Design of an Intra-Operative Imaging System for the Cochlear Implant

被引:0
|
作者
Klafas, Calla [1 ]
McEwan, Alistair [1 ]
Carter, Paul [2 ]
机构
[1] Univ Sydney, Fac Engn & Informat Technol, Sch Elect & Informat Engn, Sydney, NSW 2006, Australia
[2] Cochlear Ltd, Sydney, NSW, Australia
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Research has shown that closer proximity of a cochlear implant electrode array to the inner modiolar wall can improve hearing performance in a recipient. It is understood that developing a real-time intra-operative imaging technique would bring the surgeon visual feedback that can correlate with tactile resistances during electrode insertion, reducing various risks of insertion traumas, while guiding the electrode for optimal placement. This paper presents the design of a 3-dimensional magnetic imaging system which provides a means for real-time imaging by reconstructing uniform segments of the electrode array's contours. In addition, the theoretical error of this reconstruction method is evaluated to select an optimal number of sensors within the electrode design. The theoretical error of the reconstruction method is evaluated for 7 to 22 inductive sensors within the electrode design. For 16 or more sensors, the error is improves to less than 0.5%. A working prototype was confirmed on a 10:1 scale with orthogonal Helmholtz coils at 85-115kHz.
引用
收藏
页码:2448 / 2451
页数:4
相关论文
共 50 条
  • [1] Design and development of a dedicated portable gamma camera system for intra-operative imaging
    Kaviani, Sanaz
    Zeraatkar, Navid
    Sajedi, Salar
    Akbarzadeh, Afshin
    Gorjizadeh, Nahid
    Farahani, Mohammad Hossein
    Teimourian, Behnoosh
    Ghafarian, Pardis
    Sabet, Hamid
    Ay, Mohammad Reza
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (07): : 889 - 897
  • [2] Design and performance of gamma and beta intra-operative imaging probes
    Hoffman, EJ
    Tornai, MP
    Levin, CS
    MacDonald, LR
    Siegel, S
    PHYSICA MEDICA, 1997, 13 : 243 - 246
  • [3] Intra-operative skull X-ray for misdirection of the cochlear implant array into the vestibular labyrinth
    Hassan, A. M.
    Patel, R.
    Redleaf, M.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2015, 129 (09): : 923 - 927
  • [4] Cochlear orientation: pre-operative evaluation and intra-operative significance
    Sharma, S.
    Grover, M.
    Singh, S. N.
    Kataria, T.
    Lakhawat, R. S.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2018, 132 (06): : 540 - 543
  • [5] INTRA-OPERATIVE RENAL CALCULUS IMAGING
    ROBERTS, SB
    UROLOGY, 1981, 18 (03) : 326 - 326
  • [6] Intra-operative imaging in trauma surgery
    Keil, Holger
    Beisemann, Nils
    Swartman, Benedict
    Vetter, Sven Yves
    Gruezner, Paul Alfred
    Franke, Jochen
    EFORT OPEN REVIEWS, 2018, 3 (10): : 541 - 549
  • [7] Automatic pre- to intra-operative CT registration for image-guided cochlear implant surgery
    Reda, Fitsum A.
    Dawant, Benoit M.
    Labadie, Robert F.
    Noble, Jack H.
    MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [8] Cochlear Implant Insertion Routes and Intra-operative Electrophysiological Measurements: A Retrospective Analysis at a Tertiary Care Centre
    Tadke, Kanchan
    Singh, Pradyumna
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2024, 76 (01) : 928 - 933
  • [9] Intra-operative identification of a temporal bone fracture line during cochlear implant surgery: a case report
    Gaelle Vofo
    Sagit Stern Shavit
    Ron Eliashar
    Michal Kaufmann
    BMC Pediatrics, 23
  • [10] Cochlear Implant Insertion Routes and Intra-operative Electrophysiological Measurements: A Retrospective Analysis at a Tertiary Care Centre
    Kanchan Tadke
    Pradyumna Singh
    Indian Journal of Otolaryngology and Head & Neck Surgery, 2024, 76 : 928 - 933