Differential pulse polarographic determination of Co(II) using moxifloxacine

被引:0
|
作者
R. İnam
H. Mercan
E. Yılmaz
B. Uslu
机构
[1] Gazi University,Faculty of Arts and Sciences, Department of Chemistry
[2] Ankara University,Faculty of Pharmacy, Department of Analytical Chemistry
来源
关键词
differential pulse polarography; Co(II) determination; moxifloxacin;
D O I
暂无
中图分类号
学科分类号
摘要
The polarographic reduction of Co(II) in the presence of moxifloxacin (1-cyclopropyl-7-[(S,S)-2.8-diazabicyclo[4.3.0]non-8-yl]-6-fluoro-8-methoxy-1.4-dihydro-4-oxo-3-quinolinecarboxylic acid) gives rise to an additional adsorption peak corresponding to the reduction of Co(II)-moxifloxacin complex on the mercury drop electrode at −1.17 V. This new peak is applicable to Co(II) determination with the linearity proportional to the Co(II) concentration in the range of 4.93 × 10−7−6.90 × 10−5 M and can be attributed to an adsorption-controlled process with an irreversible reduction. Without using moxifloxacin, the polarographic determination of 2.50 × 10−6 M Co(II) is impossible under the given conditions due to very poor sensitivity at −1.38 V. The proposed method showed good precision and accuracy with a relative standard deviation of 3.01% and relative error of +6.40% for the determination of 2.50 × 10−6 M Co(II) next to 5.0 × 10−6 M of Zn(II), Ni(II), and Cd(II). The accuracy of the method was also checked by the determination of Co(II) spiked with tap water and certified sea water, and the percentage recoveries were 97.5 and 96.7%, respectively (n = 4 at 95% confidence interval).
引用
收藏
页码:592 / 598
页数:6
相关论文
共 50 条
  • [21] Differential pulse polarographic trace level determination of selenium
    Sharma, P
    Vyas, S
    Sanganeria, S
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1998, 37 (04): : 371 - 373
  • [22] Differential pulse polarographic determination of pravastatin sodium in tablets
    Coskun, NY
    Aycan, S
    Sungur, S
    PHARMAZIE, 1997, 52 (06): : 485 - 486
  • [23] Determination of zinc and manganese by differential pulse polarographic technique
    Kumar, A
    BULLETIN OF ELECTROCHEMISTRY, 1997, 13 (05): : 209 - 212
  • [24] DIFFERENTIAL-PULSE POLAROGRAPHIC-DETERMINATION OF NITRITE
    SULAIMAN, ST
    AKRAWI, BA
    ANALYST, 1984, 109 (12) : 1545 - 1547
  • [25] Differential pulse polarographic trace level determination of iodate
    Sharma, P.
    Songara, S.
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2007, 14 (04) : 427 - 429
  • [26] Differential pulse polarographic determination of procymidone in formulations and wine
    Sreedhar, NY
    Babu, TR
    Samatha, K
    Sujatha, D
    Thriveni, T
    JOURNAL OF AOAC INTERNATIONAL, 2002, 85 (03) : 731 - 735
  • [27] Differential pulse polarographic determination of uranium in bituminous coal
    Nogami, EM
    Dalmeida-Oliveira, GM
    Nozaki, J
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1997, 68 (01) : 25 - 31
  • [28] DIFFERENTIAL PULSE POLAROGRAPHIC-DETERMINATION OF SOME BARBITURATES
    TEMIZER, A
    SOLAK, AO
    ARCHIV DER PHARMAZIE, 1986, 319 (02) : 149 - 154
  • [29] DIFFERENTIAL PULSE POLAROGRAPHIC-DETERMINATION OF ORGANOCHLORINE PESTICIDES
    FAYYAD, M
    ALAWI, M
    ISSA, I
    ANALYTICAL LETTERS, 1989, 22 (08) : 1939 - 1959
  • [30] DIFFERENTIAL-PULSE POLAROGRAPHIC-DETERMINATION OF NIMODIPINE
    REDDY, YVR
    REDDY, SJ
    BULLETIN OF ELECTROCHEMISTRY, 1994, 10 (9-10): : 428 - 429