Selective recording of neuroelectric activity from the peripheral nerve

被引:0
|
作者
Janez Rozman
Bojan Zorko
Alenka Seliškar
Matjaž Bunc
机构
[1] ITIS d. o. o. Ljubljana,
[2] Centre for Implantable Technology and Sensors,undefined
[3] Lepi pot 11,undefined
[4] University of Ljubljana,undefined
[5] ,undefined
[6] Veterinary Faculty,undefined
[7] Gerbičeva 60,undefined
[8] ,undefined
[9] School of Medicine,undefined
[10] Institute of Pathophysiology,undefined
[11] Zaloška 4,undefined
[12] 1000 Ljubljana,undefined
[13] Republic of Slovenia,undefined
关键词
Key words spiral nerve cuff; neuroelectric activity; sciatic nerve; skeletal muscle;
D O I
暂无
中图分类号
学科分类号
摘要
Electroneurograms (ENGs) from superficial regions of the sciatic nerve of a dog, innervating the tibialis anterior (TA) and gastrocnemius muscles (GM), arising mainly from muscle spindles and Golgi tendon organs were recorded selectively with an implanted 33-electrode spiral cuff (cuff). Relative positions of superficial regions within the cuff were defined by delivering stimulating pulses on groups of three electrodes (GTEs) within the cuff which were in contact with them. It was found that GTEs eliciting maximum contractions of muscles were GTE No. 3 for the TA muscle and GTE No. 8 for the GM muscle. In the first experiment the implanted leg was mounted into a special electronic brace. Extending forces were applied to the ankle rotating it by up to ±37° according to the neutral position, thus eliciting torques in the TA muscle of up to 1.2Nm. Channel 1 of the 4-channel preamplifier was connected to GTE No. 8, channel 2 to GTE No. 2, channel 3 to GTE No. 11 and channel 4 to GTE No. 5. Results show that only ENG recorded with GTE No. 8, being close to the region innervating the TA muscle, correspond to the mechanical load. In the second experiment the calcanean tendon (CT) of an implanted leg was dissected. The proximal end of the CT was connected to a force transducer and repetitive pull forces (about 12N) were applied to the CT. Channel 1 of the preamplifier was connected to GTE No. 5, channel 2 to GTE No. 1, channel 3 to the GTE No. 11 and channel 4 to GTE No. 8. Results show that only ENG recorded with GTE No. 5, being close to the region innervating the GM muscle, correspond to the mechanical load applied on CT.
引用
收藏
页码:R157 / R159
相关论文
共 50 条
  • [21] Directionally-Sensitive Peripheral Nerve Recording: Bipolar Nerve Cuff Design
    Sabetian, Parisa
    Popovic, Milos R.
    Yoo, Paul B.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 6178 - 6181
  • [22] Selective peripheral nerve recordings from nerve cuff electrodes using convolutional neural networks
    Koh, Ryan G. L.
    Balas, Michael
    Nachman, Adrian, I
    Zariffa, Jose
    JOURNAL OF NEURAL ENGINEERING, 2020, 17 (01)
  • [23] Mesotrode chronic simultaneous mesoscale cortical imaging and subcortical or peripheral nerve spiking activity recording in mice
    Xiao, Dongsheng
    Yan, Yuhao
    Murphy, Timothy H.
    ELIFE, 2023, 12
  • [24] Selective fascicular recording of the hypoglossal nerve using a multicontact nerve cuff electrode
    Yoo, PB
    Durand, DM
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 2172 - 2175
  • [25] METHOD OF RECORDING NERVE TERMINAL ACTIVITY IN FROG
    DRETCHEN, KL
    SOKOLL, MD
    LONG, JP
    JOURNAL OF APPLIED PHYSIOLOGY, 1973, 34 (05) : 736 - 739
  • [26] Improving suction technology for nerve activity recording
    Domacena, Justin
    Ruan, Joyce
    Ye, Hui
    JOURNAL OF NEUROSCIENCE METHODS, 2022, 365
  • [27] TECHNIQUE FOR CHRONIC PERIPHERAL-NERVE RECORDING IN CONSCIOUS ANIMALS
    ORLEA, CJ
    ANDRESEN, MC
    KUNZE, DL
    FEDERATION PROCEEDINGS, 1982, 41 (05) : 1522 - 1522
  • [28] REGENERATION MICROELECTRODE ARRAY FOR PERIPHERAL-NERVE RECORDING AND STIMULATION
    KOVACS, GTA
    STORMENT, CW
    ROSEN, JM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (09) : 893 - 902
  • [29] Peripheral Nerve Signal Recording and Processing for Artificial Limb Control
    Wodlinger, B.
    Durand, D. M.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 6206 - 6209
  • [30] Peripheral Neural Activity Recording and Stimulation System
    Loi, Daniela
    Carboni, Caterina
    Angius, Gianmarco
    Angotzi, Gian Nicola
    Barbaro, Massimo
    Raffo, Luigi
    Raspopovic, Stanisa
    Navarro, Xavier
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2011, 5 (04) : 368 - 379