Dynamic in-vivo tibio-femoral and bearing motions in mobile bearing knee arthroplasty

被引:0
|
作者
S. Fantozzi
A. Leardini
S. A. Banks
M. Marcacci
S. Giannini
F. Catani
机构
[1] Istituti Ortopedici Rizzoli,Movement Analysis Laboratory
[2] University of Bologna,Department of Electronics, Computer Science and Systems
[3] The Biomotion Foundation,Department of Orthopaedic Surgery
[4] Istituti Ortopedici Rizzoli,undefined
关键词
Total knee arthroplasty; Mobile bearing tracking; Fluoroscopy; Prosthesis component kinematics; Activities of daily living;
D O I
暂无
中图分类号
学科分类号
摘要
To determine the tibio-femoral and bearing motions in well functioning mobile bearing total knee arthroplasties, a quantitative analysis by means of fluoroscopy was carried out during stair ascending, chair rising-sitting and step up-down motor tasks. Femoral and tibial component positions were obtained using a CAD-model-based shape matching technique. Direct measurement of mobile bearing motion was carried out by tracking previously inserted tantalum beads. A relatively small motion of the bearing was observed. The advantage of self-alignment claimed for the mobile bearing arthroplasty seems to be confirmed by subject-specific ranges of motion exhibited by these patients. It has also been demonstrated that these total knee arthroplasties, which are not fully conforming in flexion, provide little constraint to antero-posterior motion, leading to a kinematic pattern very similar to an ACL deficient knee.
引用
收藏
页码:144 / 151
页数:7
相关论文
共 50 条
  • [41] Lateral unicompartmental knee arthroplasty: Mobile and fixed bearing
    Walker T.
    Merle C.
    Gotterbarm T.
    Aldinger P.R.
    Arthroskopie, 2017, 30 (4) : 302 - 311
  • [42] Femoral Coronal Malalignment is Associated With Failure in Mobile-Bearing Medial Unicompartmental Knee Arthroplasty
    Lee, Sheng-Hsun
    Labott, Josh R.
    Perico, Diego Alarcon
    Perez, Sergio F. Guarin
    Sierra, Rafael J.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (08): : S59 - S64
  • [43] Fixed or mobile-bearing total knee arthroplasty
    Huang C.-H.
    Liau J.-J.
    Cheng C.-K.
    Journal of Orthopaedic Surgery and Research, 2 (1)
  • [44] Mobile-bearing unicompartmental knee arthroplasty (UKA)
    Berend, Keith R.
    Lombardi, Adolph V., Jr.
    ORTHOPEDICS, 2008, 31 (05) : S6 - S8
  • [45] Finite element analysis of in vivo tibio-femoral contact features with menisci
    Hao, Zhixiu
    Jin, Dewen
    Zhang, Jichuan
    Zhang, Yu
    Sun, Mingxue
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2008, 48 (02): : 176 - 179
  • [46] Development of an asymptotic modeling methodology for tibio-femoral contact in multibody dynamic simulations of the human knee joint
    Argatov, Ivan
    MULTIBODY SYSTEM DYNAMICS, 2012, 28 (1-2) : 3 - 20
  • [47] Predicting Knee Joint Instability Using a Tibio-Femoral Statistical Shape Model
    Cerveri, Pietro
    Belfatto, Antonella
    Manzotti, Alfonso
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2020, 8
  • [48] A finite element model of the human knee joint for the study of tibio-femoral contact
    Donahue, TLH
    Hull, ML
    Rashid, MM
    Jacobs, CR
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (03): : 273 - 280
  • [49] Mobile-Bearing Total Knee Arthroplasty Better Than a Fixed-Bearing?
    Post, Zachary D.
    Matar, Wadih Y.
    van de Leur, Tim
    Grossman, Eric L.
    Austin, Matthew S.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (06): : 998 - 1003
  • [50] Comparison of mobile bearing and fixed bearing total knee arthroplasty outcomes: A review of the literature
    Sykes J.
    Snearly C.
    Benner R.
    Bernard M.
    Mihalko W.M.
    Journal of ASTM International, 2011, 8 (02):