Noise reduction in optically pumped magnetometer assemblies

被引:0
|
作者
V. Schultze
R. IJsselsteijn
H.-G. Meyer
机构
[1] Institute of Photonic Technology (IPHT),
来源
Applied Physics B | 2010年 / 100卷
关键词
Noise Reduction; Shot Noise; Larmor Frequency; Photo Current; Coherent Population Trapping;
D O I
暂无
中图分类号
学科分类号
摘要
In most magnetic field measurement configurations the resolution of optically pumped magnetometers is limited by the shot noise of the pump light. However, in practice this noise limit is overwhelmed by other sources. One of them is the conversion of the pump laser’s frequency modulation (FM) noise to amplitude modulation (AM) noise due to the absorption in the magnetometer’s alkali vapour cell. This extra noise can be nearly completely cancelled by the illumination of an additional cell with the same laser light and the subtraction of its photo current from that of the measurement cell. The correlation of the photo signals of different cells is just slightly decreased by the applied measurement and rf fields B0 and B1, respectively. As a result, in real magnetic field measurements using the photo-current subtraction, a noise-limited magnetic field resolution of just twice the shot-noise limit can be achieved. This is experimentally shown for the most thrifty setup with two cells; one time using the second cell just for the photo-current subtraction, the other time also serving for magnetic field measurements, forming a gradiometer with the first cell. Yet, the photo-current subtraction method is most appealing for magnetometer arrays, where the photo signal of just one additional vapour cell can be used for the noise reduction of the complete array.
引用
收藏
页码:717 / 724
页数:7
相关论文
共 50 条
  • [21] A plateau in the sensitivity of a compact optically pumped atomic magnetometer
    Mizutani, Natsuhiko
    Okano, Kazuhisa
    Ban, Kazuhiro
    Ichihara, Sunao
    Terao, Akira
    Kobayashi, Tetsuo
    AIP ADVANCES, 2014, 4 (05):
  • [22] Experimental demonstration of the sensitivity of an optically pumped quantum magnetometer
    Alexandrov, EB
    Balabas, MV
    Vershovski, AK
    Pazgalev, AS
    TECHNICAL PHYSICS, 2004, 49 (06) : 779 - 783
  • [23] Adaptive multipole models of optically pumped magnetometer data
    Tierney, Tim M.
    Seedat, Zelekha
    St Pier, Kelly
    Mellor, Stephanie
    Barnes, Gareth R.
    HUMAN BRAIN MAPPING, 2024, 45 (04)
  • [24] Digital-locking optically pumped cesium magnetometer
    Shi, Rongye
    Liu, Chang
    Zhou, Sheng
    Wang, Yanhui
    2014 EUROPEAN FREQUENCY AND TIME FORUM (EFTF), 2014, : 144 - 146
  • [25] Studies on Noise Reduction of Optically Pumped Magnetometers by Digital Signal Processing
    Nambu, Kouta
    Ito, Yosuke
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2025, 108 (01)
  • [26] Studies on Noise Reduction of Optically Pumped Magnetometers by Digital Signal Processing
    Nambu, Kouta
    Ito, Yosuke
    IEEJ Transactions on Fundamentals and Materials, 2024, 144 (08) : 331 - 336
  • [27] System and approach to detecting of gastric slow wave and environmental noise suppression based on optically pumped magnetometer
    Liang, Shuang
    Gao, Kexin
    He, Junhuai
    Jia, Yikang
    Jiao, Hongchen
    Feng, Lishuang
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2024, 44 (01) : 1 - 8
  • [28] Light-noise suppression method for the single-beam optically-pumped magnetometer arrays
    Suo, Yuchen
    Song, Xinda
    Wu, Zhendong
    Yuan, Ziqi
    Jia, Le
    Long, Tengyue
    OPTICS EXPRESS, 2023, 31 (13) : 21280 - 21295
  • [29] Optimization of Signal Space Separation for Optically Pumped Magnetometer in Magnetoencephalography
    Wang, Ruonan
    Wu, Huanqi
    Liang, Xiaoyu
    Cao, Fuzhi
    Xiang, Min
    Gao, Yang
    Ning, Xiaolin
    BRAIN TOPOGRAPHY, 2023, 36 (03) : 350 - 370
  • [30] Optically pumped rubidium atomic magnetometer with elliptically polarized light
    Ding, Zhichao
    Yuan, Jie
    Wang, Zhiguo
    Lu, Guangfeng
    Luo, Hui
    OPTIK, 2016, 127 (13): : 5270 - 5273