Soft X-ray Imaging using a Neon Filled Plasma Focus X-ray Source

被引:0
|
作者
R. S. Rawat
T. Zhang
G. J. Lim
W. H. Tan
S. J. Ng
A. Patran
S. M. Hassan
S. V. Springham
T. L. Tan
M. Zakaullah
P. Lee
S. Lee
机构
[1] National Institute of Education,Natural Sciences and Science Education
[2] Quaid-I-Azam University,Department of Physics
[3] International Center for Dense Magnetized Plasma,undefined
来源
Journal of Fusion Energy | 2004年 / 23卷
关键词
Plasma focus; soft X-rays; insects’ imaging; CCD camera;
D O I
暂无
中图分类号
学科分类号
摘要
A 3 kJ Mather-type UNU/ICTP plasma focus device with neon filling is used, for the first time, as a soft X-ray source for imaging of thin biological samples including insects. A charge-coupled-device (CCD) based pinhole projection system, placed in a differentially pumped chamber, is used for radiography using neon soft X-rays. The image brightness, contrast and resolution have been optimized by varying soft X-ray yield, pinhole size, camera chamber length and X-ray filters. The system can simply be modified for table-top soft X-ray microscopy of thin biological samples.
引用
收藏
页码:49 / 53
页数:4
相关论文
共 50 条
  • [21] PLASMA-FOCUS X-RAY SOURCE FOR LITHOGRAPHY
    KATO, Y
    OCHIAI, I
    WATANABE, Y
    MURAYAMA, S
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1988, 6 (01): : 195 - 198
  • [22] Plasma focus as a possible x-ray source for radiography
    Hussain, S
    Shafiq, M
    Ahmad, R
    Waheed, A
    Zakaullah, M
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2005, 14 (01): : 61 - 69
  • [23] Effect of insulator sleeve length on soft x-ray emission from a neon-filled plasma focus device
    Rawat, RS
    Zhang, T
    Phua, CBL
    Then, JXY
    Chandra, KA
    Lin, X
    Patran, A
    Lee, P
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2004, 13 (04): : 569 - 575
  • [24] X-ray microscopy and imaging of Caenorhabditis elegans nematode using a laser plasma pulsed x-ray source
    Poletti, G
    Orsini, F
    Ullschmied, J
    Skala, J
    Kralikova, B
    Pfeifer, M
    Kadlec, C
    Mocek, T
    Präg, A
    Cotelli, F
    Lamia, CL
    Batani, D
    Bernardinello, A
    Desai, T
    Zullini, A
    LASER-GENERATED AND OTHER LABORATORY X-RAY AND EUV SOURCES, OPTICS, AND APPLICATIONS, 2003, 5196 : 375 - 382
  • [25] Design of a stereoscopic X-ray imaging system using a single X-ray source
    Evans, JPO
    Robinson, M
    NDT & E INTERNATIONAL, 2000, 33 (05) : 325 - 332
  • [26] Plasma X-ray source
    David Pile
    Nature Photonics, 2015, 9 (10) : 631 - 631
  • [27] Laboratory X-ray microscopy with a nano-focus X-ray source
    Nachtrab, Frank
    Ebensperger, Thomas
    Schummer, Bernhard
    Sukowski, Frank
    Hanke, Randolf
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [28] Phase contrast imaging using a micro focus x-ray source
    Zhou, Wei
    Majidi, Keivan
    Brankov, Jovan G.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS IX, 2014, 9207
  • [29] Parametric X-ray radiation as a novel source for X-ray imaging
    Takahashi, Yumiko
    Hayakawa, Yasushi
    Kuwada, Takao
    Tanaka, Toshinari
    Sakae, Toshiro
    Nakao, Keisuke
    Nogami, Kyoko
    Imagaki, Manabu
    Hayakawa, Ken
    Sato, Isamu
    X-RAY SPECTROMETRY, 2012, 41 (04) : 210 - 215
  • [30] Spectroscopic study of soft X-ray sources generated in a plasma focus with neon gas puffing
    Yanagidaira, T
    Yamamoto, T
    Hirano, K
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1999, 68 (03) : 839 - 843