Background: Cochlear implant surgeries are performed by different surgical routes, Round window (RW), Extended round window (Ext RW) and Cochleostomy (C). Optimum intracochlear electrode placement is important to achieve a successful outcome. Intra-operative electrophysiological testing (Impedance and ECAP) is crucial to assess the device function and appropriate electrode placement. The variability of portal of electrode insertion might affect the neural response and its characteristics. Objective: To compare the intraoperative electrophysiological measurements (Impedance and ECAP) for possible differences on auditory nerve stimulation across the three electrode insertion routes. Materials and Methods: This is a retrospective data analysis of 47 cochlear implant recipients at a tertiary care centre in Central India over a period of 4 years. They were broadly divided into two groups depending on the electrode design as full banded and half banded. Intraoperative impedances were recorded for different modes of stimulation and ECAP measured at E5, E10, E15, E20 electrodes in both the groups across the three insertion routes. Results: In the half-banded group, the impedance values in different modes CG, MP1, MP2, MP1 + 2 did not differ significantly among the surgical routes at all four electrodes. While in the full banded group, for CG mode impedance values at E5 differ significantly. Rest for other modes in full banded group, there was no statistically significant difference across the three routes. Conclusion: The present study supports that there is no statistically significant difference in the intraoperative impedance and ECAP measurements in both, the full-banded and half- banded electrodes across the three surgical routes implying that, all the three surgical approaches provide equal stimulation of the auditory nerve. The CI surgeon can select the electrode insertion portal based on the surgical anatomy, the implant type and individual preferences.
引用
收藏
页码:928 / 933
页数:5
相关论文
共 50 条
  • [1] Cochlear Implant Insertion Routes and Intra-operative Electrophysiological Measurements: A Retrospective Analysis at a Tertiary Care Centre
    Tadke, Kanchan
    Singh, Pradyumna
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2024, 76 (01) : 928 - 933
  • [2] Design of an Intra-Operative Imaging System for the Cochlear Implant
    Klafas, Calla
    McEwan, Alistair
    Carter, Paul
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 2448 - 2451
  • [3] The impact of intra-operative factors in otosclerosis outcomes: retrospective study in a tertiary centre
    Quaranta, N.
    Piccininni, K.
    Romanello, M.
    Lucidi, D.
    Sergi, B.
    ACTA OTORHINOLARYNGOLOGICA ITALICA, 2019, 39 (03) : 197 - 204
  • [4] Intra-operative cell salvage use in a tertiary orthopaedic centre
    Nathwani, R.
    Price, J.
    Kaur, J.
    ANAESTHESIA, 2013, 68 : 22 - 22
  • [5] Cochlear implant electrode array insertion monitoring with intra-operative 3D rotational X-ray
    Carelsen, B.
    Grolman, W.
    Tange, R.
    Streekstra, G. J.
    van, Kemenade P.
    Jansen, R. J.
    Freling, N. J. M.
    White, M.
    Maat, B.
    Fokkens, W. J.
    CLINICAL OTOLARYNGOLOGY, 2007, 32 (01) : 46 - 50
  • [6] Effect of cochlear implant electrode insertion on middle-ear function as measured by intra-operative laser Doppler vibrometry
    Donnelly, N.
    Bibas, A.
    Jiang, D.
    Bamiou, D-E
    Santulli, C.
    Jeronimidis, G.
    O'Connor, A. Fitzgerald
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2009, 123 (07): : 723 - 729
  • [7] Can you please come to theatre now? - A retrospective review of emergent intra-operative vascular assistance in a tertiary centre
    Narayanan, Anantha
    Naik, Ishan
    Khashram, Manar
    ANZ JOURNAL OF SURGERY, 2023, 93 (06) : 1461 - 1462
  • [8] Intra-operative skull X-ray for misdirection of the cochlear implant array into the vestibular labyrinth
    Hassan, A. M.
    Patel, R.
    Redleaf, M.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2015, 129 (09): : 923 - 927
  • [9] Diagnosis and management of intra-operative pulmonary embolism under general anaesthesia in a peripheral tertiary care centre with limited resources
    Sharma, Jagdeep
    Walia, Harsimran Singh
    Jaswal, Sofia
    Goyal, Atin
    INDIAN JOURNAL OF ANAESTHESIA, 2022, 66 : 131 - 132
  • [10] Diagnosis and management of intra-operative pulmonary embolism under general anaesthesia in a peripheral tertiary care centre with limited resources
    Sharma, Jagdeep
    Walia, Harsimran Singh
    Jaswal, Sofia
    Goyal, Atin
    INDIAN JOURNAL OF ANAESTHESIA, 2022, 66 (SUPPL 2) : S131 - S132