Validation of the Mobius system for patient-specific quality assurance using introduced intentional errors

被引:0
|
作者
Ivy Win Long Au
Laura Ciurlionis
Neil Campbell
Daniel Goodwin
机构
[1] Auckland City Hospital,
关键词
Patient specific QA; Treatment verification; VMAT; Gamma analysis; Introduced errors; Mobius; ArcCHECK; 3DVH;
D O I
暂无
中图分类号
学科分类号
摘要
Mobius3D and MobiusFX are model-based verification tools for treatment plan dose calculation and treatment delivery. The software facilitates patient-specific quality assurance by extracting data from linear accelerator treatment log files and performing a 3D dose calculation on the original patient CT dataset using an independent collapsed cone algorithm. In this study, we evaluate the ability of the Mobius system to detect linear accelerator-related errors compared with existing measurement-based systems, namely the ArcCHECK® and 3DVH® systems. Three original treatment plans and 47 plans with introduced delivery errors, for a total of 50 plan deliveries, were investigated. The results from this study demonstrated comparable gamma passing rates and error detectability between the Mobius and ArcCHECK® systems while the 3DVH system generally exhibited a lower sensitivity. This work also demonstrated the ability of the Mobius system to detect delivery errors of down to 2° collimator rotation, 1 mm MLC bank offset and 10 mm collimator jaw offset.
引用
收藏
页码:181 / 189
页数:8
相关论文
共 50 条
  • [1] Validation of the Mobius system for patient-specific quality assurance using introduced intentional errors
    Au, Ivy Win Long
    Ciurlionis, Laura
    Campbell, Neil
    Goodwin, Daniel
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) : 181 - 189
  • [2] Validation of Model Based Patient Specific Quality Assurance (QA) Using Introduced Intentional Errors
    Au, I. W. L.
    Ciurlionis, L.
    Campbell, N.
    Talbot, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E623 - E623
  • [3] Using an EPID for patient-specific VMAT quality assurance
    Bakhtiari, M.
    Kumaraswamy, L.
    Bailey, D. W.
    de Boer, S.
    Malhotra, H. K.
    Podgorsak, M. B.
    MEDICAL PHYSICS, 2011, 38 (03) : 1366 - 1373
  • [4] Quantitative Evaluation of Patient-Specific Quality Assurance Using Online Dosimetry System
    Jung, Jae-Yong
    Shin, Young-Ju
    Sohn, Seung-Chang
    Min, Jung-Whan
    Kim, Yon-Lae
    Kim, Dong-Su
    Choe, Bo-Young
    Suh, Tae-Suk
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 72 (02) : 312 - 319
  • [5] Quantitative evaluation of patient-specific quality assurance using online dosimetry system
    Jae-Yong Jung
    Young-Ju Shin
    Seung-Chang Sohn
    Jung-Whan Min
    Yon-Lae Kim
    Dong-Su Kim
    Bo-Young Choe
    Tae-Suk Suh
    Journal of the Korean Physical Society, 2018, 72 : 312 - 319
  • [6] Commissioning and Validation of Patient-Specific Quality Assurance On An MR-Linac
    Du, D.
    Kim, J.
    Glide-Hurst, C.
    Doemer, A.
    Wen, N.
    Movsas, B.
    Dragovic, J.
    Chetty, I.
    MEDICAL PHYSICS, 2018, 45 (06) : E143 - E143
  • [7] Tornotherapy patient-specific quality assurance
    Chaudhari, S.
    Goddu, S.
    Mutic, S.
    Grigsby, J.
    Low, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2498 - 2499
  • [8] Validation of COMPASS for Pre-Treatment Patient-Specific Quality Assurance
    Sharma, S.
    Sairem, M.
    Binjola, A.
    Subramani, V.
    Chander, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E876 - E877
  • [9] Validation of Dolphin dosimetry in three dimensional patient-specific quality assurance programme
    Puzhakkal, Niyas
    Kochunny, Abdullah Kallilzuzhiyil
    Makuny, Dinesh
    Krishnan, Arun M. P.
    Poyil, Ranjith C.
    Raveendran, Vysalzh
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (05) : 481 - 490
  • [10] Patient-specific quality assurance for intracranial cases in robotic radiosurgery system
    Koksal, Canan
    Akbas, Ugur
    Kesen, Nazmiye Donmez
    Okutan, Murat
    Bilge, Hatice
    Kemikler, Gonul
    JOURNAL OF BUON, 2018, 23 (01): : 179 - 184