHS
    MORGANROTH, ML
    CLINICS IN CHEST MEDICINE, 1988, 9 (01) : 113 - 126
  • [22] Diaphragm ultrasound in weaning from mechanical ventilation: a last step to predict successful extubation?
    Di Costanzo, Domenica
    Mazza, Mariano
    Esquinas, Antonio
    ACUTE AND CRITICAL CARE, 2022, 37 (04) : 681 - 682
  • [23] Prediction of successful weaning from mechanical ventilation by continuous ultrasound monitoring of diaphragm excursion
    Demoule, Alexandre
    Virolle, Sara
    Mercat, Alain
    Bergum, Daniel
    Bureau, Come
    Mortaza, Satar
    EUROPEAN RESPIRATORY JOURNAL, 2021, 58
  • [24] Prediction of Successful Weaning from Mechanical Ventilation by Continuous Ultrasound Monitoring of Diaphragm Excursion
    Demoule, A.
    Virolle, S.
    Mercat, A.
    Bergum, D.
    Bureau, C.
    Mortaza, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)
  • [25] Mechanical ventilation and the diaphragm
    Nichols, DG
    CRITICAL CARE MEDICINE, 1998, 26 (07) : 1155 - 1157
  • [26] Validation of a ultrasound index predictive of failure of weaning from mechanical ventilation
    Binet, C.
    Neron, L.
    Rochart, N.
    Cousson, J.
    Floch, T.
    Charbit, B.
    Leon, A.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2014, 33 : A383 - A383
  • [27] Effect of Mode of Mechanical Ventilation and Sedation on Diaphragm Thickness Measured by Ultrasound
    Pearson, S. D.
    Lin, J.
    Stutz, M. R.
    Lecompte-Osorio, P.
    Wolfe, K. S.
    Pohlman, A.
    Hall, J. B.
    Patel, B. K.
    Kress, J. P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)
  • [28] Diaphragm function and weaning from mechanical ventilation: an ultrasound and phrenic nerve stimulation clinical study
    Dres, Martin
    Goligher, Ewan C.
    Dube, Bruno-Pierre
    Morawiec, Elise
    Dangers, Laurence
    Reuter, Danielle
    Mayaux, Julien
    Similowski, Thomas
    Demoule, Alexandre
    ANNALS OF INTENSIVE CARE, 2018, 8
  • [29] Diaphragm function and weaning from mechanical ventilation: an ultrasound and phrenic nerve stimulation clinical study
    Martin Dres
    Ewan C. Goligher
    Bruno-Pierre Dubé
    Elise Morawiec
    Laurence Dangers
    Danielle Reuter
    Julien Mayaux
    Thomas Similowski
    Alexandre Demoule
    Annals of Intensive Care, 8
  • [30] Diaphragmatic ultrasound: A new frontier in weaning from mechanical ventilation
    Kamal, Manoj
    Sengupta, Saikat
    INDIAN JOURNAL OF ANAESTHESIA, 2023, 67 (SUPPL 4) : S205 - S207