Efficiency calibration of an on-line detection device for fuel rod failure in a PWR

被引:0
|
作者
Guoxiu Qin
Yujuan Liu
Youning Xu
Weizhe Li
Fan Li
Hexi Wu
机构
[1] Shenyang Institute of Engineering,
[2] East China University of Technology,undefined
关键词
Efficiency calibration; On-line detection device; Calibration system; True coincidence summing correction;
D O I
暂无
中图分类号
学科分类号
摘要
This paper describes a method of calibrating the efficiency of an on-line detection device for fuel rod failure in a pressurized water reactor. 214Am, 137Cs, 60Co and 24Na were selected to produce 4 sets of liquid calibration sources, and a calibration system that could simulate the on-site measurement of the on-line detection device was established. Efficiency calibration was performed against γ-ray lines, which could be identified by a LaBr3(Ce) detector. After a true coincidence summing correction, an efficiency curve of the on-line detection device for fuel rod failure was obtained, with a calibration uncertainty of 3.5%.
引用
收藏
页码:2067 / 2072
页数:5
相关论文
共 50 条
  • [31] Use of Unfold PCA for on-line plant stress monitoring and sensor failure detection
    Villez, Kris
    Steppe, Kathy
    De Pauw, Dirk J. W.
    BIOSYSTEMS ENGINEERING, 2009, 103 (01) : 23 - 34
  • [32] On-line detection of toxic components using a microbial fuel cell-based biosensor
    Stein, Nienke Elisabeth
    Hamelers, Hubertus M. V.
    van Straten, Gerrit
    Keesman, Karel J.
    JOURNAL OF PROCESS CONTROL, 2012, 22 (09) : 1755 - 1761
  • [33] An Improved Method for PWR Fuel Failure Detection Using Cascade-forward Neural Network With Decision Tree
    Dong, Bing
    Yang, Kang
    Zhang, Wei
    Yin, Junlian
    Wang, Dezhong
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [34] IVO, a device for In situ Volatilization and On-line detection of products from heavy ion reactions
    Düllmann, CE
    Eichler, B
    Eichler, R
    Gäggeler, HW
    Jost, DT
    Piguet, D
    Türler, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 479 (2-3): : 631 - 639
  • [35] On-line fuel-efficiency optimization of Diesel engines using constrained multivariable extremum-seeking
    van der Weijst, Robert
    van Keulen, Thijs
    Willems, Frank
    2018 EUROPEAN CONTROL CONFERENCE (ECC), 2018, : 213 - 218
  • [36] On-line Failure Detection and Identification (FDI) and Adaptive Reconfigurable Control (ARC) in aerospace applications
    Boskovic, JD
    Li, SM
    Mehra, RK
    PROCEEDINGS OF THE 2001 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2001, : 2625 - 2626
  • [37] On-line Detection of Load Release Failure and Controller Reconfiguration for a Post-boost Vehicle
    Li Xiaoyun
    Hang Canghua
    Duan Guangren
    Proceedings of the 27th Chinese Control Conference, Vol 2, 2008, : 323 - 327
  • [38] On-line model-based fault detection and isolation for PEM fuel cell stack systems
    Rosich, A.
    Sarrate, R.
    Nejjari, F.
    APPLIED MATHEMATICAL MODELLING, 2014, 38 (11-12) : 2744 - 2757
  • [39] On-Line Detection of Microbial Contaminations in Animal Cell Reactor Cultures Using an Electronic Nose Device
    Karl Kreij
    Carl-Fredrik Mandenius
    João J. Clemente
    António Eduardo Cunha
    Sandra M. S. Monteiro
    Manuel J. T. Carrondo
    Friedemann Hesse
    Maria Milagros Bassani de los Molinas
    Roland Wagner
    Otto-Wilhelm Merten
    Cécile Gény- Fiamma
    Wolfgang Leger
    Herbert Wiesinger-Mayr
    Dethard Müller
    Hermann Katinger
    Per Mårtensson
    Thomas Bachinger
    Jan Mitrovics
    Cytotechnology, 2005, 48 : 41 - 58
  • [40] On-line detection of microbial contaminations in animal cell reactor cultures using an electronic nose device
    Kreij, K
    Mandenius, CF
    Clemente, JJ
    Cunha, AE
    Monteiro, SMS
    Carrondo, MJT
    Hesse, F
    Molinas, MDMB
    Wagner, R
    Merten, OW
    Gény-Katinger, C
    Mårtensson, P
    Bachinger, T
    Mitrovics, J
    CYTOTECHNOLOGY, 2005, 48 (1-3) : 41 - 58