Validation of the Mobius system for patient-specific quality assurance using introduced intentional errors

被引:0
|
作者
Ivy Win Long Au
Laura Ciurlionis
Neil Campbell
Daniel Goodwin
机构
[1] Auckland City Hospital,
关键词
Patient specific QA; Treatment verification; VMAT; Gamma analysis; Introduced errors; Mobius; ArcCHECK; 3DVH;
D O I
暂无
中图分类号
学科分类号
摘要
Mobius3D and MobiusFX are model-based verification tools for treatment plan dose calculation and treatment delivery. The software facilitates patient-specific quality assurance by extracting data from linear accelerator treatment log files and performing a 3D dose calculation on the original patient CT dataset using an independent collapsed cone algorithm. In this study, we evaluate the ability of the Mobius system to detect linear accelerator-related errors compared with existing measurement-based systems, namely the ArcCHECK® and 3DVH® systems. Three original treatment plans and 47 plans with introduced delivery errors, for a total of 50 plan deliveries, were investigated. The results from this study demonstrated comparable gamma passing rates and error detectability between the Mobius and ArcCHECK® systems while the 3DVH system generally exhibited a lower sensitivity. This work also demonstrated the ability of the Mobius system to detect delivery errors of down to 2° collimator rotation, 1 mm MLC bank offset and 10 mm collimator jaw offset.
引用
收藏
页码:181 / 189
页数:8
相关论文
共 50 条
  • [31] Patient-specific quality assurance for IMRT delivery: A multicentre study
    Hizam, Diyana Afrina
    Jong, Wei Loong
    Zin, Hafiz Mohd
    Ng, Kwan Hoong
    Ung, Ngie Min
    RADIATION PHYSICS AND CHEMISTRY, 2023, 209
  • [32] Evaluation of Patient-Specific Quality Assurance Based On Different Methods
    Lin, X.
    Sun, T.
    Liu, X.
    MEDICAL PHYSICS, 2018, 45 (06) : E211 - E211
  • [33] Commissioning of Mobius3D/FX for patient-specific quality assurance: The CUIMC-NewYork Presbyterian Hospital experience
    Li, Fiona
    Price, Michael
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (02):
  • [34] Volumetric Patient-Specific Quality Assurance for VMAT Treatment Delivery Using the Dynalog Files
    Schreibmann, E.
    Dhabaan, A.
    Elder, E.
    Fox, T.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [35] Virtual VMAT QA prospective validation: towards measurement-free patient-specific quality assurance
    Wall, P.
    Hirata, E.
    Morin, O.
    Valdes, G.
    Witztum, A.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S545 - S547
  • [36] Sensitivity of Three Patient-Specific Quality Assurance Systems to MLC Aperture Errors With Volumetric Modulated Arc Therapy
    Hu, Jinyou
    Gu, Shaoxian
    Wang, Ningyu
    Cui, Fengjie
    Zhang, Shengyuan
    Yin, Chuou
    Cai, Yunzhu
    Gou, Chengjun
    Zou, Lian
    Wu, Zhangwen
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
  • [37] Development and Validation of a Machine Learning Predictive Model of IMRT Patient-Specific Quality Assurance Approval Using Gamma-Radiomics
    Yaly, C.
    Lizar, J.
    Santos, P.
    Colello Bruno, A.
    Viani, G.
    Pavoni, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E601 - E601
  • [38] Validation of 3D Patient-Specific Quality-Assurance Software (COMPASS) Using AAPM TG-119
    Sharma, S.
    Subramani, V.
    Kumar, P.
    Bhaskar, S.
    Pathy, S.
    Thulkar, S.
    Gopishankar, N.
    Chander, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2876 - 2876
  • [39] Usefulness of a new online patient-specific quality assurance system for respiratory-gated radiotherapy
    Kurosawa, Tomoyuki
    Tachibana, Hidenobu
    Moriya, Shunsuke
    Miyakawa, Shin
    Nishio, Teiji
    Sato, Masanori
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 43 : 63 - 72
  • [40] Feasibility study of structural similarity index for patient-specific quality assurance
    Lee, Jae Choon
    Park, Hyeong Wook
    Kang, Young Nam
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (03):